DARPE: Search Results
 /*===================================================================*/
 /* NRDF D1921 Data No.4                                              */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,4;
 D#=D1921;
 TITLE=/ Activation cross-sections of long-lived products of
         proton-induced nuclear reactions on zinc /;
 ATH=(F.TARKANYI'1', F.DITROI'1', J.CSIKAI'1,2', S.TAKACS'1',
      M.S.UDDIN'3', M.HAGIWARA'3', M.BABA'3', YU.N.SHUBIN'4',
      A.I.DITYUK'4');
 INST-ATH=(3HUNDEB'1', 3HUNKOS'2', 2JPNTOH'3', 4RUSFEI'4');
      /* '2' Institute of Experimental Physics */
      /* '3' Cyclotron and Radioisotope Center */
 REF=ARI;
 VLP=62(2005)73;
 RCTS=(ZN(P,X)66GA, ZN(P,X)67GA, ZN(P,X)62ZN, ZN(P,X)65ZN,
       ZN(P,X)69ZN, ZN(P,X)64CU, ZN(P,X)57NI, ZN(P,X)55CO, ZN(P,X)56CO,
       ZN(P,X)57CO, ZN(P,X)58CO, ZN(P,X)60CO, ZN(P,X)52MN,
       ZN(P,X)54MN);
 PHQS=XSECTN;
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,4;
 /* 2005-07-01 : Compiled, Tk + On. */
 PHQ=XSECTN;
 ENR=NAT;
 CHM=ELM;
 PHYS-FORM=SLD'5';
 /* '5' Stacked with Cu (50 micro-meter) and Al (100 micro-meter)
        monitor foils */
 THK-TGT=XMG/CM**2'6';
 /* '6' 650 micro-meter */
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=CYC;
 INST-ACC=2JPNTOH'7';
 /* '7' Cyclotron and Radioisotope Center */
 POL-PRJ=0%;
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=HPGE'8';
 /* '8' To measure activity non-destructively */
 ANL=X'9';
 /* '9' ALICE-IPPE model code (A.I.Dityuk et al., 1998) */
 /* Experimental Method:
    - Activation
    - Stacked target irradiation (Prepared by inserting Zn target
      foils, Cu and Al monitor foils together in sequence)
    - Gamma ray spectrometry
 /* Related references 
    - M.Bonardi et al., JRC, 76(1983)311.
    Reference with which data agree. See also EXFOR O1062.000.
 RCT=ZN(P,X)65ZN;
 DET-PARTCL=GAMMA'23';
 /* '23' Delayed gamma from 65Zn */
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,4;
 SYS-ERR=(1%'10',7%'11',5%'12');
 /* '10' Uncertainty from foil thickness */
 /* '11' Uncertainty from incident proton flux */
 /* '12' Uncertainty from calculated detector efficiency */
 STATIST-ERR=10%'13';
 /* '13' Maximum uncertainty from the count rate determination of
         the photo peak areas of gamma-lines (1-10%) */
 ENGY-GAMMA=1115.5KEV'24';
 INTNSTY-GAMMA=0.5060'24';
 HALF-LIFE=244.06DAY'24';
 /* '24' Delayed gamma from 65Zn */
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 INC-ENGY-LAB DELTA-INC-ENGY-LAB XSECTN'25' DELTA-XSECTN'25'
 (MEV) (MEV) (MB) (MB)
 25.6 +-2.0 211 +-29
 33.1 +-1.7 132 +-18
 39.5 +-1.4 103 +-14
 45.1 +-1.2 116 +-16
 50.2 +-1.0 124 +-18
 54.9 +-0.8 122 +-17
 59.3 +-0.6 110 +-15
 63.4 +-0.5 106 +-14
 67.4 +-0.3 99 +-13
 \END;
 /*===================================================================*/