DARPE: Search Results
 /*===================================================================*/
 /* NRDF D2019 Data No.4                                              */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,4;
 D#=D2019;
 TITLE=/ Heavy-ion reactions of Cu with 135 MeV/nucleon 12C /;
 ATH=(Y.K.KIM'1', J.C.KIM'1', C.-B.MOON'2', S.Y.CHO'3', Y.H.CHUNG'4',
      Y.OHKUBO'5');
 INST-ATH=(3KORNSU'1', 3KORKOR'2', 3KORYON'3', 3KORKOR'4',
           2JPNIPC'5');
      /* '1' Department of Physics */
      /* '2' Department of Physics, Hoseo University, Chonan */
      /* '3' Department of Industrial Hygiene */
      /* '4' Department of Chemistry, Hallym University, Chooncheon */
      /* '5' Radiochemistry Laboratory */
 REF=NP/A;
 VLP=578(1994)621;
 RCTS=CU(12C,X)X;
 PHQS=XSECTN;
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,4;
 /* 2006-12-20 : Compiled, K.Tsubakihara + N.Otuka */
 /* Related references 
    - U.Reus et al., AND, 29(1983)193.
    Reference from which data were used (Decay data)
 PHQ=XSECTN;
 /* Additional results shown but not compiled
    - Range of recoils measured (Forward range and
      forward-to-backward ratio)
 CHM=ELM;
 PHYS-FORM=SLD;
 THK-TGT=23.7MG/CM**2'6';
 /* '6' Surrounded by 10.5 mg/cm2-thick Mylar catcher foils */
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=CYC;
 INST-ACC=2JPNIPC'7';
 /* '7' RIKEN Accelerator Research Facility */
 INC-ENGY-LAB=134.5MEV/A;
 DELTA-INC-ENGY-LAB=1MEV/A;
 BEAM-INTNSTY=35NA'8';
 /* '8' +-10 nA */
 POL-PRJ=0%;
 DET-PARTCL=GAMMA'9';
 /* '9' Decay data not given */
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=GE'10';
 /* '10' To measure gamma-ray of separated foils */
 /* Experimental Method:
    - Activation (Irradiated for 10 min for shout half-life (<24 h)
      nuclides and for 2 hours (for longer half-life nuclides))
    - Gamma ray spectrometry
 /* Data given are weighted average of separate determinations
    (short/long irradiations, several gamma-rays) */
 RCT=CU(12C,X)X'21';
 /* '21' See DATA section for atomic number (Z) and mass number
         (A) of products */
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,4;
 INC-ENGY-LAB=134.5MEV/A;
 DELTA-INC-ENGY-LAB=1MEV/A;
 SYS-ERR=(5%'11',5%'12');
 /* '11' Uncertainty in detector-efficiency calibration */
 /* '12' Uncertainty in single determination of single gamma-ray
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 Z A ISOMER SIGMA'' DELTA-SIGMA',22'
 (NODIM) (NODIM) (NODIM) (MB) (MB)
 27. 58 0 54.6 +-6.0
 27. 60 0 18.3 +-3.0
 \END;
 /*===================================================================*/