/*===================================================================*/ /* NRDF D0682 Data No.44 */ /*===================================================================*/ /* Bibliography */ /*===================================================================*/ \\BIB,44; D#=D682; TITLE=/Elastic scattering of 56 MeV polarized deuterons from complex nuclei/; ATH=(K.HATANAKA'1', K.IMAI'2', S.KOBAYASHI'2', T.MATSUSUE'2', M.NAKAMURA'2', K.NISIMURA'2', T.NORO'2', H.SAKAMOTO'2', H.SHIMIZU'2', J.SHIRAI'2'); INST-ATH=(2JPNRCN'1', 2JPNKTO'2'); /* '2' Department of Physics */ REF=NP/A; VLP=340(1980)93; RCTS=(16O(D,D)16O, 24MG(D,D)24MG, 28SI(D,D)28SI, 32S(D,D)32S, 40AR(D,D)40AR, 40CA(D,D)40CA, 44CA(D,D)44CA, 54FE(D,D)54FE, 58NI(D,D)58NI, 60NI(D,D)60NI, 64NI(D,D)64NI, 90ZR(D,D)90ZR, 118SN(D,D)118SN, 208PB(D,D)208PB); PHQS=(ANGL-DSTRN, ANALPW, SPIN-CORRL-PARA, OPT-POTL-PARA); /*===================================================================*/ /* Experimental Conditions */ /*===================================================================*/ \\EXP,44; /* 2004-11-24 : Converted, Converted to EXFOR E682 */ RTY=ELA-SCATT; BAC=SELF'3'; /* '3' for solid target (foil) */ ACC=CYC'4'; /* '4' Isochronous cyclotron, AVF cyclotron */ INST-ACC=2JPNRCN; INC-ENGY-LAB=56MEV; DELTA-INC-ENGY-LAB=XKEV; ERS-PRJ=XKEV; BEAM-INTNSTY=5[20NA; POL-PRJ=[75%'5'; /* '5' 70-80% */ ION-SOURCE=/ Atomic beam source (See Table 1 in p95 of reference for detail.) /; DET-PARTCL=D; COINC=NO; ANT-COINC=NO; DET-SYS=(SI'6',HPGE'7',NAI'8',EDE); /* '6' To detect deuteron, transmission type */ /* '7' To detect deuteron, cooled by liquid nitrogen */ /* '8' To monitor beam current and polarization, NaI (Tl) scintillator */ ERS-DET=200KEV; ANL=OPT-MODEL'9'; /* '9' With and without tensor potentials */ /* Experimental Method: - Particle identification by 'E/Delta E' measurement RCT=64NI(D,D)64NI; PHQ=SPIN-CORRL-PARA; ENR=96.48%; CHM=ELM; PHYS-FORM=SLD; THK-TGT=2.34MG/CM**2; /*===================================================================*/ /* Descriptive Parameters */ /*===================================================================*/ \\DATA,44; INC-ENGY-LAB=56MEV; RSD=64NI; DELTA-DSIGMA/DOMEGA=10%'151'; /* '151' Uncertainty due to normalization of analyzing power of carbon polarimeter */ /*===================================================================*/ /* Data Table */ /*===================================================================*/ \DATA; THTC AXX DELTA-AXX'152' (DEG) (NODIM) (NODIM) 13.42 -0.037 0.021 14.45 0.029 0.022 15.48 0.052 0.015 17.54 -0.006 0.020 19.60 -0.044 0.019 20.64 -0.075 0.010 21.67 -0.084 0.021 23.21 -0.125 0.024 23.73 -0.080 0.037 25.78 -0.159 0.042 27.84 0.113 0.062 28.36 0.027 0.031 29.90 -0.062 0.022 30.93 -0.089 0.015 31.96 -0.206 0.032 34.53 -0.429 0.070 37.09 -0.757 0.089 39.66 0.280 0.043 42.22 0.117 0.043 44.78 0.018 0.036 46.31 -0.098 0.053 53.97 0.024 0.057 59.07 0.085 0.063 64.15 0.027 0.060 69.22 -0.054 0.068 \END; /*===================================================================*/ |