DARPE: Search Results
 /*===================================================================*/
 /* NRDF D1891 Data No.8                                              */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,8;
 D#=D1891;
 TITLE=/ Gamow-Teller transitions in the (7Li, 7Be) reaction at 65A MeV
 ATH=(S.NAKAYAMA'1', H.AKIMUNE'2', I.DAITO'2', H.FUJIMURA'2',
      Y.FUJITA'3', M.FUJIWARA'2', K.FUSHIMI'1', T.INOMATA'2',
      K.ISHIBASHI'2', H.KOHRI'2', N.KOORI'1', K.TAKAHISA'2', A.TAMII'4',
      M.TANAKA'5', H.TOYOKAWA'6', T.YAMAGATA'7');
 INST-ATH=(2JPNTKS'1', 2JPNRCN'2', 2JPNOSA'3', 2JPNKTO'4', 2JPNKTJ'5',
           2JPNJSR'6', 2JPNKON'7');
      /* '1' Department of Physics */
      /* '3' Department of Physics */
      /* '4' Department of Physics */
      /* '7' Department of Physics */
 REF=PR/C;
 VLP=60(1999)047303;
 RCTS=(6LI(7LI,7BE)6HE, 12C(7LI,7BE)12B, 28SI(7LI,7BE)28AL);
 PHQS=(ENGY-SPEC, ANGL-DSTRN, XSECTN-RATIO);
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,8;
 /* 2004-05-20 : Compiled, Sr + On */
 CHM=ELM;
 PHYS-FORM=SLD;
 BAC=SELF;
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=CYC;
 INST-ACC=2JPNRCN;
 INC-ENGY-LAB=65MEV/A;
 BEAM-INTNSTY=[1NA;
 CHRG-INC-ION=3+;
 POL-PRJ=0%;
 DET-SYS=(MAG'8',SCT'9');
 /* '8' Grand RAIDEN spectrograph [M. Fujiwara et al., Nucl.
        Instrum. Meth. A422(1999)484] to analyze 7Be ejectiles. The
        aperture of entrance slit of the Grand RAIDEN was set to be
        +-25 mr horizontally and +-15 mr vertically. The angular
        resolution in horizontal (theta) was about 2mr, but in vertical
        (phi) was only about 10mr. */
 /* '9' GSO gamma-detector system NYMPHS [S. Nakayama et al., Nucl.
        Instrum. Meth. A404(1998)34] to detect 7Be 0.43 MeV gamma-ray.
        The total absolute detection efficiency was about 0.2. */
 ERS-DET=[500KEV'10';
 /* '10' Mainly due to beam energy spreading */
 RCT=12C(7LI,7BE)12B;
 PHQ=XSECTN-RATIO;
 ENR=98.9%;
 THK-TGT=1.0MG/CM**2;
 DET-PARTCL=(GAMMA'23',7BE);
 /* '23' Prompt gamma from 7Be */
 COINC=NO;
 ANT-COINC=(GAMMA'24',7BE);
 /* '24' Delayed gamma from 7Be */
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,8;
 INC-ENGY-LAB=65MEV/A;
 RSD=12B;
 EXC-ENGY-EMT=0.43MEV'25';
 /* '25' Level energy for numerator of ratio */
 EXC-ENGY-EMT=0.0MEV'26';
 /* '26' Level energy for denominator of ratio */
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 THTC XSECTN-RATIO DELTA-XSECTN-RATIO
 (DEG) (NODIM) (NODIM)
 6.281E-01 8.113E-01 +-8.690E-02
 1.399E+00 8.168E-01 +-9.392E-02
 2.168E+00 7.824E-01 +-9.392E-02
 2.739E+00 7.812E-01 +-1.127E-01
 3.317E+00 7.988E-01 +-1.245E-01
 3.878E+00 7.155E-01 +-1.198E-01
 4.454E+00 8.764E-01 +-1.362E-01
 \END;
 /*===================================================================*/