DARPE: Search Results
 /*===================================================================*/
 /* NRDF D1586 Data No.52                                             */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,52;
 D#=D1586;
 TITLE=/ Single-particle states in 59Ni with 58Ni(d,p)59Ni reaction
         at 56 MeV and neutron-bound-state complex potentials /;
 PURPOSE=/ To measure the cross sections and analyzing powers /;
 ATH=(O.IWAMOTO'1', A.NOHTOMI'1', Y.UOZUMI'1', T.SAKAE'1', M.MATOBA'1',
      M.NAKANO'2', T.MAKI'2', N.KOORI'3');
 INST-ATH=(2JPNKYU'1', 2JPNKIT'2', 2JPNTKS'3');
      /* '1' Department of Nuclear Engineering */
      /* '2' School of Nursing and Technology */
      /* '3' Faculty of Integrated Arts and Sciences */
 REF=NP/A;
 VLP=576(1994)387;
 RCTS=58NI(D,P)59NI;
 PHQS=(SPEC-FCTR, ANGL-DSTRN, VCTR-ANALPW, SPEC-FCTR'4');
 /* '4' Sum of spectroscopic factor */
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,52;
 /* 2005-09-24 : Converted, Sr + On. Converted to EXFOR E1586 */
 /* 2005-11-07 : Altered, At + Kc + Sr. Re-digitized */
 /* Related references 
    - N.Matsuoka et al., NP/A, 455(1986)413.
 ENR=99.89%;
 CHM=ELM;
 PHYS-FORM=SLD;
 THK-TGT=0.473MG/CM**2;
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=CYC'5';
 /* '5' Isochronous cyclotron, AVF cyclotron */
 INST-ACC=2JPNRCN;
 INC-ENGY-LAB=56MEV;
 POL-PRJ=[50%;
 DET-PARTCL=P;
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=MAG'6';
 /* '6' Magnetic spectrograph RAIDEN [H.Ikegami, et al. Nucl.
        Instr. Meth. 175(1980)33] with the focal-plane detector system
        KYUSHYU [M.Matoba, et al. Nucl. Instr. Meth. 180(1981)419] */
 ERS-DET=45KEV;
 ANL=DWBA'7';
 /* '7' Code DWUCK [P.D.Kunz, code DWUCK, University of Colorado
        (unpublished)] */
 RCT=58NI(D,P)59NI;
 PHQ=VCTR-ANALPW;
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,52;
 INC-ENGY-LAB=56MEV;
 SYS-ERR=X%'235';
 /* '235' Uncertainty in run-to-run variations of the integrated
          beam current are on the order of a few percent. */
 EMT=P;
 EXC-ENGY=3.553MEV;
 J-PTY=5/2+;
 TRNSF-L=2'236';
 /* '236' Transferred angular momentum (L) */
 TRNSF-J=5/2'237';
 /* '237' Transferred spin (J) */
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 THTC AY DELTA-AY'238'
 (DEG) (NODIM) (NODIM)
 5.099E+00 2.346E-01 +-7.301E-02
 8.018E+00 1.319E-01 +-8.571E-02
 1.117E+01 5.139E-04 +-6.031E-02
 1.427E+01 9.774E-02 +-6.349E-02
 1.735E+01 -1.454E-02 +-7.618E-02
 2.046E+01 1.557E-01 +-8.891E-02
 2.363E+01 1.577E-01 +-8.253E-02
 2.662E+01 -5.300E-02 +-7.618E-02
 2.970E+01 -1.621E-01 +-1.016E-01
 3.396E+01 -3.256E-01 +-1.111E-01
 3.787E+01 -1.602E-02 +-1.079E-01
 4.190E+01 4.872E-01 +-1.301E-01
 \END;
 /*===================================================================*/