DARPE: Search Results
 /*===================================================================*/
 /* NRDF D1849 Data No.8                                              */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,8;
 D#=D1849;
 TITLE=/Some evidence for neutron pick-up from the interior core
        through the (p,d) reaction/;
 ATH=(T.ISHIMATSU'1', S.HAYASHIBE'1', N.KAWAMURA'1', T.AWAYA'2',
      H.OHMURA'2', Y.NAKAJIMA'3', S.MITARAI'3');
 INST-ATH=(2JPNTOH'1', 2JPNTOK'2', 2JPNKYU'3');
      /* '1' Department of Physics */
      /* '2' Department of Physics */
      /* '3' Department of Physics */
 REF=NP/A;
 VLP=185(1972)273;
 RCTS=(100MO(P,D)99MO, 94MO(P,D)93MO, 98MO(P,D)97MO);
 PHQS=ANGL-DSTRN;
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,8;
 /* 2003-10-31 : Converted, Data converted from EXFOR O0586 */
 PHQ=ANGL-DSTRN;
 CHM=ELM;
 PHYS-FORM=SLD'4';
 /* '4' Metallic foils */
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=SYNCYC;
 INST-ACC=2JPNINS;
 INC-ENGY-LAB=52MEV;
 POL-PRJ=0%;
 DET-PARTCL=D;
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=(MAG'5',PROP-CNTR'6',PLST-SCT);
 /* '5' Broad-range magnetic spectrometer [K.Yagi et al., Nucl.
        Instr. 52(1967)29] */
 /* '6' 200 proportional counters along the focal plane followed by
        a plastic scintillation counter with 6 phototubes */
 /* Experimental Method:
    - Pulse-height discrimination (Aluminium foils placed in tront of
      proportional counters and a pulse-height discriminator for the
      outputs from the scintillation counters allowed the elimination
      of triton backgrounds from deuteron spectra.)
 RCT=94MO(P,D)93MO;
 ENR=93.9%;
 THK-TGT=2.92MG/CM**2;
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,8;
 INC-ENGY-LAB=52MEV;
 SYS-ERR=(10%'39',X%'40');
 /* '39' Uncertainty in the solid angle of spectrometer */
 /* '40' Uncertainties in the absolute cross sections are
         estimated to be less than +-20%. */
 EMT=D;
 RSD=93MO;
 EXC-ENGY=2.39MEV;
 DELTA-EXC-ENGY=0.02MEV;
 J-PTY=9/2+;
 DELTA-THTL=0.23DEG'41';
 /* '41' Data-point reader uncertainty */
 DELTA-DSIGMA/DOMEGA=1.6%'42';
 /* '42' Data-point reader uncertainty */
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 THTL DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'43'
 (DEG) (MB/SR) (%)
 5.09           2.01           +-3.
 7.67           2.17           +-1.8
 10.08          2.43           +-1.8
 12.47          2.24           +-1.8
 15.19          2.18           +-2.3
 17.42          2.13           +-1.9
 20.29          1.96           +-X
 22.65          1.554          +-X
 25.17          1.19           +-X
 28.14          0.821          +-X
 31.12          0.567          +-X
 34.15          0.54           +-2.4
 37.04          0.558          +-X
 40.07          0.544          +-X
 43.06          0.402          +-X
 46.06          0.311          +-X
 48.9           0.25           +-X
 53.21          0.23           +-X
 56.87          0.202          +-X
 \END;
 /*===================================================================*/