DARPE: Search Results
 /*===================================================================*/
 /* NRDF D2028 Data No.7                                              */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,7;
 D#=D2028;
 TITLE=/ Photonuclear spallation reactions in Cu /;
 ATH=(S.SHIBATA'1', M.IMAMURA'1', T.MIYACHI'1', M.MUTOU'1',
      K.SAKAMOTO'2', Y.HAMAJIMA'2', M.SOTO'2', Y.KUBOTA'2',
      M.YOSHIDA'2', I.FUJIWARA'2');
 INST-ATH=(2JPNINS'1', 2JPNKNZ'2', 2JPNKTO'3');
      /* '2' Department of Chemistry, Faculty of Science */
      /* '3' Institute of Atomic Energy */
 REF=PR/C;
 VLP=35(1987)254;
 RCTS=CU(GAMMA,X)X;
 PHQS=XSECTN;
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,7;
 /* 2007-03-25 : Compiled, N.Otuka */
 /* Related references 
    - B.Johnsson et al., ZP/A, 273(1975)97.
    Reference for monitor (27Al(g,2pn)24Na monitor reaction data)
    - G.Hylten, NP/A, 158(1970)225.
    Reference for monitor (12C(g,n)11C monitor reaction data)
 PHQ=XSECTN;
 ENR=NAT;
 CHM=ELM;
 PHYS-FORM=SLD;
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=(SYN'4',LINAC'5',LINAC'6');
 /* '4' 1.3 GeV electron synchrotron for E(max) >300 MeV */
 /* '5' 300 MeV electron linac for E(max) <250 MeV */
 /* '6' 500 MeV electron linac for E(max) =300 MeV */
 INST-ACC=(2JPNINS'4',2JPNTOH'5',2JPNETL'6');
 /* '5' Laboratory of Nuclear Science (LNS) */
 BEAM-INTNSTY=XMA'7';
 /* '7' 1e+8 to 1e+9 equivalent qunta per second (INS) and 1e+12 to
        1e+13 eqivalent quanta per second (LNS, ETL) */
 POL-PRJ=0%;
 ION-SOURCE=/ Bremsstrahlung (By internal target of Pt with 0.5 mm (LNS
              and ETL) or 0.05 mm (INS) thickness) /;
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=GE'8';
 /* '8' To measure gamma rays from Cu target foils and monitors */
 /* Experimental Method:
    - Activation (Irradiated for about 4 hour (INS) and 5 min (LNS,
      ETL))
 /* Authors give yield with unit of [milli-barn/equivalent quantum]. */
 RCT=CU(GAMMA,X)X'28';
 /* '28' See DATA section for atomic number (Z) and mass number
         (A) of products */
 INC-ENGY-LAB-RANGE=220MEV;
 MONTR-RCT=/ 27AL(GAMMA,N,2*P)24NA, 12C(GAMMA,N)11C /;
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,7;
 SYS-ERR=[15%'9';
 /* '9' Uncertainty in beam intensity calibration */
 INC-ENGY-LAB=220MEV;
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 Z A SIGMA'29' DELTA-SIGMA'30' HALF-LIFE
 (NODIM) (NODIM) (MB) (MB) (SEC)
 29. 64 14.8 +-1.1 1098144
 29. 61 3.10 +-0.16 12132
 29. 60 0.256 +-0.030 1380
 27. 60 0.602 +-0.043 166194.72
 27. 58 1.18 +-0.06 6117120
 25. 54 0.219 +-0.012 27000000
 \END;
 /*===================================================================*/