/*===================================================================*/ /* NRDF D1243 Data No.6 */ /*===================================================================*/ /* Bibliography */ /*===================================================================*/ \\BIB,6; D#=D1243; TITLE=/ Target dependence of charge distributions in spallation reactions of medium-mass nuclei with 12 GeV protons /; ATH=(T.ASANO'1', Y.ASANO'1', Y.IGUCHI'1', H.KUDO'1', S.MORI'1', M.NOGUCHI'1', Y.TAKADA'1', H.HIRABAYASHI'2', H.IKEDA'2', K.KATOH'2', K.KONDO'2', M.TAKASAKI'2', T.TOMINAKA'2', A.YAMAMOTO'2'); INST-ATH=(2JPNTSU'1', 2JPNKEK'2'); /* '1' Institute of Applied Physics */ REF=PR/C; VLP=28(1983)1718; RCTS=(TI(P,X)X, FE(P,X)X, 59CO(P,X)X, NI(P,X)X, CU(P,X)X, ZN(P,X)X); PHQS=XSECTN; /*===================================================================*/ /* Experimental Conditions */ /*===================================================================*/ \\EXP,6; /* 2007-01-18 : Converted, N.Otuka. Converted to EXFOR E1243 */ /* Related references - H.Hirabayashi et al., JPJ, 51(1982)3098. Reference for monitor. See also NRDF D0962 DATA 1. PHQ=XSECTN; /* Additional results shown but not compiled - Charge distribution (Shown in Fig.2 in reference) - Mass distribution (Shown in Fig.3 in reference) ENR=NAT; CHM=ELM; PHYS-FORM=SLD; POL-TGT=0%; ALGN-TGT=0%; ACC=SYN; INST-ACC=2JPNKEK; INC-ENGY-LAB-RANGE=12GEV; POL-PRJ=0%; DET-PARTCL=GAMMA'3'; /* '3' Decay data not given */ COINC=NO; ANT-COINC=NO; DET-SYS=GE(LI)'4'; /* '4' For gamma-ray spectroscopy */ /* Experimental Method: - Stacked target irradiation (Total thickness of 0.5 g/cm2) - Activation (Irradiation for 10 min) - Gamma ray spectrometry (Performed during 3 months starting about a few hours after the end of irradiation) /* By authors: Detection of nuclides with lifetimes shorter than about one hour are precluded. */ RCT=59CO(P,X)X'23'; /* '23' See DATA section for atomic number (Z) and mass number (A) of products */ THK-TGT=8.36MG/CM**2; MONTR-RCT=/ 27AL(P,X)24NA /; /*===================================================================*/ /* Descriptive Parameters */ /*===================================================================*/ \\DATA,6; INC-ENGY-LAB=12GEV; TOT-ERR=X%'5'; /* '5' Uncertainty in detection efficiency of gamma rays and statistical errors for photopeak yields (Uncertainty in beam intensity calibration is not included.) */ SYS-ERR=(10%'6',15%'7'); /* '6' Uncertainty in beam intensity calibration */ /* '7' Maximum uncertainty in detection efficiency (15% below 200 keV, 5% above 400 keV) */ DATA1=8.1MB'24'; /* '24' Used for calibration of the beam intensity monitoring system */ DELTA-DATA1=0.9MB; /*===================================================================*/ /* Data Table */ /*===================================================================*/ \DATA; Z A SIGMA',25' DELTA-SIGMA'' (NODIM) (NODIM) (MB) (MB) 11. 22 1.96 +-0.16 11. 24 3.38 +-0.20 12. 28 0.47 +-0.03 18. 41 0.69 +-0.04 19. 43 0.99 +-0.07 21. 43 1.27 +-0.10 21. 47 2.35 +-0.35 23. 48 5.93 +-0.90 24. 51 15.4 +-0.8 25. 56 3.22 +-0.16 27. 56 3.27 +-0.18 27. 57 17.0 +-2.6 28. 57 0.11 +-0.01 \END; /*===================================================================*/ |