DARPE: Search Results
 /*===================================================================*/
 /* NRDF D1642 Data No.5                                              */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,5;
 D#=D1642;
 TITLE=/ Strong mutual excitation of 148Nd+20Ne /;
 PURPOSE=/ This paper reports a study of mutual excitation in
           acolliding system that contains stronger couplings between
           theelastic and inelastic channels /;
 ATH=(C.L.JIANG'1', S.KUBONO'1', N.IKEDA'1', M.TANAKA'1',
      H.KAWASHIMA'1', Y.FUCHI'1', I.KATAYAMA'1', T.NOMURA'1',
      S.C.PIEPER'2');
 INST-ATH=(2JPNINS'1', 1USAANL'2');
      /* '2' Physics Division */
 REF=PL/B;
 VLP=259(1991)427;
 RCTS=148ND(20NE,20NE)148ND;
 PHQS=ANGL-DSTRN;
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,5;
 /* 2003-10-02 : Converted, Kc + Am + On. Converted to EXFOR E1642
 PHQ=ANGL-DSTRN;
 ENR=93.2%'3';
 /* '3' The effect of other neodymium isotopes has been considered
        and eliminated. */
 CHM=X'4';
 /* '4' Enriched neodymium oxides */
 PHYS-FORM=SLD;
 THK-TGT=[0.005MG/CM**2;
 BAC=C;
 THK-BAC=[0.010MG/CM**2;
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=CYC'5';
 /* '5' Sector-focussing cyclotron */
 INST-ACC=2JPNINS;
 INC-ENGY-LAB=116.0MEV;
 BEAM-INTNSTY=1[2PNA;
 CHRG-INC-ION=7+;
 POL-PRJ=0%;
 ION-SOURCE=/ ECR (Electron Cyclotron Resonance) ion source
              [M.Sakiguchi et al., Proc. Intern. Conf. on ECR ion
              sources and their applications, NSCL report MSUR47,
              p323]. /;
 DET-PARTCL=20NE;
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=(MAG'6',SBD'7');
 /* '6' Outgoing particles were analyzed magnetically and
        identified with the QDD magnet spectrometer together with a
        focal plane detector [S.Kato et al., Nucl. Instrum. Methods
        154(1978)19. and M.Tanaka et al., Nucl. Instrum. Methods
        195(1982)19.]. */
 /* '7' Placed at 30 deg opposite to the spectrometer and served as
        a monitor in the angular distribution measurement. */
 SOLID-ANGL=2.0MSR;
 ERS-DET=100[160KEV'8';
 /* '8' Overall energy resolution in the measurement (depending
        measuring angle) */
 ANL=CC'9';
 /* '9' PTOLEMY [PTOLEMY, Argonne report ANL-76-11, Rev.1,
        unpublished] */
 /* 2006-11-21 : Altered, At. Re-digitized */
 RCT=148ND(20NE,20NE)148ND;
 RTY=INEL-SCATT;
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,5;
 INC-ENGY-LAB=116.0MEV;
 EXC-ENGY=0.752MEV;
 J-PTY=4+;
 EXC-ENGY-EMT=0.0KEV;
 J-PTY-EMT=0+;
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 THTC DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA
 (DEG) (MB/SR) (MB/SR)
 3.657E+01 3.184E+01 +-4.825E+00
 4.097E+01 2.931E+01 +-4.442E+00
 4.535E+01 2.167E+01 +-3.678E+00
 4.752E+01 3.200E+01 +-4.850E+00
 4.965E+01 2.688E+01 +-4.073E+00
 5.212E+01 2.558E+01 +-4.387E+00
 5.425E+01 1.866E+01 +-3.511E+00
 5.630E+01 2.430E+01 +-4.126E+00
 5.843E+01 1.539E+01 +-2.333E+00
 6.067E+01 1.355E+01 +-2.300E+00
 6.281E+01 1.120E+01 +-1.698E+00
 6.718E+01 5.684E+00 +-1.395E+00
 7.145E+01 4.360E+00 +-1.141E+00
 \END;
 /*===================================================================*/