DARPE: Search Results
 /*===================================================================*/
 /* NRDF D1769 Data No.49                                             */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,49;
 D#=D1769;
 TITLE=/ Double-differential cross sections for the neutron
         production from heavy-ion reactions at energies E/A = 290-600
         MeV /;
 PURPOSE=/ Systematic measurements of neutron-production cross
           sections from C, Ne, and Ar projectiles having E/A = 290-600
           MeV on C, Cu, and Pb targets. /;
 ATH=(Y.IWATA'1', T.MURAKAMI'1', H.SATO'2', H.IWASE'2', T.NAKAMURA'2',
      T.KUROSAWA'2', L.HEILBRONN'3', R.M.RONNINGEN'4', K.IEKI'5',
      Y.TOZAWA'5', K.NIITA'6');
 INST-ATH=(2JPNIRS'1', 2JPNTOH'2', 1USABRK'3', 1USAMSU'4', 2JPNRIK'5',
           2JPNJPN'6');
      /* '1' Department of Accelerator Physics and Engineering */
      /* '2' Cyclotron and Radioisotope Center */
      /* '4' National Superconducting Cyclotron Laboratory */
      /* '5' Department of Physics */
      /* '6' Research Organization for Information Science and
              Technology, Tokai, Naka, Ibaraki */
 REF=PR/C;
 VLP=64(2001)054609;
 RCTS=(C(12C,N)X, CU(12C,N)X, PB(12C,N)X, C(20NE,N)X, CU(20NE,N)X,
       PB(20NE,N)X, C(40AR,N)X, CU(40AR,N)X, PB(40AR,N)X);
 PHQS=(ENGY-SPEC, ANGL-DSTRN, XSECTN, TOT-XSECTN, MLT);
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,49;
 /* 2002-08-01 : Compiled, Am + Sr + On */
 /* 2006-07-25 : Altered, On. Heading of data error corrected.
    Systematic uncertainties added. */
 RTY=HEAVY-ION-RCT;
 ENR=NAT;
 CHM=ELM;
 PHYS-FORM=SLD;
 BAC=X;
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=SYN'7';
 /* '7' Heavy Ion Medical Accelerator in Chiba (HIMAC) facility
 INST-ACC=2JPNIRS;
 BEAM-INTNSTY=XMA'8';
 /* '8' A few times 10e4-10e5 particles per pulse */
 POL-PRJ=0%;
 DET-PARTCL=N;
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=(SCT'9',SCT'10',TOF);
 /* '9' NE102A plastic scintillator */
 /* '10' NE213 liquid scintillator */
 ERS-DET=XKEV'11';
 /* '11' The energy resolutions are shown in Table I in reference.
 /* Experimental Method:
    - Time-of-flight
 RCT=C(20NE,N)X;
 PHQ=ENGY-SPEC;
 THK-TGT=1800MG/CM**2;
 INC-ENGY-LAB=400.0MEV/A;
 ANL=X'157';
 /* '157' Moving-source model, QMD and HIC */
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,49;
 SYS-ERR=10%'12';
 /* '12' Uncertainty in detection efficiency */
 INC-ENGY-LAB=400.0MEV/A;
 SYS-ERR=6.8%'158';
 /* '158' Uncertainty in target thickness */
 THTL=80DEG;
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 ENGY-EMT-LAB DSIGMA/DOMEGA/DE DELTA-DSIGMA/DOMEGA/DE'159'
 (MEV) (MB/SR/MEV) (MB/SR/MEV)
 5 2.95 +-1.86
 6 3.44 +-1.29
 7 2.46 +-1.16
 8 2.46 +-1.12
 9 4.92 +-0.94
 10 1.97 +-0.86
 20 1.87 +-0.21
 40 1.35 +-0.17
 60 0.689 +-0.137
 80 0.664 +-0.149
 100 0.517 +-0.112
 120 0.443 +-0.081
 140 0.295 +-0.089
 160 0.172 +-0.059
 180 0.148 +-0.048
 200 0.123 +-0.046
 230 4.92e-02 +-2.41e-02
 260 1.64e-02 +-1.43e-02
 290 0.00e+00 +-5.13e-03
 320 3.28e-02 +-1.94e-02
 360 0.00e+00 +-4.96e-03
 400 0.00e+00 +-7.36e-03
 460 1.64e-02 +-1.63e-02
 520 0.00e+00 +-2.11e-02
 600 0.00e+00 +-1.80e-03
 720 0.00e+00 +-1.14e-02
 880 3.08e-03 +-6.87e-03
 1080 2.46e-03 +-2.84e-03
 1280 2.46e-03 +-1.99e-03
 1480 2.46e-03 +-1.76e-03
 1680 0.00e+00 +-1.66e-03
 1880 0.00e+00 +-4.38e-04
 \END;
 /*===================================================================*/