DARPE: Search Results
 /*===================================================================*/
 /* NRDF D1498 Data No.5                                              */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,5;
 D#=D1498;
 TITLE=/ Determination of the astrophysical 13N(p,gamma)14O cross
         section through the Coulomb dissociation method /;
 PURPOSE=/ To determine 13N(p,gamma)140 reaction in hot CNO cycle /;
 ATH=(T.MOTOBAYASHI'1', T.TAKEI'1', S.KOX'2', C.PERRIN'2', F.MERCHEZ'2',
      D.REBREYEND'2', K.IEKI'1', H.MURAKAMI'1', Y.ANDO'1', N.IWASA'1',
      M.KUROKAWA'1', S.SHIRATO'1', J.RUAN'1', T.ICHIHARA'3', T.KUBO'3',
      N.INABE'3', A.GOTO'3', S.KUBONO'4', S.SHIMOURA'5', M.ISHIHARA'3,
     5');
 INST-ATH=(2JPNRIK'1', 2FR GRE'2', 2JPNIPC'3', 2JPNINS'4',
           2JPNTOK'5');
      /* '1' Department of Physics */
      /* '2' Institut des Sciences Nucleaires */
      /* '5' Department of Physics */
 REF=PL/B;
 VLP=264(1991)259;
 RCTS=(208PB(14O,14O)208PB, 208PB(13N,13N)208PB, 13N(P,GAMMA)14O,
       12C(P,GAMMA)13N);
 PHQS=(ENGY-SPEC, ANGL-DSTRN, RESN-WDTH, REDUCED-WDTH);
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,5;
 /* 2005-11-24 : Converted, C.Kurokawa + N.Otuka. Converted to
    EXFOR E1498 */
 CHM=ELM;
 PHYS-FORM=SLD;
 THK-TGT=350MG/CM**2;
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=(CYC'6',PRJFS'7');
 /* '6' To accelerate primary 16O beam to 135 MeV/A */
 /* '7' To separate secondary 14O beam from 9Be production target
 INST-ACC=(2JPNIPC,2JPNIPC);
 ERS-PRJ=1%;
 BEAM-INTNSTY=XNA'8';
 /* '8' 3*1e4 per sec. for 14O beam, unknown for 13N beam */
 POL-PRJ=0%;
 ANT-COINC=NO;
 DET-SYS=(CNTR-TLSCP'9',SI'9',CSI'9',SCT'10',EDE);
 /* '9' To detect heavy ions and coincident protons (EMRIC) */
 /* '10' Plastic scintillator hodoscope */
 /* Related references 
    - G.R.Gaughlan et al., AND, 40(1988)283.
    Reference with which data disagree (This work recommends 1.9 eV,
    smaller than the present work)
    - P.B.Fernandez et al., PR/C, 40(1989)1887.
    Reference with which data agree (This work gives 2.7+-1.3 eV,
    consistent with the present work)
 RCT=13N(P,GAMMA)14O;
 PHQ=RESN-WDTH;
 COINC=NO;
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,5;
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 EXC-ENGY RESN-WDTH DELTA-RESN-WDTH'16'
 (MEV) (EV) (EV)
 5.17 3.1 +-0.6
 \END;
 /*===================================================================*/