/*===================================================================*/ /* NRDF D1769 Data No.74 */ /*===================================================================*/ /* Bibliography */ /*===================================================================*/ \\BIB,74; D#=D1769; TITLE=/ Double-differential cross sections for the neutron production from heavy-ion reactions at energies E/A = 290-600 MeV /; PURPOSE=/ Systematic measurements of neutron-production cross sections from C, Ne, and Ar projectiles having E/A = 290-600 MeV on C, Cu, and Pb targets. /; ATH=(Y.IWATA'1', T.MURAKAMI'1', H.SATO'2', H.IWASE'2', T.NAKAMURA'2', T.KUROSAWA'2', L.HEILBRONN'3', R.M.RONNINGEN'4', K.IEKI'5', Y.TOZAWA'5', K.NIITA'6'); INST-ATH=(2JPNIRS'1', 2JPNTOH'2', 1USABRK'3', 1USAMSU'4', 2JPNRIK'5', 2JPNJPN'6'); /* '1' Department of Accelerator Physics and Engineering */ /* '2' Cyclotron and Radioisotope Center */ /* '4' National Superconducting Cyclotron Laboratory */ /* '5' Department of Physics */ /* '6' Research Organization for Information Science and Technology, Tokai, Naka, Ibaraki */ REF=PR/C; VLP=64(2001)054609; RCTS=(C(12C,N)X, CU(12C,N)X, PB(12C,N)X, C(20NE,N)X, CU(20NE,N)X, PB(20NE,N)X, C(40AR,N)X, CU(40AR,N)X, PB(40AR,N)X); PHQS=(ENGY-SPEC, ANGL-DSTRN, XSECTN, TOT-XSECTN, MLT); /*===================================================================*/ /* Experimental Conditions */ /*===================================================================*/ \\EXP,74; /* 2002-08-01 : Compiled, Am + Sr + On */ /* 2006-07-25 : Altered, On. Heading of data error corrected. Systematic uncertainties added. */ RTY=HEAVY-ION-RCT; ENR=NAT; CHM=ELM; PHYS-FORM=SLD; BAC=X; POL-TGT=0%; ALGN-TGT=0%; ACC=SYN'7'; /* '7' Heavy Ion Medical Accelerator in Chiba (HIMAC) facility INST-ACC=2JPNIRS; BEAM-INTNSTY=XMA'8'; /* '8' A few times 10e4-10e5 particles per pulse */ POL-PRJ=0%; DET-PARTCL=N; COINC=NO; ANT-COINC=NO; DET-SYS=(SCT'9',SCT'10',TOF); /* '9' NE102A plastic scintillator */ /* '10' NE213 liquid scintillator */ ERS-DET=XKEV'11'; /* '11' The energy resolutions are shown in Table I in reference. /* Experimental Method: - Time-of-flight RCT=CU(20NE,N)X; PHQ=ENGY-SPEC; THK-TGT=4470MG/CM**2; INC-ENGY-LAB=600.0MEV/A; ANL=X'232'; /* '232' Moving-source model, QMD and HIC */ /*===================================================================*/ /* Descriptive Parameters */ /*===================================================================*/ \\DATA,74; SYS-ERR=10%'12'; /* '12' Uncertainty in detection efficiency */ INC-ENGY-LAB=600.0MEV/A; SYS-ERR=2.5%'233'; /* '233' Uncertainty in target thickness */ THTL=30DEG; /*===================================================================*/ /* Data Table */ /*===================================================================*/ \DATA; ENGY-EMT-LAB DSIGMA/DOMEGA/DE DELTA-DSIGMA/DOMEGA/DE'234' (MEV) (MB/SR/MEV) (MB/SR/MEV) 5 53.1 +-33.1 6 104 +-25 7 64.6 +-22.3 8 57.7 +-19.1 9 34.6 +-19.5 10 13.8 +-13.5 30 21.3 +-2.5 70 12.0 +-2.4 110 14.1 +-2.0 150 16.6 +-2.0 190 11.7 +-1.9 230 12.2 +-1.6 270 6.35 +-1.64 310 9.23 +-1.36 350 8.19 +-1.14 390 6.17 +-1.12 430 5.48 +-0.99 490 5.23 +-0.64 550 2.15 +-0.59 630 1.93 +-0.41 750 0.904 +-0.287 910 0.173 +-0.170 1110 0.196 +-0.064 1310 8.08e-02 +-4.68e-02 1510 -2.31e-02 +-8.09e-02 1710 9.23e-02 +-4.05e-02 \END; /*===================================================================*/ |