DARPE: Search Results
 /*===================================================================*/
 /* NRDF D1921 Data No.8                                              */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,8;
 D#=D1921;
 TITLE=/ Activation cross-sections of long-lived products of
         proton-induced nuclear reactions on zinc /;
 ATH=(F.TARKANYI'1', F.DITROI'1', J.CSIKAI'1,2', S.TAKACS'1',
      M.S.UDDIN'3', M.HAGIWARA'3', M.BABA'3', YU.N.SHUBIN'4',
      A.I.DITYUK'4');
 INST-ATH=(3HUNDEB'1', 3HUNKOS'2', 2JPNTOH'3', 4RUSFEI'4');
      /* '2' Institute of Experimental Physics */
      /* '3' Cyclotron and Radioisotope Center */
 REF=ARI;
 VLP=62(2005)73;
 RCTS=(ZN(P,X)66GA, ZN(P,X)67GA, ZN(P,X)62ZN, ZN(P,X)65ZN,
       ZN(P,X)69ZN, ZN(P,X)64CU, ZN(P,X)57NI, ZN(P,X)55CO, ZN(P,X)56CO,
       ZN(P,X)57CO, ZN(P,X)58CO, ZN(P,X)60CO, ZN(P,X)52MN,
       ZN(P,X)54MN);
 PHQS=XSECTN;
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,8;
 /* 2005-07-01 : Compiled, Tk + On. */
 PHQ=XSECTN;
 ENR=NAT;
 CHM=ELM;
 PHYS-FORM=SLD'5';
 /* '5' Stacked with Cu (50 micro-meter) and Al (100 micro-meter)
        monitor foils */
 THK-TGT=XMG/CM**2'6';
 /* '6' 650 micro-meter */
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=CYC;
 INST-ACC=2JPNTOH'7';
 /* '7' Cyclotron and Radioisotope Center */
 POL-PRJ=0%;
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=HPGE'8';
 /* '8' To measure activity non-destructively */
 ANL=X'9';
 /* '9' ALICE-IPPE model code (A.I.Dityuk et al., 1998) */
 /* Experimental Method:
    - Activation
    - Stacked target irradiation (Prepared by inserting Zn target
      foils, Cu and Al monitor foils together in sequence)
    - Gamma ray spectrometry
 RCT=ZN(P,X)55CO;
 DET-PARTCL=GAMMA'32';
 /* '32' Delayed gamma from 55Co */
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,8;
 SYS-ERR=(1%'10',7%'11',5%'12');
 /* '10' Uncertainty from foil thickness */
 /* '11' Uncertainty from incident proton flux */
 /* '12' Uncertainty from calculated detector efficiency */
 STATIST-ERR=10%'13';
 /* '13' Maximum uncertainty from the count rate determination of
         the photo peak areas of gamma-lines (1-10%) */
 ENGY-GAMMA=(477.2KEV'33',931.2KEV'34');
 INTNSTY-GAMMA=(0.202'33',0.750'34');
 HALF-LIFE=(17.53HOUR'33',17.53HOUR'34');
 /* '33' Delayed gamma from 55Co */
 /* '34' Delayed gamma from 55Co */
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 INC-ENGY-LAB DELTA-INC-ENGY-LAB XSECTN DELTA-XSECTN
 (MEV) (MEV) (MB) (MB)
 50.2 +-1.0 0.090 +-0.038
 54.9 +-0.8 0.29 +-0.08
 59.3 +-0.6 0.48 +-0.09
 63.4 +-0.5 0.52 +-0.10
 67.4 +-0.3 0.46 +-0.08
 \END;
 /*===================================================================*/