DARPE: Search Results
 /*===================================================================*/
 /* NRDF D1434 Data No.65                                             */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,65;
 D#=D1434;
 TITLE=/Nuclear structure of even lead isotopes by the (p,t) reaction/;
 ATH=(M.TAKAHASHI'1', T.MURAKAMI'1', S.MORITA'1', H.ORIHARA'2',
      Y.ISHIZAKI'3', H.YAMAGUCHI'4');
 INST-ATH=(2JPNTOH'1', 2JPNTOH'2', 2JPNINS'3', 2JPNTKS'4');
      /* '1' Department of Physics */
      /* '2' Cyclotron and Radioisotope Center */
      /* '3' Institute for Nuclear Study */
      /* '4' Faculty of General Education */
 REF=PR/C;
 VLP=27(1983)1454;
 RCTS=(208PB(P,T)206PB, 206PB(P,T)204PB, 204PB(P,T)202PB);
 PHQS=ANGL-DSTRN;
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,65;
 /* 2003-10-24 : Converted, Data converted to EXFOR E1434 and EXFOR
    O0685 */
 PHQ=ANGL-DSTRN;
 ENR=>99%;
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=SYNCYC;
 INST-ACC=2JPNINS;
 INC-ENGY-LAB=51.9MEV;
 POL-PRJ=0%;
 DET-PARTCL=T;
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=(MAG'5',PROP-CNTR'6',SCT);
 /* '5' To analyze triton momentum */
 /* '6' Array of 200 proportional counters serve as position
        detectors. They form counter telescopes in combination with
        scintillation counters. */
 ERS-DET=[90KEV'7';
 /* '7' Overall energy resolution for the tritons of interest */
 ANL=DWBA'8';
 /* '8' Zero-range DWBA approximation (code DWUCK-4, [W.A.Lanford
        and J.B.McGrory, Michigan State University Cyclotron Laboratory
        Report No.MSUCL-81, 1973 (unpublished); Phys. Lett.
        45B(1973)283]) */
 RCT=206PB(P,T)204PB;
 CHM=ELM;
 PHYS-FORM=SLD'293';
 /* '293' Metallic foil */
 THK-TGT=5MG/CM**2;
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,65;
 INC-ENGY-LAB=51.9MEV;
 SYS-ERR=<20%'294';
 /* '294' Error of the absolute cross section of the ground state
          transition is estimated to be less than 20%, where the main
          part comes from the uncertainty of the solid angle of each
          counter on the focal plane of the magnetic spectrograph. */
 EMT=T;
 RSD=204PB;
 EXC-ENGY=4.85MEV;
 J-PTY=11-;
 DELTA-THTC=0.25DEG'295';
 /* '295' Data-point reader uncertainty */
 DELTA-DSIGMA/DOMEGA=1.9%'296';
 /* '296' Data-point reader uncertainty */
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 THTC DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'297'
 (DEG) (UB/SR) (%)
 6.29           19.4           +-2.1
 8.72           22.1           +-1.8
 11.22          15.63          +-1.9
 13.84          16.03          +-1.9
 16.14          11.8           +-1.9
 18.24          13.23          +-1.9
 20.88          10.92          +-1.8
 23.01          8.57           +-1.9
 25.62          10.79          +-1.9
 28.06          13.75          +-1.9
 33.12          18.2           +-1.6
 38.39          18.2           +-1.6
 40.85          17.8           +-1.7
 43.32          14.66          +-1.8
 48.08          10.38          +-1.8
 53.04          6.14           +-1.8
 58.5           4.24           +-5.
 63.6           3.68           +-5.
 69.08          2.18           +-11.
 \END;
 /*===================================================================*/