DARPE: Search Results
 /*===================================================================*/
 /* NRDF D1941 Data No.57                                             */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,57;
 D#=D1941;
 TITLE=/ The elastic and inelastic scattering of protons by magnesium
         in the energy range from 7.3 MeV to 15.9 MeV /;
 ATH=(K.MATSUDA'1', Y.NAGAHARA'1', Y.ODA'1', N.YAMAMURO'1',
      S.KOBAYASHI'1');
 INST-ATH=(2JPNINS'1');
 REF=NP;
 VLP=27(1961)1;
 /* Secondary reference 
    - INS-J, 29(1960) (N.Yamamuro et al., Numerical data)
 RCTS=(24MG(P,P)24MG, MG(P,P)MG);
 PHQS=(ANGL-DSTRN, XSECTN, EXC-FUNCT);
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,57;
 /* 2005-10-20 : Compiled, Kc + On. */
 ENR=NAT;
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=CYC;
 INST-ACC=2JPNINS;
 DELTA-INC-ENGY-LAB=100KEV'2';
 /* '2' Absolute errors in beam energy determination */
 ERS-PRJ=50KEV'3';
 /* '3' Relative errors in beam energy determination */
 POL-PRJ=0%;
 DET-PARTCL=P;
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=(SCT'4',PROP-CNTR'5');
 /* '4' To measure angluar distributions and emitted spectra */
 /* '5' To measure emitted spectrum, and to suppress gamma and
        alpha in angular distribution measurements */
 RCT=24MG(P,P)24MG;
 RTY=INEL-SCATT;
 PHQ=EXC-FUNCT;
 INC-ENGY-LAB=7.32[15.85MEV;
 /* Analysis:
    - Integration of angular distribution
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,57;
 DELTA-INC-ENGY-LAB=100KEV'6';
 /* '6' Absolute errors in beam energy determination */
 SYS-ERR=10%'7';
 /* '7' Uncertainty in absolute cross section */
 STATIST-ERR=<3%'8';
 /* '8' Maximum uncertainty in counting statistics in most cases.
        This is modified to +5%-8% at 90 deg to 165 deg due to
        insufficient discrimination in inelastic scattering */
 EXC-ENGY=1.37MEV;
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 INC-ENGY-LAB XSECTN
 (MEV) (MB)
 7.32 285
 7.63 271
 7.70 339
 7.79 336
 8.30 231
 8.79 290
 8.92 308
 9.09 284
 9.26 269
 9.39 280
 9.56 272
 9.72 274
 9.86 290
 10.03 315
 10.20 322
 10.64 252
 11.15 179
 11.62 215
 12.10 174
 12.62 138
 13.15 129
 13.59 124
 14.06 126
 14.45 168
 14.87 153
 15.33 150
 15.85 123
 \END;
 /*===================================================================*/