DARPE: Search Results
 /*===================================================================*/
 /* NRDF D1927 Data No.6                                              */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,6;
 D#=D1927;
 TITLE=/ Experimental studies on excitation functions of the
         proton-induced activation reactions on silver /;
 PURPOSE=/ To present the cross-section measurement for Ag-p reaction
           in the enegy range 11-80 MeV. /;
 ATH=(M.S.UDDIN'1', M.HAGIWARA'1', M.BABA'1', F.TARKANYI'2',
      F.DITROI'2');
 INST-ATH=(2JPNTOH'1', 3HUNDEB'2');
      /* '1' Cyclotron and Radioisotope Center */
 REF=ARI;
 VLP=62(2005)533;
 /* Secondary reference 
    - UDDIN, Private communication(2005)
 RCTS=(AG(P,X)103PD, AG(P,X)101PD, AG(P,X)100PD, AG(P,X)99RH,
       AG(P,X)100RH, AG(P,X)101RH, AG(P,X)102RH, AG(P,X)105RH,
       AG(P,X)97RU, AG(P,X)105AG, AG(P,X)106AG);
 PHQS=XSECTN;
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,6;
 /* 2005-06-29 : Compiled, Tk + On. */
 PHQ=XSECTN;
 ENR=NAT;
 CHM=ELM;
 PHYS-FORM=SLD;
 THK-TGT=XMG/CM**2'3';
 /* '3' 50 and 300 micrometer thick */
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=CYC'4';
 /* '4' Isochronous cyclotron, AVF cyclotron */
 INST-ACC=2JPNTOH'5';
 /* '5' Cyclotron and Radioisotope Center */
 POL-PRJ=0%;
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=HPGE'6';
 /* '6' To measure activities in silver target and monitors */
 /* Experimental Method:
    - Activation ( Irradiated separately with 50, 70 and 80 MeV
      proton beam)
    - Stacked target irradiation (Three stacks containing high-purity
      thin silver foils)
    - Gamma ray spectrometry (Measurement started 1 day after the end
      of bombardment)
 RCT=AG(P,X)101RH;
 DET-PARTCL=GAMMA'29';
 /* '29' Delayed gamma from 101Rh (metastable state) */
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,6;
 TOT-ERR=X%'7';
 /* '7' Uncertainty estimated from the uncertaintiies of the flux,
        counting area and detector efficiency */
 SYS-ERR=(5%'8',3%'9');
 /* '8' Upper limit of uncertainty in monitor flux (2.54-5%) */
 /* '9' Upper limit of uncertainty in efficiency calibration of
        gamma-ray (1-3%) */
 STATIST-ERR=22%'10';
 /* '10' Upper limit of statistical uncertainty (0.8-22%) */
 ENGY-GAMMA=306.86KEV'30';
 INTNSTY-GAMMA=0.935'30';
 HALF-LIFE=4.34DAY'30';
 /* '30' Delayed gamma from 101Rh (metastable state) */
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 INC-ENGY-LAB XSECTN'31' DELTA-XSECTN'31'
 (MEV) (MB) (MB)
 29.32 0.43 +-0.02
 30.26 0.34 +-0.02
 33.29 0.39 +-0.02
 36.79 1.01 +-0.06
 38.57 3.32 +-0.14
 42.70 14.02 +-0.81
 47.26 29.99 +-1.24
 48.15 34.02 +-1.97
 50.91 38.41 +-1.58
 53.12 40.00 +-2.32
 55.03 38.22 +-1.61
 58.23 33.50 +-1.41
 61.89 28.50 +-1.20
 63.35 27.25 +-1.58
 64.98 26.42 +-1.12
 68.61 30.36 +-1.76
 73.40 39.11 +-2.27
 78.12 49.54 +-2.87
 \END;
 /*===================================================================*/