/*===================================================================*/ /* NRDF D1769 Data No.69 */ /*===================================================================*/ /* Bibliography */ /*===================================================================*/ \\BIB,69; D#=D1769; TITLE=/ Double-differential cross sections for the neutron production from heavy-ion reactions at energies E/A = 290-600 MeV /; PURPOSE=/ Systematic measurements of neutron-production cross sections from C, Ne, and Ar projectiles having E/A = 290-600 MeV on C, Cu, and Pb targets. /; ATH=(Y.IWATA'1', T.MURAKAMI'1', H.SATO'2', H.IWASE'2', T.NAKAMURA'2', T.KUROSAWA'2', L.HEILBRONN'3', R.M.RONNINGEN'4', K.IEKI'5', Y.TOZAWA'5', K.NIITA'6'); INST-ATH=(2JPNIRS'1', 2JPNTOH'2', 1USABRK'3', 1USAMSU'4', 2JPNRIK'5', 2JPNJPN'6'); /* '1' Department of Accelerator Physics and Engineering */ /* '2' Cyclotron and Radioisotope Center */ /* '4' National Superconducting Cyclotron Laboratory */ /* '5' Department of Physics */ /* '6' Research Organization for Information Science and Technology, Tokai, Naka, Ibaraki */ REF=PR/C; VLP=64(2001)054609; RCTS=(C(12C,N)X, CU(12C,N)X, PB(12C,N)X, C(20NE,N)X, CU(20NE,N)X, PB(20NE,N)X, C(40AR,N)X, CU(40AR,N)X, PB(40AR,N)X); PHQS=(ENGY-SPEC, ANGL-DSTRN, XSECTN, TOT-XSECTN, MLT); /*===================================================================*/ /* Experimental Conditions */ /*===================================================================*/ \\EXP,69; /* 2002-08-01 : Compiled, Am + Sr + On */ /* 2006-07-25 : Altered, On. Heading of data error corrected. Systematic uncertainties added. */ RTY=HEAVY-ION-RCT; ENR=NAT; CHM=ELM; PHYS-FORM=SLD; BAC=X; POL-TGT=0%; ALGN-TGT=0%; ACC=SYN'7'; /* '7' Heavy Ion Medical Accelerator in Chiba (HIMAC) facility INST-ACC=2JPNIRS; BEAM-INTNSTY=XMA'8'; /* '8' A few times 10e4-10e5 particles per pulse */ POL-PRJ=0%; DET-PARTCL=N; COINC=NO; ANT-COINC=NO; DET-SYS=(SCT'9',SCT'10',TOF); /* '9' NE102A plastic scintillator */ /* '10' NE213 liquid scintillator */ ERS-DET=XKEV'11'; /* '11' The energy resolutions are shown in Table I in reference. /* Experimental Method: - Time-of-flight RCT=C(20NE,N)X; PHQ=ENGY-SPEC; THK-TGT=3600MG/CM**2; INC-ENGY-LAB=600.0MEV/A; ANL=X'217'; /* '217' Moving-source model, QMD and HIC */ /*===================================================================*/ /* Descriptive Parameters */ /*===================================================================*/ \\DATA,69; SYS-ERR=10%'12'; /* '12' Uncertainty in detection efficiency */ INC-ENGY-LAB=600.0MEV/A; SYS-ERR=6.8%'218'; /* '218' Uncertainty in target thickness */ THTL=60DEG; /*===================================================================*/ /* Data Table */ /*===================================================================*/ \DATA; ENGY-EMT-LAB DSIGMA/DOMEGA/DE DELTA-DSIGMA/DOMEGA/DE'219' (MEV) (MB/SR/MEV) (MB/SR/MEV) 5 5.66 +-2.22 6 4.99 +-1.65 7 3.66 +-1.68 8 6.32 +-1.41 9 1.33 +-1.30 10 3.33 +-1.29 15 1.46 +-0.34 25 1.23 +-0.38 35 0.599 +-0.357 45 1.53 +-0.30 55 1.40 +-0.31 65 1.70 +-0.36 75 2.16 +-0.34 85 1.53 +-0.34 95 1.26 +-0.31 105 1.46 +-0.36 125 1.75 +-0.22 145 1.13 +-0.18 165 1.22 +-0.19 185 0.599 +-0.184 205 0.583 +-0.156 235 0.444 +-0.140 265 0.433 +-0.100 295 0.399 +-0.071 325 0.233 +-0.092 365 0.208 +-0.067 405 6.66e-02 +-3.97e-02 465 4.44e-02 +-2.73e-02 525 1.11e-02 +-3.38e-02 605 0.00e+00 +-2.73e-02 725 1.39e-02 +-1.70e-02 885 8.32e-03 +-1.09e-02 1085 9.99e-03 +-9.52e-03 1285 1.17e-02 +-4.84e-03 1485 6.66e-03 +-3.52e-03 1685 1.66e-03 +-2.22e-03 1885 0.00e+00 +-1.11e-03 \END; /*===================================================================*/ |