 /* NRDF D1712 Data No.4                                              */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,4;
 D#=D1712;
 TITLE=/ Isovector electric monopole resonance in 60Ni /;
 PURPOSE=/ To report isovector electric monopole resonance (IVMR)
           excited by the (7Li,7Be) reaction on 60Ni. /;
 ATH=(S.NAKAYAMA'1', H.AKIMUNE'2,4', Y.ARIMOTO'2', I.DAITO'2',
      H.FUJIMURA'2', Y.FUJITA'3', M.FUJIWARA'2', K.FUSHIMI'1',
      H.KOHRI'2', N.KOORI'1', K.TASKAHISA'2', T.TAKEUCHI'4',
      M.TANAKA'6', T.YAMAGATA'4', Y.YAMAMOTO'4', K.YONEHARA'4',
      H.YOSHIDA'2');
 INST-ATH=(2JPNTKS'1', 2JPNRCN'2', 2JPNOSA'3', 2JPNKON'4', 2JPNTOK'5',
           2JPNKTJ'6');
      /* '1' Department of Physics */
      /* '3' Department of Physics */
      /* '4' Department of Physics */
      /* '5' Department of Physics */
 REF=PRL;
 VLP=83(1999)690;
 RCTS=60NI(7LI,7BE)60CO;
 PHQS=(ENGY-SPEC, ENGY-SPEC'7', RESN-ENGY, ANGL-DSTRN,
       DBL-DIFF-XSECTN);
 /* '7' countnumber difference between 0deg and 1deg */
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,4;
 /* 2002-08-08 : Converted, Ay + On. Data converted to EXFOR E1712
 ENR=99.9%;
 CHM=ELM;
 PHYS-FORM=SLD;
 THK-TGT=2.6MG/CM**2;
 BAC=SELF;
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=CYC;
 INST-ACC=2JPNRCN;
 INC-ENGY-LAB=65MEV/A;
 ERS-PRJ=XMEV;
 BEAM-INTNSTY=XNA;
 CHRG-INC-ION=+3;
 POL-PRJ=0%;
 DET-PARTCL=(GAMMA,7BE);
 COINC=(GAMMA,7BE);
 ANT-COINC=NO;
 DET-SYS=(MAG'8',SCT'9');
 /* '8' GRAND RAIDEN, to detect 7Be at 0.3 and 1 deg, see
        [M.Fujiwara et al., Nucl.Instrum.Methods
        Phys.Res.,Sect.A422(1999)484]. */
 /* '9' NYMPHS, GSO(Gd2SiO5:Ce) Scintillator, to detect 0.43MeV
        gamma ray from 7Be, see [S.Nakayama et al.,
        Nucl.Instrum.Methods Phys.Res.,Sect.A404(1998)34] */
 SOLID-ANGL=XMSR'10';
 /* '10' +-20mrad horizontally and +-15mrad vertically for GRAND
         RAIDEN. */
 /* 2006-07-20 : Altered, At. Re-digitized */
 RCT=60NI(7LI,7BE)60CO;
 PHQ=ENGY-SPEC;
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,4;
 INC-ENGY-LAB=65MEV/A;
 EMT-1=7BE;
 THTL-1=1DEG;
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 EXC-ENGY COUNTS'14'
 (MEV) (NODIM)
 7.826E+00 1.248E+03
 8.362E+00 1.410E+03
 8.847E+00 1.640E+03
 9.687E+00 1.428E+03
 1.077E+01 1.114E+03
 1.181E+01 7.673E+02
 1.290E+01 4.651E+02
 1.399E+01 3.366E+02
 1.502E+01 2.417E+02
 1.610E+01 2.364E+02
 1.718E+01 2.760E+02
 1.821E+01 2.707E+02
 1.929E+01 2.150E+02
 2.037E+01 2.210E+02
 2.145E+01 1.261E+02
 2.253E+01 1.208E+02
 2.356E+01 1.380E+02
 2.469E+01 1.103E+02
 2.573E+01 7.145E+01
 2.681E+01 1.110E+02
 2.789E+01 7.774E+01
 2.897E+01 4.447E+01
 3.005E+01 6.162E+01
 3.108E+01 8.436E+01
 3.221E+01 4.551E+01
 3.329E+01 5.146E+01
 3.432E+01 2.377E+01
 \END;
 /*===================================================================*/