DARPE: Search Results
 /*===================================================================*/
 /* NRDF D0816 Data No.4                                              */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,4;
 D#=D816;
 TITLE=/ Tensor analyzing powers of the proton continuum spectra from
         deuteron breakup at 56 MeV /;
 ATH=(N.MATSUOKA'1', K.HATANAKA'1', H.SAKAI'1', T.SAITO'1', K.HOSONO'1',
      T.ITAHASHI'1', A.SHIMIZU'1', M.KONDO'1', H.SAKAGUCHI'2',
      F.OHTANI'2');
 INST-ATH=(2JPNRCN'1', 2JPNKTO'2');
      /* '2' Department of Physics */
 REF=NP/A;
 VLP=408(1983)99;
 RCTS=(58NI(D,P)X, 90ZR(D,P)X);
 PHQS=(DBL-DIFF-XSECTN, TNSR-ANALPW);
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,4;
 /* 2007-08-24 : Converted, N.Otuka. Converted to EXFOR E0816 */
 CHM=ELM;
 PHYS-FORM=SLD;
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=CYC'3';
 /* '3' Isochronous cyclotron, AVF cyclotron */
 INST-ACC=2JPNRCN;
 INC-ENGY-LAB-RANGE=56MEV;
 BEAM-INTNSTY=5[40NA;
 POL-PRJ=70[80%;
 DET-PARTCL=P;
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=(SI'4',GE'4',SI'5',NAI'5',EDE);
 /* '4' To detect protons */
 /* '5' To detect protons (6, 8, 10, 13 deg) */
 RCT=58NI(D,P)X;
 PHQ=DBL-DIFF-XSECTN;
 ENR=99.8%;
 THK-TGT=3.79MG/CM**2;
 /* Data points lower than 20 MeV and higher than 45 MeV are mostly
    omitted because of high density of data points */
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,4;
 INC-ENGY-LAB=56MEV;
 STATIST-ERR=<2.5%'12';
 /* '12' Maximum statistical uncertainty (<2.5%) */
 THTL=13DEG;
 DELTA-DSIGMA/DOMEGA/DE=10%'13';
 /* '13' Uncertainty in absolute cross section, mainly due to
         uncertainty in target thickness */
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 ENGY-EMT-LAB DSIGMA/DOMEGA/DE
 (MEV) (MB/SR/MEV)
 1.8572E+01 1.237E+01
 1.9449E+01 1.489E+01
 2.0425E+01 1.819E+01
 2.1494E+01 1.974E+01
 2.2373E+01 2.343E+01
 2.3541E+01 2.595E+01
 2.4518E+01 3.002E+01
 2.5590E+01 3.273E+01
 2.6467E+01 3.545E+01
 2.7343E+01 3.739E+01
 2.8411E+01 3.854E+01
 2.9478E+01 3.893E+01
 3.0349E+01 3.833E+01
 3.1607E+01 3.735E+01
 3.2380E+01 3.618E+01
 3.3440E+01 3.364E+01
 3.4307E+01 3.072E+01
 3.5272E+01 2.877E+01
 3.6330E+01 2.526E+01
 3.7392E+01 2.311E+01
 3.8355E+01 2.019E+01
 3.9222E+01 1.785E+01
 4.0284E+01 1.589E+01
 4.1346E+01 1.355E+01
 4.2311E+01 1.160E+01
 4.3375E+01 1.101E+01
 4.4438E+01 9.636E+00
 4.5211E+01 8.463E+00
 \END;
 /*===================================================================*/