DARPE: Search Results
 /*===================================================================*/
 /* NRDF D0816 Data No.5                                              */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,5;
 D#=D816;
 TITLE=/ Tensor analyzing powers of the proton continuum spectra from
         deuteron breakup at 56 MeV /;
 ATH=(N.MATSUOKA'1', K.HATANAKA'1', H.SAKAI'1', T.SAITO'1', K.HOSONO'1',
      T.ITAHASHI'1', A.SHIMIZU'1', M.KONDO'1', H.SAKAGUCHI'2',
      F.OHTANI'2');
 INST-ATH=(2JPNRCN'1', 2JPNKTO'2');
      /* '2' Department of Physics */
 REF=NP/A;
 VLP=408(1983)99;
 RCTS=(58NI(D,P)X, 90ZR(D,P)X);
 PHQS=(DBL-DIFF-XSECTN, TNSR-ANALPW);
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,5;
 /* 2007-08-24 : Converted, N.Otuka. Converted to EXFOR E0816 */
 CHM=ELM;
 PHYS-FORM=SLD;
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=CYC'3';
 /* '3' Isochronous cyclotron, AVF cyclotron */
 INST-ACC=2JPNRCN;
 INC-ENGY-LAB-RANGE=56MEV;
 BEAM-INTNSTY=5[40NA;
 POL-PRJ=70[80%;
 DET-PARTCL=P;
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=(SI'4',GE'4',SI'5',NAI'5',EDE);
 /* '4' To detect protons */
 /* '5' To detect protons (6, 8, 10, 13 deg) */
 RCT=58NI(D,P)X;
 PHQ=DBL-DIFF-XSECTN;
 ENR=99.8%;
 THK-TGT=3.79MG/CM**2;
 /* Data points lower than 20 MeV and higher than 45 MeV are mostly
    omitted because of high density of data points */
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,5;
 INC-ENGY-LAB=56MEV;
 STATIST-ERR=<2.5%'14';
 /* '14' Maximum statistical uncertainty (<2.5%) */
 THTL=20DEG;
 DELTA-DSIGMA/DOMEGA/DE=10%'15';
 /* '15' Uncertainty in absolute cross section, mainly due to
         uncertainty in target thickness */
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 ENGY-EMT-LAB DSIGMA/DOMEGA/DE
 (MEV) (MB/SR/MEV)
 1.8659E+01 7.512E+00
 1.9533E+01 8.671E+00
 2.0503E+01 8.858E+00
 2.1569E+01 9.044E+00
 2.2541E+01 1.040E+01
 2.3608E+01 1.136E+01
 2.4579E+01 1.233E+01
 2.5454E+01 1.348E+01
 2.6522E+01 1.445E+01
 2.7396E+01 1.561E+01
 2.8560E+01 1.638E+01
 2.9432E+01 1.617E+01
 3.0498E+01 1.617E+01
 3.1369E+01 1.558E+01
 3.2337E+01 1.498E+01
 3.3401E+01 1.420E+01
 3.4368E+01 1.341E+01
 3.5336E+01 1.282E+01
 3.6399E+01 1.126E+01
 3.7364E+01 9.499E+00
 3.8331E+01 8.519E+00
 3.9395E+01 7.538E+00
 4.0556E+01 6.556E+00
 4.1330E+01 5.772E+00
 4.2491E+01 4.790E+00
 4.3362E+01 4.589E+00
 4.4233E+01 3.998E+00
 4.5201E+01 3.213E+00
 \END;
 /*===================================================================*/