DARPE: Search Results
 /*===================================================================*/
 /* NRDF D1251 Data No.4                                              */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,4;
 D#=D1251;
 TITLE=/ Nuclear reactions of Ti, Fe, Co, Ni, Cu, and Zn by 500-MeV
         protons /;
 ATH=(Y.ASANO'1', S.MORI'1', M.SAKANO'1', K.KATOH'2', K.KONDO'2',
      M.NOGUCHI'2');
 INST-ATH=(2JPNTSU'1', 2JPNKEK'2');
      /* '1' Institute of Applied Physics */
 REF=JPJ;
 VLP=60(1991)107;
 RCTS=(TI(P,X)X, FE(P,X)X, 59CO(P,X)X, NI(P,X)X, CU(P,X)X, ZN(P,X)X);
 PHQS=XSECTN;
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,4;
 /* 2007-01-18 : Converted, N.Otuka. Converted to EXFOR E1251 */
 /* Related references 
    - T.Asano et al., PR/C, 28(1983)1718.
    (Cross section ratio of present data to this reference (at 12 GeV)
    discussed). See also NRDF D1243.
 PHQ=XSECTN;
 /* Additional results shown but not compiled
    - Mass distribution (Shown in Fig.1 and 3 in reference)
    - Charge distribution (Shown in Fig.2 in reference)
 ENR=NAT'3';
 /* '3' noen */
 CHM=ELM;
 PHYS-FORM=SLD;
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=SYN;
 INST-ACC=2JPNKEK;
 INC-ENGY-LAB-RANGE=500MEV;
 POL-PRJ=0%;
 DET-PARTCL=GAMMA'4';
 /* '4' Decay data not given */
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=GE(LI)'5';
 /* '5' To measure gamma rays */
 /* Experimental Method:
    - Stacked target irradiation (Stack of thin metal foils of 14
      elements)
    - Activation (Irradiated for 3 min)
    - Gamma ray spectrometry (Measured about 14 spectra during 7
      months)
 /* By authors: Measurements of short-lived nuclides with lifetimes
    shorter than a few hours could not be made. */
 RCT=FE(P,X)X'15';
 /* '15' See DATA section for atomic number (Z) and mass number
         (A) of products */
 THK-TGT=7.51MG/CM**2;
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,4;
 INC-ENGY-LAB=500MEV;
 TOT-ERR=X%'6';
 /* '6' Uncertainties in detection efficiency of gamma rays and
        statistical uncertainty for photo-yield (Uncertainties in beam
        intensity calibration are not included.) */
 SYS-ERR=(10%'7',15%'8');
 /* '7' Uncertainty in beam intensity calibration */
 /* '8' Maximum uncertainty in detection efficiency (15% below 200
        keV, 10% at 200-400 keV, 5% above 400 keV) */
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 Z A SIGMA'16' DELTA-SIGMA'16'
 (NODIM) (NODIM) (MB) (MB)
 11. 22 0.29 +-0.019
 11. 24 0.36 +-0.02
 19. 43 0.61 +-0.03
 21. 43 1.48 +-0.21
 21. 47 2.39 +-0.36
 23. 48 13.6 +-0.74
 24. 51 36.0 +-1.8
 25. 56 1.30 +-0.60
 27. 55 0.29 +-0.03
 27. 56 0.67 +-0.10
 27. 57 0.16 +-0.03
 \END;
 /*===================================================================*/