DARPE: Search Results
 /*===================================================================*/
 /* NRDF D1231 Data No.7                                              */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,7;
 D#=D1231;
 TITLE=/ Nucleon transfer in highly mass-asymmetric reaction systems
         between 197Au and relatively light projectiles in the energy
         region below 10 MeV/u I.Target-like products /;
 ATH=(A.YOKOYAMA'1', T.SAITO'1', M.SHOJI'1', H.BABA'1', S.BABA'2',
      K.HATA'2', T.SEKINE'2', S.ICHIKAWA'2');
 INST-ATH=(2JPNOSA'1', 2JPNJAE'2');
      /* '1' Department of Chemistry and Laboratory of Nuclear Studies
 REF=ZP/A;
 VLP=332(1989)61;
 RCTS=(197AU(37CL,X)X, 197AU(37CL,X)196AU, 197AU(16O,X)X,
       197AU(14N,X)X, 197AU(14N,X)196AU, 197AU(12C,X)X);
 PHQS=XSECTN;
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,7;
 /* 2007-01-20 : Converted, N.Otuka. Converted to EXFOR E1231 */
 PHQ=XSECTN;
 /* Additional results shown but not compiled
    - Range of recoils measured (Shown in Fig.3-6 in reference)
 ENR=NAT;
 CHM=ELM;
 PHYS-FORM=SLD;
 POL-TGT=0%;
 ALGN-TGT=0%;
 POL-PRJ=0%;
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=GE(LI)'3';
 /* '3' To measure gamma rays from each foil of target stack */
 /* Experimental Method:
    - Stacked target irradiation (Several pairs of Au target foil and
      Al catcher foil)
    - Activation
    - Chemical separation (To detect small yields of Au isotopes)
 RCT=(197AU(14N,X)X/197AU(14N,X)196AU)'17';
 /* '17' See DATA section for atomic number (Z) and mass number
         (A) of products */
 ACC=CYC'18';
 /* '18' Isochronous cyclotron, AVF cyclotron */
 INST-ACC=2JPNOSA;
 INC-ENGY-LAB-RANGE=116MEV;
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,7;
 INC-ENGY-LAB=116MEV;
 TOT-ERR=X%'19';
 /* '19' Uncertainty in fitting process in decay analysis,
         gamma-ray branching ratio and statistical uncertainty */
 Z=79;
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 A ISOMER SIGMA DELTA-SIGMA HALF-LIFE
 (NODIM) (NODIM) (NODIM) (NODIM) (SEC)
 198 0 0.141 +-0.001 233020.8
 198 1 0.0048 +-0.0003 198720
 196 0 1 +-X 534211.2
 196 1 0.0241 +-0.0008 34920
 195 0 0.231 +-0.017 15811200
 194 0 0.0601 +-0.0006 142200
 193 0 0.0088 +-0.0034 63540
 192 0 0.0086 +-0.0003 18108
 \END;
 /*===================================================================*/