DARPE: Search Results
 /*===================================================================*/
 /* NRDF D1434 Data No.41                                             */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,41;
 D#=D1434;
 TITLE=/Nuclear structure of even lead isotopes by the (p,t) reaction/;
 ATH=(M.TAKAHASHI'1', T.MURAKAMI'1', S.MORITA'1', H.ORIHARA'2',
      Y.ISHIZAKI'3', H.YAMAGUCHI'4');
 INST-ATH=(2JPNTOH'1', 2JPNTOH'2', 2JPNINS'3', 2JPNTKS'4');
      /* '1' Department of Physics */
      /* '2' Cyclotron and Radioisotope Center */
      /* '3' Institute for Nuclear Study */
      /* '4' Faculty of General Education */
 REF=PR/C;
 VLP=27(1983)1454;
 RCTS=(208PB(P,T)206PB, 206PB(P,T)204PB, 204PB(P,T)202PB);
 PHQS=ANGL-DSTRN;
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,41;
 /* 2003-10-24 : Converted, Data converted to EXFOR E1434 and EXFOR
    O0685 */
 PHQ=ANGL-DSTRN;
 ENR=>99%;
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=SYNCYC;
 INST-ACC=2JPNINS;
 INC-ENGY-LAB=51.9MEV;
 POL-PRJ=0%;
 DET-PARTCL=T;
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=(MAG'5',PROP-CNTR'6',SCT);
 /* '5' To analyze triton momentum */
 /* '6' Array of 200 proportional counters serve as position
        detectors. They form counter telescopes in combination with
        scintillation counters. */
 ERS-DET=[90KEV'7';
 /* '7' Overall energy resolution for the tritons of interest */
 ANL=DWBA'8';
 /* '8' Zero-range DWBA approximation (code DWUCK-4, [W.A.Lanford
        and J.B.McGrory, Michigan State University Cyclotron Laboratory
        Report No.MSUCL-81, 1973 (unpublished); Phys. Lett.
        45B(1973)283]) */
 RCT=204PB(P,T)202PB;
 CHM=ELM'190';
 /* '190' Prepared by centrifugal settling of PbO */
 PHYS-FORM=SLD;
 THK-TGT=2MG/CM**2;
 BAC=MYLAR;
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,41;
 INC-ENGY-LAB=51.9MEV;
 SYS-ERR=<20%'191';
 /* '191' Error of the absolute cross section of the ground state
          transition is estimated to be less than 20%, where the main
          part comes from the uncertainty of the solid angle of each
          counter on the focal plane of the magnetic spectrograph. */
 EMT=T;
 RSD=202PB;
 EXC-ENGY=2.73MEV;
 J-PTY=6+;
 DELTA-THTC=0.25DEG'192';
 /* '192' Data-point reader uncertainty */
 DELTA-DSIGMA/DOMEGA=1.9%'193';
 /* '193' Data-point reader uncertainty */
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 THTC DSIGMA/DOMEGA
 (DEG) (UB/SR)
 5.96           281.
 6.72           310.
 8.46           320.
 10.41          325.
 12.36          317.
 15.52          249.
 18.11          186.
 20.11          136.
 22.91          91.6
 25.67          77.5
 28.22          69.4
 30.94          71.6
 33.12          57.2
 35.66          56.5
 38.44          42.
 41.            35.
 45.75          25.
 51.23          20.6
 55.78          13.55
 61.08          9.97
 \END;
 /*===================================================================*/