DARPE: Search Results
 /*===================================================================*/
 /* NRDF D1894 Data No.6                                              */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,6;
 D#=D1894;
 TITLE=/ Experimental studies on the proton-induced activation
         reactions of molybdenum in the energy range 22-67 MeV /;
 PURPOSE=/ To give reliable excitation functions for Mo+p reactions
           in the energy range 22-67 MeV /;
 ATH=(M.S.UDDIN'1', M.HAGIWARA'1', F.TARKANYI'2', F.DITROI'2',
      M.BABA'1');
 INST-ATH=(2JPNTOH'1', 3HUNDEB'2');
      /* '1' Cyclotron and Radioisotope Center */
 REF=ARI;
 VLP=60(2004)911;
 /* Secondary references 
    - Takacs, Private communication(2004)
    - Hagiwara, Private communication(2004)
    - JAERI-C, 2004-005(2004)138 (M.S.Uddin et al., Proc. of the 2003
      Symposium on Nuclear Data)
 RCTS=(27AL(P,X)24NA, 27AL(P,X)22NA, CU(P,X)65ZN, CU(P,X)62ZN,
       CU(P,X)56CO, 100MO(P,X)99MO, MO(P,X)93MO, MO(P,X)96TC,
       MO(P,X)94TC, MO(P,X)95TC, MO(P,X)90NB, MO(P,X)92NB, MO(P,X)96NB,
       MO(P,X)95NB, MO(P,X)86ZR, MO(P,X)88ZR, MO(P,X)89ZR, MO(P,X)86Y,
       MO(P,X)87Y, MO(P,X)88Y);
 PHQS=XSECTN;
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,6;
 /* 2004-05-12 : Compiled, C.Kurokawa + N.Otuka */
 /* 2007-03-30 : Altered, Bk (ATOMKI) + N.Otuka. Reference added */
 PHQ=XSECTN;
 ENR=NAT;
 CHM=ELM;
 PHYS-FORM=SLD;
 THK-TGT=XMG/CM**2'3';
 /* '3' 49.58 micro-meter (Mo), 104.2 micro-meter (Cu) and 102
        micro-meter (Al) */
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=CYC'4';
 /* '4' Isochronous cyclotron, k=90 MeV AVF Cyclotron */
 INST-ACC=2JPNTOH'5';
 /* '5' Cyclotron and Radioisotope Center */
 BEAM-INTNSTY=[25NA;
 POL-PRJ=0%;
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=HPGE'6';
 /* '6' To measure activities of radioactive products of the target
        and monitors. The efficiency versus energy curve of the
        detector was determined experimentally using standard gamma-ray
        point sources with known strength, 152Eu, 133Ba, 241Am. 60Co
        and 137Cs. Efficiency is also calculated using the EGS4 Monte
        Carlo Code [Nelson et al, 1985]. */
 /* Experimental Method:
    - Stacked target irradiation (Stack was assembled from
      molybdenum, copper and aluminium as Cu-Al-Mo and 10 groups were
      set together in an aluminium holder for irradiation.)
    - Energy degradation by foils (Energy degradation along the stack
      was determined using the computer program SRIM-2002 [J.F. Ziegler
      et al., The stopping and range of ions in solids, Pergamon, New
      York, 1984.] assuming the incident energy was 70 MeV.)
 /* Analysis:
    - Decay curve analysis (Two or more radionuclides emitted
      gamma-rays having very close energies, which were difficult to
      separate by the graphical analysis of the multicomponent decay
      curve, were analyzed using the difference in half-life of the
      nuclides by plotting the photon emission rate as a function of
      time.)
 /* Gamma energies given (except 90Tc and 90Nb) are obtained by private
    communication with authors. */
 /* Related references 
    - S.Takacs et al., JRN, 257(2003)195.
    Reference with which data agree (Agree in lower energy region). See
    also EXFOR D4115.002.
    - B.Scholten et al., ARI, 51(1999)69.
    Reference with which data disagree (Disagree except data at 22 and
    35 MeV). See also EXFOR O0737.002.
    - V.N.Levkovskij, LEVKOVSKIJ, (1991).
    Reference with which data agree (Agree in lower energy region). See
    also EXFOR A0510.250.
    - M.C.Lagunas-Solar et al., ARI, 42(1991)643.
    Reference with which data disagree. See also EXFOR C0068.003.
 RCT=100MO(P,X)99MO;
 DET-PARTCL=GAMMA'18';
 /* '18' Delayed gamma from 99Mo */
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,6;
 SYS-ERR=(5.8%'7',[3%'8');
 /* '7' Uncertainty in monitor flux */
 /* '8' Uncertainty in efficiency calibration of gamma ray */
 STATIST-ERR=5%'9';
 /* '9' Maximum statistical uncertainty (0.3-5%) */
 ENGY-GAMMA=(140.0KEV'19',739.5KEV'19');
 HALF-LIFE=66HOUR'19';
 /* '19' Delayed gamma from 99Mo */
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 INC-ENGY-LAB XSECTN'20' DELTA-XSECTN'20'
 (MEV) (MB) (MB)
 22.343 18.19 +-1.37
 29.671 28.28 +-3.07
 35.8 69.67 +-7.49
 41.239 99.34 +-10.59
 46.193 95.17 +-10.15
 50.781 84.97 +-9.06
 55.055 75.56 +-8.06
 59.093 74.29 +-7.92
 62.903 76.71 +-8.18
 66.58 80.45 +-8.58
 \END;
 /*===================================================================*/