DARPE: Search Results
 /*===================================================================*/
 /* NRDF D1769 Data No.76                                             */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,76;
 D#=D1769;
 TITLE=/ Double-differential cross sections for the neutron
         production from heavy-ion reactions at energies E/A = 290-600
         MeV /;
 PURPOSE=/ Systematic measurements of neutron-production cross
           sections from C, Ne, and Ar projectiles having E/A = 290-600
           MeV on C, Cu, and Pb targets. /;
 ATH=(Y.IWATA'1', T.MURAKAMI'1', H.SATO'2', H.IWASE'2', T.NAKAMURA'2',
      T.KUROSAWA'2', L.HEILBRONN'3', R.M.RONNINGEN'4', K.IEKI'5',
      Y.TOZAWA'5', K.NIITA'6');
 INST-ATH=(2JPNIRS'1', 2JPNTOH'2', 1USABRK'3', 1USAMSU'4', 2JPNRIK'5',
           2JPNJPN'6');
      /* '1' Department of Accelerator Physics and Engineering */
      /* '2' Cyclotron and Radioisotope Center */
      /* '4' National Superconducting Cyclotron Laboratory */
      /* '5' Department of Physics */
      /* '6' Research Organization for Information Science and
              Technology, Tokai, Naka, Ibaraki */
 REF=PR/C;
 VLP=64(2001)054609;
 RCTS=(C(12C,N)X, CU(12C,N)X, PB(12C,N)X, C(20NE,N)X, CU(20NE,N)X,
       PB(20NE,N)X, C(40AR,N)X, CU(40AR,N)X, PB(40AR,N)X);
 PHQS=(ENGY-SPEC, ANGL-DSTRN, XSECTN, TOT-XSECTN, MLT);
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,76;
 /* 2002-08-01 : Compiled, Am + Sr + On */
 /* 2006-07-25 : Altered, On. Heading of data error corrected.
    Systematic uncertainties added. */
 RTY=HEAVY-ION-RCT;
 ENR=NAT;
 CHM=ELM;
 PHYS-FORM=SLD;
 BAC=X;
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=SYN'7';
 /* '7' Heavy Ion Medical Accelerator in Chiba (HIMAC) facility
 INST-ACC=2JPNIRS;
 BEAM-INTNSTY=XMA'8';
 /* '8' A few times 10e4-10e5 particles per pulse */
 POL-PRJ=0%;
 DET-PARTCL=N;
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=(SCT'9',SCT'10',TOF);
 /* '9' NE102A plastic scintillator */
 /* '10' NE213 liquid scintillator */
 ERS-DET=XKEV'11';
 /* '11' The energy resolutions are shown in Table I in reference.
 /* Experimental Method:
    - Time-of-flight
 RCT=CU(20NE,N)X;
 PHQ=ENGY-SPEC;
 THK-TGT=4470MG/CM**2;
 INC-ENGY-LAB=600.0MEV/A;
 ANL=X'238';
 /* '238' Moving-source model, QMD and HIC */
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,76;
 SYS-ERR=10%'12';
 /* '12' Uncertainty in detection efficiency */
 INC-ENGY-LAB=600.0MEV/A;
 SYS-ERR=2.5%'239';
 /* '239' Uncertainty in target thickness */
 THTL=60DEG;
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 ENGY-EMT-LAB DSIGMA/DOMEGA/DE DELTA-DSIGMA/DOMEGA/DE'240'
 (MEV) (MB/SR/MEV) (MB/SR/MEV)
 5 61.9 +-10.4
 6 54.9 +-8.9
 7 46.4 +-7.8
 8 29.6 +-7.2
 9 35.2 +-6.5
 10 35.2 +-5.8
 20 15.3 +-1.3
 40 9.92 +-1.18
 60 8.66 +-1.30
 80 9.08 +-1.12
 100 9.22 +-0.99
 120 7.74 +-1.01
 140 7.46 +-0.98
 160 6.47 +-0.99
 180 5.49 +-0.88
 200 3.45 +-0.84
 230 4.22 +-0.55
 260 3.42 +-0.46
 290 1.50 +-0.46
 320 1.13 +-0.47
 360 1.09 +-0.31
 400 0.774 +-0.220
 460 0.586 +-0.141
 520 0.328 +-0.135
 600 0.141 +-0.071
 720 2.35e-02 +-7.81e-02
 880 3.52e-02 +-4.55e-02
 1080 2.11e-02 +-3.92e-02
 1280 4.93e-02 +-2.27e-02
 1480 2.81e-02 +-1.68e-02
 1680 2.11e-02 +-1.48e-02
 1880 7.04e-03 +-7.76e-03
 \END;
 /*===================================================================*/