DARPE: Search Results
 /*===================================================================*/
 /* NRDF D1434 Data No.46                                             */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,46;
 D#=D1434;
 TITLE=/Nuclear structure of even lead isotopes by the (p,t) reaction/;
 ATH=(M.TAKAHASHI'1', T.MURAKAMI'1', S.MORITA'1', H.ORIHARA'2',
      Y.ISHIZAKI'3', H.YAMAGUCHI'4');
 INST-ATH=(2JPNTOH'1', 2JPNTOH'2', 2JPNINS'3', 2JPNTKS'4');
      /* '1' Department of Physics */
      /* '2' Cyclotron and Radioisotope Center */
      /* '3' Institute for Nuclear Study */
      /* '4' Faculty of General Education */
 REF=PR/C;
 VLP=27(1983)1454;
 RCTS=(208PB(P,T)206PB, 206PB(P,T)204PB, 204PB(P,T)202PB);
 PHQS=ANGL-DSTRN;
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,46;
 /* 2003-10-24 : Converted, Data converted to EXFOR E1434 and EXFOR
    O0685 */
 PHQ=ANGL-DSTRN;
 ENR=>99%;
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=SYNCYC;
 INST-ACC=2JPNINS;
 INC-ENGY-LAB=51.9MEV;
 POL-PRJ=0%;
 DET-PARTCL=T;
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=(MAG'5',PROP-CNTR'6',SCT);
 /* '5' To analyze triton momentum */
 /* '6' Array of 200 proportional counters serve as position
        detectors. They form counter telescopes in combination with
        scintillation counters. */
 ERS-DET=[90KEV'7';
 /* '7' Overall energy resolution for the tritons of interest */
 ANL=DWBA'8';
 /* '8' Zero-range DWBA approximation (code DWUCK-4, [W.A.Lanford
        and J.B.McGrory, Michigan State University Cyclotron Laboratory
        Report No.MSUCL-81, 1973 (unpublished); Phys. Lett.
        45B(1973)283]) */
 RCT=208PB(P,T)206PB;
 CHM=ELM;
 PHYS-FORM=SLD'212';
 /* '212' Metallic foil */
 THK-TGT=4MG/CM**2;
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,46;
 INC-ENGY-LAB=51.9MEV;
 SYS-ERR=<20%'213';
 /* '213' Error of the absolute cross section of the ground state
          transition is estimated to be less than 20%, where the main
          part comes from the uncertainty of the solid angle of each
          counter on the focal plane of the magnetic spectrograph. */
 EMT=T;
 RSD=206PB;
 EXC-ENGY=5.1MEV;
 J-PTY=7-;
 DELTA-THTC=0.25DEG'214';
 /* '214' Data-point reader uncertainty */
 DELTA-DSIGMA/DOMEGA=1.9%'215';
 /* '215' Data-point reader uncertainty */
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 THTC DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'216'
 (DEG) (UB/SR) (%)
 5.98           11.83          +-X
 9.02           15.27          +-X
 11.54          15.1           +-X
 13.9           12.08          +-X
 16.24          11.63          +-X
 18.6           9.81           +-X
 21.51          6.43           +-X
 23.84          7.46           +-X
 25.86          5.58           +-3.
 28.56          4.65           +-6.
 33.61          4.2            +-12.
 38.86          3.4            +-15.
 43.43          1.4            +-40.
 48.65          1.5            +-40.
 53.37          0.91           +-29.
 58.63          0.56           +-50.
 63.31          0.53           +-50.
 \END;
 /*===================================================================*/