DARPE: Search Results
 /*===================================================================*/
 /* NRDF D0816 Data No.6                                              */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,6;
 D#=D816;
 TITLE=/ Tensor analyzing powers of the proton continuum spectra from
         deuteron breakup at 56 MeV /;
 ATH=(N.MATSUOKA'1', K.HATANAKA'1', H.SAKAI'1', T.SAITO'1', K.HOSONO'1',
      T.ITAHASHI'1', A.SHIMIZU'1', M.KONDO'1', H.SAKAGUCHI'2',
      F.OHTANI'2');
 INST-ATH=(2JPNRCN'1', 2JPNKTO'2');
      /* '2' Department of Physics */
 REF=NP/A;
 VLP=408(1983)99;
 RCTS=(58NI(D,P)X, 90ZR(D,P)X);
 PHQS=(DBL-DIFF-XSECTN, TNSR-ANALPW);
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,6;
 /* 2007-08-24 : Converted, N.Otuka. Converted to EXFOR E0816 */
 CHM=ELM;
 PHYS-FORM=SLD;
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=CYC'3';
 /* '3' Isochronous cyclotron, AVF cyclotron */
 INST-ACC=2JPNRCN;
 INC-ENGY-LAB-RANGE=56MEV;
 BEAM-INTNSTY=5[40NA;
 POL-PRJ=70[80%;
 DET-PARTCL=P;
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=(SI'4',GE'4',SI'5',NAI'5',EDE);
 /* '4' To detect protons */
 /* '5' To detect protons (6, 8, 10, 13 deg) */
 RCT=58NI(D,P)X;
 PHQ=DBL-DIFF-XSECTN;
 ENR=99.8%;
 THK-TGT=3.79MG/CM**2;
 /* Data points lower than 20 MeV and higher than 45 MeV are mostly
    omitted because of high density of data points */
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,6;
 INC-ENGY-LAB=56MEV;
 STATIST-ERR=<2.5%'16';
 /* '16' Maximum statistical uncertainty (<2.5%) */
 THTL=30DEG;
 DELTA-DSIGMA/DOMEGA/DE=10%'17';
 /* '17' Uncertainty in absolute cross section, mainly due to
         uncertainty in target thickness */
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 ENGY-EMT-LAB DSIGMA/DOMEGA/DE
 (MEV) (MB/SR/MEV)
 1.8652E+01 4.012E+00
 1.9621E+01 4.198E+00
 2.0590E+01 4.190E+00
 2.1656E+01 4.376E+00
 2.2626E+01 4.757E+00
 2.3499E+01 4.945E+00
 2.4565E+01 5.130E+00
 2.5534E+01 5.123E+00
 2.6406E+01 5.310E+00
 2.7471E+01 4.912E+00
 2.8441E+01 5.099E+00
 2.9507E+01 5.090E+00
 3.0572E+01 4.693E+00
 3.1541E+01 4.685E+00
 3.2413E+01 4.678E+00
 3.3382E+01 4.670E+00
 3.4447E+01 4.272E+00
 3.5415E+01 3.681E+00
 3.6383E+01 3.284E+00
 3.7448E+01 3.081E+00
 3.8320E+01 2.880E+00
 3.9385E+01 2.482E+00
 4.0547E+01 2.084E+00
 4.1322E+01 1.883E+00
 4.2484E+01 1.679E+00
 4.3550E+01 1.670E+00
 4.4325E+01 1.275E+00
 4.5099E+01 1.074E+00
 \END;
 /*===================================================================*/