DARPE: Search Results
 /*===================================================================*/
 /* NRDF D1724 Data No.5                                              */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,5;
 D#=D1724;
 TITLE=/ Core-excited states in the doubly magic 68Ni and its
         neighbor 69Cu /;
 ATH=(T.ISHII'1', M.ASAI'1', A.MAKISHIMA'2', I.HOSSAIN'3', M.OGAWA'3',
      J.HASEGAWA'3', M.MATSUDA'1', S.ICHIKAWA'1');
 INST-ATH=(2JPNJAE'1', 2JPNJPN'2', 2JPNTIT'3');
      /* '1' Advanced Science Research Center */
      /* '2' Department of Liberal Arts, National Defence Medical
              College, Tokorozawa, Saitama */
      /* '3' Research Laboratory for Nuclear Reactors */
 REF=PRL;
 VLP=84(2000)39;
 RCTS=(70ZR(198PT,X)68NI, 70ZR(198PT,X)69CU);
 PHQS=(X'4', HALF-LIFE, DATA'5');
 /* '4' Decay curve */
 /* '5' In-plane to out-of-plane ratio for the gamma-ray
    W(in)/W(out) */
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,5;
 /* 2002-09-27 : Converted, Data cannot converted to EXFOR E1724 */
 RTY=X'6';
 /* '6' Deep-inelastic scattering */
 ENR=X%;
 CHM=ELM;
 PHYS-FORM=SLD;
 THK-TGT=4.3MG/CM**2;
 BAC=X;
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=VDGT;
 INST-ACC=2JPNJAE'7';
 /* '7' JAERI tandem booster [S.Takeuchi et al.,
        Nucl.Instrum.Methods Phys.Res. A382(1996)153]. */
 INC-ENGY-LAB=566MEV;
 BEAM-INTNSTY=0.1NA;
 POL-PRJ=0%;
 ANT-COINC=NO;
 DET-SYS=(SI'8',GE'9');
 /* '8' Consisted by four Si Delta-E detectors and Si E detector to
        detect projectile-like fragments (PLF) inclined at 28deg to the
        beam axis so that the PLF's are incident on this detector
        perpendicularly */
 /* '9' To detect gamma-rays from stopped fragments, surrounded the
        periphery of the Si E detector */
 EFCN-DET=/ 30% for Ge detectors /;
 RCT=70ZR(198PT,X)68NI;
 PHQ=HALF-LIFE;
 DET-PARTCL=(68NI,GAMMA);
 COINC=(GAMMA,68NI);
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,5;
 INC-ENGY-LAB=566MEV;
 EMT-2=68NI;
 THTL-2=28DEG;
 EXC-ENGY=4208KEV;
 J-PTY=8+;
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 HALF-LIFE DELTA-HALF-LIFE FLAG'18'
 (NSEC) (NSEC) (NODIM)
 23.3 +-1.1 1.
 23 +-3 2.
 \END;
 /*===================================================================*/