DARPE: Search Results
 /*===================================================================*/
 /* NRDF D1921 Data No.6                                              */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,6;
 D#=D1921;
 TITLE=/ Activation cross-sections of long-lived products of
         proton-induced nuclear reactions on zinc /;
 ATH=(F.TARKANYI'1', F.DITROI'1', J.CSIKAI'1,2', S.TAKACS'1',
      M.S.UDDIN'3', M.HAGIWARA'3', M.BABA'3', YU.N.SHUBIN'4',
      A.I.DITYUK'4');
 INST-ATH=(3HUNDEB'1', 3HUNKOS'2', 2JPNTOH'3', 4RUSFEI'4');
      /* '2' Institute of Experimental Physics */
      /* '3' Cyclotron and Radioisotope Center */
 REF=ARI;
 VLP=62(2005)73;
 RCTS=(ZN(P,X)66GA, ZN(P,X)67GA, ZN(P,X)62ZN, ZN(P,X)65ZN,
       ZN(P,X)69ZN, ZN(P,X)64CU, ZN(P,X)57NI, ZN(P,X)55CO, ZN(P,X)56CO,
       ZN(P,X)57CO, ZN(P,X)58CO, ZN(P,X)60CO, ZN(P,X)52MN,
       ZN(P,X)54MN);
 PHQS=XSECTN;
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,6;
 /* 2005-07-01 : Compiled, Tk + On. */
 PHQ=XSECTN;
 ENR=NAT;
 CHM=ELM;
 PHYS-FORM=SLD'5';
 /* '5' Stacked with Cu (50 micro-meter) and Al (100 micro-meter)
        monitor foils */
 THK-TGT=XMG/CM**2'6';
 /* '6' 650 micro-meter */
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=CYC;
 INST-ACC=2JPNTOH'7';
 /* '7' Cyclotron and Radioisotope Center */
 POL-PRJ=0%;
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=HPGE'8';
 /* '8' To measure activity non-destructively */
 ANL=X'9';
 /* '9' ALICE-IPPE model code (A.I.Dityuk et al., 1998) */
 /* Experimental Method:
    - Activation
    - Stacked target irradiation (Prepared by inserting Zn target
      foils, Cu and Al monitor foils together in sequence)
    - Gamma ray spectrometry
 /* Related references 
    - V.N.Levkovski, LEVKOVSKIJ, (1991).
    Reference with which data agree. See also EXFOR A0510.092.
    - V.N.Levkovski, LEVKOVSKIJ, (1991).
    Reference with which data agree. See also EXFOR A0510.096.
    - K.Hilgers et al., ARI, 59(2003)343.
    Reference with which data disagree. See also EXFOR D0069.004.
 RCT=ZN(P,X)64CU;
 DET-PARTCL=GAMMA'28';
 /* '28' Delayed gamma from 64Cu */
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,6;
 SYS-ERR=(1%'10',7%'11',5%'12');
 /* '10' Uncertainty from foil thickness */
 /* '11' Uncertainty from incident proton flux */
 /* '12' Uncertainty from calculated detector efficiency */
 STATIST-ERR=10%'13';
 /* '13' Maximum uncertainty from the count rate determination of
         the photo peak areas of gamma-lines (1-10%) */
 ENGY-GAMMA=1345.8KEV'29';
 INTNSTY-GAMMA=0.00473'29';
 HALF-LIFE=12.7HOUR'29';
 /* '29' Delayed gamma from 64Cu */
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 INC-ENGY-LAB DELTA-INC-ENGY-LAB XSECTN DELTA-XSECTN
 (MEV) (MEV) (MB) (MB)
 25.6 +-2.0 8.7 +-3.6
 33.1 +-1.7 12.4 +-5.0
 39.5 +-1.4 23.3 +-7.4
 45.1 +-1.2 24.1 +-6.9
 50.2 +-1.0 22.5 +-5.6
 54.9 +-0.8 24.6 +-5.7
 59.3 +-0.6 23.7 +-5.4
 63.4 +-0.5 26.7 +-6.2
 67.4 +-0.3 28.9 +-6.3
 \END;
 /*===================================================================*/