DARPE: Search Results
 /*===================================================================*/
 /* NRDF D1462 Data No.6                                              */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,6;
 D#=D1462;
 TITLE=/ Polarization transfer in the deuteron break-up reaction at
         56 MeV /;
 PURPOSE=/ To Study the break-up mechanism in deuteron induced
           reactions /;
 ATH=(H.SAKAMOTO'1', M.NAKAMURA'1', H.SAKAGUCHI'1', H.OGAWA'1',
      S.KOBAYASHI'1', S.KATO'2', N.MATSUOKA'3', K.HATANAKA'3',
      T.NORO'3');
 INST-ATH=(2JPNKTO'1', 2JPNOSA'2', 2JPNRCN'3');
      /* '1' Department of Physics */
      /* '2' Laboratory of Nuclear Studies */
 REF=PL/B;
 VLP=155(1985)227;
 RCTS=(12C(D,P)13C, 58NI(D,P)59NI, 209BI(D,P)210BI);
 PHQS=(POL-TRNSF, DBL-DIFF-XSECTN);
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,6;
 /* 2005-11-28 : Converted, N.Otuka. Converted to EXFOR E1462 */
 /* 2007-03-04 : Altered, Mh + N.Otuka. DDX data added */
 CHM=ELM;
 PHYS-FORM=SLD;
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=CYC'4';
 /* '4' Isochronous cyclotron, AVF cyclotron */
 INST-ACC=2JPNRCN;
 INC-ENGY-LAB-RANGE=56MEV;
 POL-PRJ=75[80%;
 DET-PARTCL=P;
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=(SI'5',GE'5',EDE);
 /* '5' To measure polarization */
 ANL=(PWBA,DWBA'6');
 /* '6' Code DWUCK5 */
 /* 2007-02-27 : Altered, Mh. Re-digitized */
 RCT=209BI(D,P)210BI;
 PHQ=POL-TRNSF;
 ENR=NAT;
 THK-TGT=362.9MG/CM**2;
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,6;
 INC-ENGY-LAB=56MEV;
 SYS-ERR=<3%'17';
 /* '17' Total systematic error. Uncertainty due to analyzing
         power of polarimeter, beam polarization, geometrical
         misalignment of polarimeter and ambiguity of evaluating
         effective analyzing power */
 THTL=20.0DEG;
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 ENGY-EMT-LAB DNN DELTA-DNN'18'
 (MEV) (NODIM) (NODIM)
 2.215E+01 5.028E-01 +-5.014E-02
 3.091E+01 6.883E-01 +-7.855E-02
 3.653E+01 6.131E-01 +-6.518E-02
 \END;
 /*===================================================================*/