DARPE: Search Results
 /*===================================================================*/
 /* NRDF D1942 Data No.4                                              */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,4;
 D#=D1942;
 TITLE=/ Angular distributions of protons from the reaction
         12C(alpha,p)15N /;
 ATH=(I.NONAKA'1', H.YAMAGUCHI'1', T.MIKUMO'1', I.UMEDA'2', T.TABATA'2',
      S.HITAKA'3');
 INST-ATH=(2JPNINS'1', 2JPNKTO'2', 2JPNKYU'3');
 REF=JPJ;
 VLP=14(1959)1260;
 /* Secondary reference 
    - INS-J, 34(1960) (I.Nonaka et al., Numerical data)
 RCTS=12C(ALPHA,P)15N;
 PHQS=ANGL-DSTRN;
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,4;
 /* 2005-10-01 : Compiled, C.Kurokawa + N.Otuka */
 PHQ=ANGL-DSTRN;
 PHYS-FORM=SLD;
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=CYC;
 INST-ACC=2JPNINS;
 ERS-PRJ=0.5%;
 BEAM-INTNSTY=[0.1UA;
 POL-PRJ=0%;
 DET-PARTCL=P;
 COINC=NO;
 ANT-COINC=NO;
 RCT=12C(ALPHA,P)15N;
 CHM=ELM;
 THK-TGT=2.37MG/CM**2;
 BAC=SELF;
 INC-ENGY-LAB=25.0MEV;
 DET-SYS=NAI'30';
 /* '30' To detect proton */
 ERS-DET=5%;
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,4;
 SYS-ERR=(1[3%'4',[1%'5',[1%'6',[1%'7');
 /* '4' Uncertainty in background subtraction */
 /* '5' Uncertainty in the determination of mean target thickness,
        arising chiefly from the measurements of target areas for both
        polystyrene and carbon foil targets */
 /* '6' Uncertainty in the estimation of the beam current
        integration */
 /* '7' Uncertainty in the estimation of the detector solid angles
 STATIST-ERR=<10%'8';
 /* '8' Maximum statistical uncertainty (3-10%) */
 INC-ENGY-LAB=25.0MEV;
 EXC-ENGY=0.00MEV;
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 THTC DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'31'
 (DEG) (UB/SR) (UB/SR)
 12.9 378 +-13.8
 17.6 218 +-11.0
 23.4 97.4 +-7.0
 35.0 352 +-13.4
 46.5 542 +-17.0
 57.7 368 +-14.8
 68.8 200 +-11.0
 79.5 98.6 +-8.6
 89.9 166 +-14.2
 100.1 498 +-13.8
 109.9 726 +-20.4
 119.5 566 +-18.8
 128.8 346 +-15.6
 137.7 234 +-15.8
 146.5 594 +-23.2
 155.0 1332 +-36.2
 163.4 2116 +-46.4
 167.6 2446 +-50.4
 170.9 2652 +-55.4
 \END;
 /*===================================================================*/