/*===================================================================*/ /* NRDF D1769 Data No.39 */ /*===================================================================*/ /* Bibliography */ /*===================================================================*/ \\BIB,39; D#=D1769; TITLE=/ Double-differential cross sections for the neutron production from heavy-ion reactions at energies E/A = 290-600 MeV /; PURPOSE=/ Systematic measurements of neutron-production cross sections from C, Ne, and Ar projectiles having E/A = 290-600 MeV on C, Cu, and Pb targets. /; ATH=(Y.IWATA'1', T.MURAKAMI'1', H.SATO'2', H.IWASE'2', T.NAKAMURA'2', T.KUROSAWA'2', L.HEILBRONN'3', R.M.RONNINGEN'4', K.IEKI'5', Y.TOZAWA'5', K.NIITA'6'); INST-ATH=(2JPNIRS'1', 2JPNTOH'2', 1USABRK'3', 1USAMSU'4', 2JPNRIK'5', 2JPNJPN'6'); /* '1' Department of Accelerator Physics and Engineering */ /* '2' Cyclotron and Radioisotope Center */ /* '4' National Superconducting Cyclotron Laboratory */ /* '5' Department of Physics */ /* '6' Research Organization for Information Science and Technology, Tokai, Naka, Ibaraki */ REF=PR/C; VLP=64(2001)054609; RCTS=(C(12C,N)X, CU(12C,N)X, PB(12C,N)X, C(20NE,N)X, CU(20NE,N)X, PB(20NE,N)X, C(40AR,N)X, CU(40AR,N)X, PB(40AR,N)X); PHQS=(ENGY-SPEC, ANGL-DSTRN, XSECTN, TOT-XSECTN, MLT); /*===================================================================*/ /* Experimental Conditions */ /*===================================================================*/ \\EXP,39; /* 2002-08-01 : Compiled, Am + Sr + On */ /* 2006-07-25 : Altered, On. Heading of data error corrected. Systematic uncertainties added. */ RTY=HEAVY-ION-RCT; ENR=NAT; CHM=ELM; PHYS-FORM=SLD; BAC=X; POL-TGT=0%; ALGN-TGT=0%; ACC=SYN'7'; /* '7' Heavy Ion Medical Accelerator in Chiba (HIMAC) facility INST-ACC=2JPNIRS; BEAM-INTNSTY=XMA'8'; /* '8' A few times 10e4-10e5 particles per pulse */ POL-PRJ=0%; DET-PARTCL=N; COINC=NO; ANT-COINC=NO; DET-SYS=(SCT'9',SCT'10',TOF); /* '9' NE102A plastic scintillator */ /* '10' NE213 liquid scintillator */ ERS-DET=XKEV'11'; /* '11' The energy resolutions are shown in Table I in reference. /* Experimental Method: - Time-of-flight RCT=PB(12C,N)X; PHQ=ENGY-SPEC; THK-TGT=9080MG/CM**2; INC-ENGY-LAB=400.0MEV/A; ANL=X'127'; /* '127' Moving-source model, QMD and HIC */ /*===================================================================*/ /* Descriptive Parameters */ /*===================================================================*/ \\DATA,39; SYS-ERR=10%'12'; /* '12' Uncertainty in detection efficiency */ INC-ENGY-LAB=400.0MEV/A; SYS-ERR=4.6%'128'; /* '128' Uncertainty in target thickness */ THTL=30DEG; /*===================================================================*/ /* Data Table */ /*===================================================================*/ \DATA; ENGY-EMT-LAB DSIGMA/DOMEGA/DE DELTA-DSIGMA/DOMEGA/DE'129' (MEV) (MB/SR/MEV) (MB/SR/MEV) 5 6762 +-418 6 921 +-59 7 427 +-27 8 260 +-21 9 208 +-16 10 149 +-15 15 76.9 +-3.5 25 44.2 +-2.5 35 33.0 +-2.1 45 27.5 +-1.9 55 25.2 +-1.7 65 23.8 +-1.9 75 21.2 +-1.7 85 21.5 +-1.9 95 18.2 +-1.8 105 15.6 +-1.7 125 17.5 +-1.2 145 13.6 +-1.1 165 11.1 +-0.9 185 8.54 +-0.83 205 7.43 +-0.76 235 7.92 +-0.60 265 4.21 +-0.45 295 5.32 +-0.43 325 3.34 +-0.35 365 3.43 +-0.31 405 2.14 +-0.22 465 1.05 +-0.15 525 0.495 +-0.096 605 0.278 +-0.055 725 9.28e-02 +-2.69e-02 885 2.32e-02 +-1.03e-02 1085 0.00e+00 +-3.93e-03 1285 0.00e+00 +-5.71e-03 1485 0.00e+00 +-8.76e-04 1685 0.00e+00 +-5.54e-03 1885 0.00e+00 +-4.26e-03 \END; /*===================================================================*/ |