/*===================================================================*/ /* NRDF D1642 Data No.4 */ /*===================================================================*/ /* Bibliography */ /*===================================================================*/ \\BIB,4; D#=D1642; TITLE=/ Strong mutual excitation of 148Nd+20Ne /; PURPOSE=/ This paper reports a study of mutual excitation in acolliding system that contains stronger couplings between theelastic and inelastic channels /; ATH=(C.L.JIANG'1', S.KUBONO'1', N.IKEDA'1', M.TANAKA'1', H.KAWASHIMA'1', Y.FUCHI'1', I.KATAYAMA'1', T.NOMURA'1', S.C.PIEPER'2'); INST-ATH=(2JPNINS'1', 1USAANL'2'); /* '2' Physics Division */ REF=PL/B; VLP=259(1991)427; RCTS=148ND(20NE,20NE)148ND; PHQS=ANGL-DSTRN; /*===================================================================*/ /* Experimental Conditions */ /*===================================================================*/ \\EXP,4; /* 2003-10-02 : Converted, Kc + Am + On. Converted to EXFOR E1642 PHQ=ANGL-DSTRN; ENR=93.2%'3'; /* '3' The effect of other neodymium isotopes has been considered and eliminated. */ CHM=X'4'; /* '4' Enriched neodymium oxides */ PHYS-FORM=SLD; THK-TGT=[0.005MG/CM**2; BAC=C; THK-BAC=[0.010MG/CM**2; POL-TGT=0%; ALGN-TGT=0%; ACC=CYC'5'; /* '5' Sector-focussing cyclotron */ INST-ACC=2JPNINS; INC-ENGY-LAB=116.0MEV; BEAM-INTNSTY=1[2PNA; CHRG-INC-ION=7+; POL-PRJ=0%; ION-SOURCE=/ ECR (Electron Cyclotron Resonance) ion source [M.Sakiguchi et al., Proc. Intern. Conf. on ECR ion sources and their applications, NSCL report MSUR47, p323]. /; DET-PARTCL=20NE; COINC=NO; ANT-COINC=NO; DET-SYS=(MAG'6',SBD'7'); /* '6' Outgoing particles were analyzed magnetically and identified with the QDD magnet spectrometer together with a focal plane detector [S.Kato et al., Nucl. Instrum. Methods 154(1978)19. and M.Tanaka et al., Nucl. Instrum. Methods 195(1982)19.]. */ /* '7' Placed at 30 deg opposite to the spectrometer and served as a monitor in the angular distribution measurement. */ SOLID-ANGL=2.0MSR; ERS-DET=100[160KEV'8'; /* '8' Overall energy resolution in the measurement (depending measuring angle) */ ANL=CC'9'; /* '9' PTOLEMY [PTOLEMY, Argonne report ANL-76-11, Rev.1, unpublished] */ /* 2006-11-21 : Altered, At. Re-digitized */ RCT=148ND(20NE,20NE)148ND; RTY=INEL-SCATT; /*===================================================================*/ /* Descriptive Parameters */ /*===================================================================*/ \\DATA,4; INC-ENGY-LAB=116.0MEV; EXC-ENGY=0.301MEV; J-PTY=2+; EXC-ENGY-EMT=1.634MEV; J-PTY-EMT=2+; /*===================================================================*/ /* Data Table */ /*===================================================================*/ \DATA; THTC DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA (DEG) (MB/SR) (MB/SR) 3.213E+01 1.030E+02 +-1.125E+01 3.664E+01 8.610E+01 +-1.028E+01 4.115E+01 7.281E+01 +-9.902E+00 4.552E+01 7.851E+01 +-8.611E+00 4.761E+01 6.507E+01 +-9.694E+00 4.987E+01 6.717E+01 +-8.258E+00 5.204E+01 5.316E+01 +-8.465E+00 5.428E+01 3.577E+01 +-5.694E+00 5.646E+01 3.567E+01 +-4.625E+00 5.865E+01 4.087E+01 +-5.701E+00 6.073E+01 2.815E+01 +-4.205E+00 6.280E+01 1.708E+01 +-2.552E+00 6.723E+01 1.566E+01 +-2.645E+00 7.145E+01 5.828E+00 +-1.432E+00 \END; /*===================================================================*/ |