DARPE: Search Results
 /*===================================================================*/
 /* NRDF D1242 Data No.5                                              */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,5;
 D#=D1242;
 TITLE=/ Nuclear reactions of 48Ti, 56Fe, 57Fe, 58Ni, 60Ni, 63Cu, and
         65Cu by 12-GeV protons /;
 ATH=(M.NOGUCHI'1', H.HIRABAYASHI'1', K.KATOH'1', K.KONDO'1',
      M.TAKASAKI'1', Y.ASANO'2', S.MORI'2', M.SAKANO'2');
 INST-ATH=(2JPNKEK'1', 2JPNTSU'2');
      /* '2' Institute of Applied Physics */
 REF=PR/C;
 VLP=38(1988)1811;
 RCTS=(48TI(P,X)X, 56FE(P,X)X, 57FE(P,X)X, 58NI(P,X)X, 60NI(P,X)X,
       63CU(P,X)X, 65CU(P,X)X);
 PHQS=XSECTN;
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,5;
 /* 2007-01-18 : Converted, N.Otuka. Converted to EXFOR E1242 */
 PHQ=XSECTN;
 /* Additional results shown but not compiled
    - Charge distribution (Shown in Fig.6 in reference)
 PHYS-FORM=SLD;
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=SYN;
 INST-ACC=2JPNKEK;
 INC-ENGY-LAB-RANGE=12GEV;
 POL-PRJ=0%;
 DET-PARTCL=GAMMA'3';
 /* '3' Decay data not given */
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=GE(LI)'4';
 /* '4' For gamma-ray spectroscopy */
 /* Experimental Method:
    - Stacked target irradiation
    - Activation (Irradiated for 14 min)
    - Gamma ray spectrometry (Performed during 3 months starting
      about 4 hours after the end of irradiation. In addition 56Fe and
      57Fe targets were measured about 15 months after irradiation.)
 /* By authors: Measurements of short-lived nuclides with lifetimes
    much shorter than a few hours were precluded. */
 RCT=57FE(P,X)X'16';
 /* '16' See DATA section for atomic number (Z) and mass number
         (A) of products */
 ENR=90.68%;
 CHM=FE2.O3;
 THK-TGT=10MG/CM**2;
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,5;
 INC-ENGY-LAB=12GEV;
 TOT-ERR=X%'5';
 /* '5' Uncertainty in detection efficiency of gamma rays and
        statistical errors for photopeak yields (Uncertainties in
        normalization are not included.) */
 SYS-ERR=(10%'6',15%'7');
 /* '6' Uncertainty in beam intensity calibration */
 /* '7' Maximum uncertainty in detection efficiency (15% below 200
        keV, 10% at 200-400 keV, 5% above 400 keV) */
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 Z A ISOMER SIGMA',17' DELTA-SIGMA''
 (NODIM) (NODIM) (NODIM) (MB) (MB)
 19. 42 X 3.7 +-0.3
 21. 44 0 2.9 +-0.18
 21. 44 1 3.7 +-0.2
 21. 46 X 6.1 +-0.3
 21. 48 X 0.56 +-0.06
 24. 48 X 0.12 +-0.01
 25. 52 X 2.6 +-0.14
 25. 54 X 23 +-1.2
 27. 58 X 0.20 +-0.02
 \END;
 /*===================================================================*/