/*===================================================================*/ /* NRDF D1586 Data No.68 */ /*===================================================================*/ /* Bibliography */ /*===================================================================*/ \\BIB,68; D#=D1586; TITLE=/ Single-particle states in 59Ni with 58Ni(d,p)59Ni reaction at 56 MeV and neutron-bound-state complex potentials /; PURPOSE=/ To measure the cross sections and analyzing powers /; ATH=(O.IWAMOTO'1', A.NOHTOMI'1', Y.UOZUMI'1', T.SAKAE'1', M.MATOBA'1', M.NAKANO'2', T.MAKI'2', N.KOORI'3'); INST-ATH=(2JPNKYU'1', 2JPNKIT'2', 2JPNTKS'3'); /* '1' Department of Nuclear Engineering */ /* '2' School of Nursing and Technology */ /* '3' Faculty of Integrated Arts and Sciences */ REF=NP/A; VLP=576(1994)387; RCTS=58NI(D,P)59NI; PHQS=(SPEC-FCTR, ANGL-DSTRN, VCTR-ANALPW, SPEC-FCTR'4'); /* '4' Sum of spectroscopic factor */ /*===================================================================*/ /* Experimental Conditions */ /*===================================================================*/ \\EXP,68; /* 2005-09-24 : Converted, Sr + On. Converted to EXFOR E1586 */ /* 2005-11-07 : Altered, At + Kc + Sr. Re-digitized */ /* Related references - N.Matsuoka et al., NP/A, 455(1986)413. ENR=99.89%; CHM=ELM; PHYS-FORM=SLD; THK-TGT=0.473MG/CM**2; POL-TGT=0%; ALGN-TGT=0%; ACC=CYC'5'; /* '5' Isochronous cyclotron, AVF cyclotron */ INST-ACC=2JPNRCN; INC-ENGY-LAB=56MEV; POL-PRJ=[50%; DET-PARTCL=P; COINC=NO; ANT-COINC=NO; DET-SYS=MAG'6'; /* '6' Magnetic spectrograph RAIDEN [H.Ikegami, et al. Nucl. Instr. Meth. 175(1980)33] with the focal-plane detector system KYUSHYU [M.Matoba, et al. Nucl. Instr. Meth. 180(1981)419] */ ERS-DET=45KEV; ANL=DWBA'7'; /* '7' Code DWUCK [P.D.Kunz, code DWUCK, University of Colorado (unpublished)] */ RCT=58NI(D,P)59NI; PHQ=SPEC-FCTR'305'; /* '305' Sum of spectroscopic factor */ /*===================================================================*/ /* Descriptive Parameters */ /*===================================================================*/ \\DATA,68; INC-ENGY-LAB=56MEV; SYS-ERR=X%'306'; /* '306' Uncertainty in run-to-run variations of the integrated beam current are on the order of a few percent. */ EMT=P; /*===================================================================*/ /* Data Table */ /*===================================================================*/ \DATA; TRNSF-L TRNSF-J'307' SPEC-FCTR'308' SPEC-FCTR'309' (NODIM) (NODIM) (NODIM) (NODIM) 1 3/2 0.664 0.850 3 5/2 0.834 0.849 1 1/2 0.877 0.986 3 7/2 0.026 0.026 4 9/2 0.418 0.504 2 5/2 0.290 0.438 0 1/2 0.360 0.573 \END; /*===================================================================*/ |