/*===================================================================*/ /* NRDF D0815 Data No.6 */ /*===================================================================*/ /* Bibliography */ /*===================================================================*/ \\BIB,6; D#=D815; TITLE=/Analyzing power of the neutron continuum spectrum for the 93Nb(p,nX) reaction at 65 MeV and a DWBA analysis/; PURPOSE=/To provide stringent test for various theories by simultaneous fitting of analyzing powers as well as cross sections for both neutron and proton spectra/; ATH=(H.SAKAI'1', K.HATANAKA'1', N.MATSUOKA'1', T.SAITO'1', A.SHIMIZU'1', T.MOTOBAYASHI'2', T.SHIBATA'1'); INST-ATH=(2JPNRCN'1', 2JPNOSA'2'); /* '2' Department of Physics */ REF=PL/B; VLP=133(1983)375; RCTS=93NB(P,N)X; PHQS=(ENGY-SPEC'3', ANALPW, ANGL-DSTRN); /* '3' Double differential cross section */ /*===================================================================*/ /* Experimental Conditions */ /*===================================================================*/ \\EXP,6; /* 2003-10-24 : Converted, Data converted to EXFOR E815 and EXFOR O0522 */ ENR=X%; CHM=ELM; PHYS-FORM=SLD'4'; /* '4' Metallic foil */ THK-TGT=43.6MG/CM**2; BAC=SELF; POL-TGT=0%; ALGN-TGT=0%; ACC=CYC'5'; /* '5'Isochronous cyclotron, RCNP AVF cyclotron */ INST-ACC=2JPNRCN; INC-ENGY-LAB=65MEV; BEAM-INTNSTY=50NA'6'; /* '6' maximum beam current */ POL-PRJ=82.5+-2.5%'7'; /* '7' The beam polarization was measured continuously with a 12C-polarimeter placed down stream the main scattering chamber DET-PARTCL=N; COINC=NO; ANT-COINC=NO; DET-SYS=SCT'8'; /* '8' two liquid scintillation counters (NE213) to detect neutrons */ /* Experimental Method: - Time-of-flight (To determine outgoing neutron energy. The time resolution (FWHM) of the beam burst was typically 1.0-1.5 ns, and corresponding energy resolutions of the neutrons were about 4 and 2 MeV for 50 and 30 MeV neutrons, respectively.) RCT=93NB(P,N)X; PHQ=ANALPW; /*===================================================================*/ /* Descriptive Parameters */ /*===================================================================*/ \\DATA,6; INC-ENGY-LAB=65MEV; SYS-ERR=10%'28'; /* '28' Estimated errors in the absolute magnitude of the cross section due to uncertainties in the neutron detection efficiency calculation */ EMT=N; THTL=70DEG; DELTA-ENGY-EMT-LAB=+-0.28MEV'29'; /* '29' Data-point reader uncertainty */ /*===================================================================*/ /* Data Table */ /*===================================================================*/ \DATA; ENGY-EMT-LAB ANALPW DELTA-ANALPW'30' (MEV) (NODIM) (NODIM) 15.76 0.029 +-0.004 16.73 0.037 +-0.007 18.09 0.043 +-0.006 19.89 0.032 +-0.007 21.82 0.048 +-0.006 22.95 0.066 +-0.005 24.31 0.074 +-0.006 25.05 0.091 +-0.007 27.21 0.096 +-0.006 28.39 0.094 +-0.005 29.54 0.108 +-0.006 31.26 0.126 +-0.004 31.61 0.143 +-0.005 33.06 0.117 +-0.01 33.8 0.136 +-0.007 34.63 0.117 +-0.006 36.13 0.146 +-0.011 37.18 0.2 +-0.011 38.36 0.201 +-0.009 39.54 0.199 +-0.01 40.21 0.169 +-0.019 41.58 0.171 +-0.021 42.56 0.173 +-0.016 43.68 0.197 +-0.019 44.81 0.137 +-0.019 45.22 0.21 +-0.018 46.64 0.27 +-0.021 47.47 0.177 +-0.017 49.04 0.177 +-0.018 49.85 0.248 +-0.024 50.73 0.287 +-0.024 51.74 0.279 +-0.024 53.06 0.301 +-0.02 54.04 0.301 +-0.026 \END; /*===================================================================*/ |