DARPE: Search Results
 /*===================================================================*/
 /* NRDF D1642 Data No.4                                              */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,4;
 D#=D1642;
 TITLE=/ Strong mutual excitation of 148Nd+20Ne /;
 PURPOSE=/ This paper reports a study of mutual excitation in
           acolliding system that contains stronger couplings between
           theelastic and inelastic channels /;
 ATH=(C.L.JIANG'1', S.KUBONO'1', N.IKEDA'1', M.TANAKA'1',
      H.KAWASHIMA'1', Y.FUCHI'1', I.KATAYAMA'1', T.NOMURA'1',
      S.C.PIEPER'2');
 INST-ATH=(2JPNINS'1', 1USAANL'2');
      /* '2' Physics Division */
 REF=PL/B;
 VLP=259(1991)427;
 RCTS=148ND(20NE,20NE)148ND;
 PHQS=ANGL-DSTRN;
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,4;
 /* 2003-10-02 : Converted, Kc + Am + On. Converted to EXFOR E1642
 PHQ=ANGL-DSTRN;
 ENR=93.2%'3';
 /* '3' The effect of other neodymium isotopes has been considered
        and eliminated. */
 CHM=X'4';
 /* '4' Enriched neodymium oxides */
 PHYS-FORM=SLD;
 THK-TGT=[0.005MG/CM**2;
 BAC=C;
 THK-BAC=[0.010MG/CM**2;
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=CYC'5';
 /* '5' Sector-focussing cyclotron */
 INST-ACC=2JPNINS;
 INC-ENGY-LAB=116.0MEV;
 BEAM-INTNSTY=1[2PNA;
 CHRG-INC-ION=7+;
 POL-PRJ=0%;
 ION-SOURCE=/ ECR (Electron Cyclotron Resonance) ion source
              [M.Sakiguchi et al., Proc. Intern. Conf. on ECR ion
              sources and their applications, NSCL report MSUR47,
              p323]. /;
 DET-PARTCL=20NE;
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=(MAG'6',SBD'7');
 /* '6' Outgoing particles were analyzed magnetically and
        identified with the QDD magnet spectrometer together with a
        focal plane detector [S.Kato et al., Nucl. Instrum. Methods
        154(1978)19. and M.Tanaka et al., Nucl. Instrum. Methods
        195(1982)19.]. */
 /* '7' Placed at 30 deg opposite to the spectrometer and served as
        a monitor in the angular distribution measurement. */
 SOLID-ANGL=2.0MSR;
 ERS-DET=100[160KEV'8';
 /* '8' Overall energy resolution in the measurement (depending
        measuring angle) */
 ANL=CC'9';
 /* '9' PTOLEMY [PTOLEMY, Argonne report ANL-76-11, Rev.1,
        unpublished] */
 /* 2006-11-21 : Altered, At. Re-digitized */
 RCT=148ND(20NE,20NE)148ND;
 RTY=INEL-SCATT;
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,4;
 INC-ENGY-LAB=116.0MEV;
 EXC-ENGY=0.301MEV;
 J-PTY=2+;
 EXC-ENGY-EMT=1.634MEV;
 J-PTY-EMT=2+;
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 THTC DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA
 (DEG) (MB/SR) (MB/SR)
 3.213E+01 1.030E+02 +-1.125E+01
 3.664E+01 8.610E+01 +-1.028E+01
 4.115E+01 7.281E+01 +-9.902E+00
 4.552E+01 7.851E+01 +-8.611E+00
 4.761E+01 6.507E+01 +-9.694E+00
 4.987E+01 6.717E+01 +-8.258E+00
 5.204E+01 5.316E+01 +-8.465E+00
 5.428E+01 3.577E+01 +-5.694E+00
 5.646E+01 3.567E+01 +-4.625E+00
 5.865E+01 4.087E+01 +-5.701E+00
 6.073E+01 2.815E+01 +-4.205E+00
 6.280E+01 1.708E+01 +-2.552E+00
 6.723E+01 1.566E+01 +-2.645E+00
 7.145E+01 5.828E+00 +-1.432E+00
 \END;
 /*===================================================================*/