DARPE: Search Results
 /*===================================================================*/
 /* NRDF D1769 Data No.88                                             */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,88;
 D#=D1769;
 TITLE=/ Double-differential cross sections for the neutron
         production from heavy-ion reactions at energies E/A = 290-600
         MeV /;
 PURPOSE=/ Systematic measurements of neutron-production cross
           sections from C, Ne, and Ar projectiles having E/A = 290-600
           MeV on C, Cu, and Pb targets. /;
 ATH=(Y.IWATA'1', T.MURAKAMI'1', H.SATO'2', H.IWASE'2', T.NAKAMURA'2',
      T.KUROSAWA'2', L.HEILBRONN'3', R.M.RONNINGEN'4', K.IEKI'5',
      Y.TOZAWA'5', K.NIITA'6');
 INST-ATH=(2JPNIRS'1', 2JPNTOH'2', 1USABRK'3', 1USAMSU'4', 2JPNRIK'5',
           2JPNJPN'6');
      /* '1' Department of Accelerator Physics and Engineering */
      /* '2' Cyclotron and Radioisotope Center */
      /* '4' National Superconducting Cyclotron Laboratory */
      /* '5' Department of Physics */
      /* '6' Research Organization for Information Science and
              Technology, Tokai, Naka, Ibaraki */
 REF=PR/C;
 VLP=64(2001)054609;
 RCTS=(C(12C,N)X, CU(12C,N)X, PB(12C,N)X, C(20NE,N)X, CU(20NE,N)X,
       PB(20NE,N)X, C(40AR,N)X, CU(40AR,N)X, PB(40AR,N)X);
 PHQS=(ENGY-SPEC, ANGL-DSTRN, XSECTN, TOT-XSECTN, MLT);
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,88;
 /* 2002-08-01 : Compiled, Am + Sr + On */
 /* 2006-07-25 : Altered, On. Heading of data error corrected.
    Systematic uncertainties added. */
 RTY=HEAVY-ION-RCT;
 ENR=NAT;
 CHM=ELM;
 PHYS-FORM=SLD;
 BAC=X;
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=SYN'7';
 /* '7' Heavy Ion Medical Accelerator in Chiba (HIMAC) facility
 INST-ACC=2JPNIRS;
 BEAM-INTNSTY=XMA'8';
 /* '8' A few times 10e4-10e5 particles per pulse */
 POL-PRJ=0%;
 DET-PARTCL=N;
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=(SCT'9',SCT'10',TOF);
 /* '9' NE102A plastic scintillator */
 /* '10' NE213 liquid scintillator */
 ERS-DET=XKEV'11';
 /* '11' The energy resolutions are shown in Table I in reference.
 /* Experimental Method:
    - Time-of-flight
 RCT=C(40AR,N)X;
 PHQ=ENGY-SPEC;
 THK-TGT=720MG/CM**2;
 INC-ENGY-LAB=400.0MEV/A;
 ANL=X'274';
 /* '274' Moving-source model, QMD and HIC */
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,88;
 SYS-ERR=10%'12';
 /* '12' Uncertainty in detection efficiency */
 INC-ENGY-LAB=400.0MEV/A;
 SYS-ERR=6.8%'275';
 /* '275' Uncertainty in target thickness */
 THTL=30DEG;
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 ENGY-EMT-LAB DSIGMA/DOMEGA/DE DELTA-DSIGMA/DOMEGA/DE'276'
 (MEV) (MB/SR/MEV) (MB/SR/MEV)
 5 29.0 +-16.0
 6 -1.05e+01 +-1.43e+01
 7 10.5 +-12.3
 8 0.00e+00 +-1.21e+01
 9 0.00e+00 +-1.11e+01
 10 0.00e+00 +-1.04e+01
 20 2.77 +-2.09
 40 3.56 +-1.81
 60 8.83 +-1.80
 80 11.7 +-2.0
 100 13.3 +-1.9
 120 10.8 +-1.9
 140 11.9 +-1.8
 160 9.36 +-1.59
 180 8.43 +-1.68
 200 8.57 +-1.48
 230 9.58 +-1.17
 260 6.41 +-0.91
 290 6.85 +-0.82
 320 5.27 +-0.70
 360 4.61 +-0.59
 400 3.76 +-0.41
 460 2.64 +-0.29
 520 1.32 +-0.20
 600 0.791 +-0.145
 720 0.351 +-0.105
 880 9.88e-02 +-5.75e-02
 1080 -7.91e-02 +-5.86e-02
 1280 1.32e-02 +-1.04e-02
 1480 -2.64e-02 +-3.90e-02
 1680 1.32e-02 +-2.84e-02
 1880 1.32e-02 +-2.02e-02
 \END;
 /*===================================================================*/