/*===================================================================*/ /* NRDF D1769 Data No.53 */ /*===================================================================*/ /* Bibliography */ /*===================================================================*/ \\BIB,53; D#=D1769; TITLE=/ Double-differential cross sections for the neutron production from heavy-ion reactions at energies E/A = 290-600 MeV /; PURPOSE=/ Systematic measurements of neutron-production cross sections from C, Ne, and Ar projectiles having E/A = 290-600 MeV on C, Cu, and Pb targets. /; ATH=(Y.IWATA'1', T.MURAKAMI'1', H.SATO'2', H.IWASE'2', T.NAKAMURA'2', T.KUROSAWA'2', L.HEILBRONN'3', R.M.RONNINGEN'4', K.IEKI'5', Y.TOZAWA'5', K.NIITA'6'); INST-ATH=(2JPNIRS'1', 2JPNTOH'2', 1USABRK'3', 1USAMSU'4', 2JPNRIK'5', 2JPNJPN'6'); /* '1' Department of Accelerator Physics and Engineering */ /* '2' Cyclotron and Radioisotope Center */ /* '4' National Superconducting Cyclotron Laboratory */ /* '5' Department of Physics */ /* '6' Research Organization for Information Science and Technology, Tokai, Naka, Ibaraki */ REF=PR/C; VLP=64(2001)054609; RCTS=(C(12C,N)X, CU(12C,N)X, PB(12C,N)X, C(20NE,N)X, CU(20NE,N)X, PB(20NE,N)X, C(40AR,N)X, CU(40AR,N)X, PB(40AR,N)X); PHQS=(ENGY-SPEC, ANGL-DSTRN, XSECTN, TOT-XSECTN, MLT); /*===================================================================*/ /* Experimental Conditions */ /*===================================================================*/ \\EXP,53; /* 2002-08-01 : Compiled, Am + Sr + On */ /* 2006-07-25 : Altered, On. Heading of data error corrected. Systematic uncertainties added. */ RTY=HEAVY-ION-RCT; ENR=NAT; CHM=ELM; PHYS-FORM=SLD; BAC=X; POL-TGT=0%; ALGN-TGT=0%; ACC=SYN'7'; /* '7' Heavy Ion Medical Accelerator in Chiba (HIMAC) facility INST-ACC=2JPNIRS; BEAM-INTNSTY=XMA'8'; /* '8' A few times 10e4-10e5 particles per pulse */ POL-PRJ=0%; DET-PARTCL=N; COINC=NO; ANT-COINC=NO; DET-SYS=(SCT'9',SCT'10',TOF); /* '9' NE102A plastic scintillator */ /* '10' NE213 liquid scintillator */ ERS-DET=XKEV'11'; /* '11' The energy resolutions are shown in Table I in reference. /* Experimental Method: - Time-of-flight RCT=CU(20NE,N)X; PHQ=ENGY-SPEC; THK-TGT=4470MG/CM**2; INC-ENGY-LAB=400.0MEV/A; ANL=X'169'; /* '169' Moving-source model, QMD and HIC */ /*===================================================================*/ /* Descriptive Parameters */ /*===================================================================*/ \\DATA,53; SYS-ERR=10%'12'; /* '12' Uncertainty in detection efficiency */ INC-ENGY-LAB=400.0MEV/A; SYS-ERR=2.5%'170'; /* '170' Uncertainty in target thickness */ THTL=30DEG; /*===================================================================*/ /* Data Table */ /*===================================================================*/ \DATA; ENGY-EMT-LAB DSIGMA/DOMEGA/DE DELTA-DSIGMA/DOMEGA/DE'171' (MEV) (MB/SR/MEV) (MB/SR/MEV) 5 111 +-25 6 62.3 +-21.1 7 57.7 +-18.3 8 27.7 +-19.1 9 66.9 +-13.0 10 32.3 +-13.2 15 16.4 +-3.7 25 10.2 +-3.3 35 17.5 +-3.0 45 15.7 +-3.0 55 12.5 +-3.1 65 10.8 +-3.4 75 12.7 +-3.2 85 18.9 +-3.2 95 20.3 +-2.9 105 14.3 +-3.4 125 19.8 +-2.5 145 18.1 +-2.0 165 11.3 +-2.2 185 13.6 +-1.6 205 9.12 +-1.95 235 14.0 +-1.6 265 11.8 +-1.1 295 8.77 +-0.97 325 6.31 +-0.77 365 5.14 +-0.67 405 3.23 +-0.41 465 1.58 +-0.28 525 1.15 +-0.26 605 0.462 +-0.147 725 0.212 +-0.059 885 2.89e-02 +-2.10e-02 1085 -2.31e-02 +-5.43e-02 1285 1.15e-02 +-1.25e-02 1485 4.62e-02 +-2.09e-02 1685 2.31e-02 +-1.59e-02 1885 1.15e-02 +-1.14e-02 \END; /*===================================================================*/ |