DARPE: Search Results
 /*===================================================================*/
 /* NRDF D1769 Data No.91                                             */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,91;
 D#=D1769;
 TITLE=/ Double-differential cross sections for the neutron
         production from heavy-ion reactions at energies E/A = 290-600
         MeV /;
 PURPOSE=/ Systematic measurements of neutron-production cross
           sections from C, Ne, and Ar projectiles having E/A = 290-600
           MeV on C, Cu, and Pb targets. /;
 ATH=(Y.IWATA'1', T.MURAKAMI'1', H.SATO'2', H.IWASE'2', T.NAKAMURA'2',
      T.KUROSAWA'2', L.HEILBRONN'3', R.M.RONNINGEN'4', K.IEKI'5',
      Y.TOZAWA'5', K.NIITA'6');
 INST-ATH=(2JPNIRS'1', 2JPNTOH'2', 1USABRK'3', 1USAMSU'4', 2JPNRIK'5',
           2JPNJPN'6');
      /* '1' Department of Accelerator Physics and Engineering */
      /* '2' Cyclotron and Radioisotope Center */
      /* '4' National Superconducting Cyclotron Laboratory */
      /* '5' Department of Physics */
      /* '6' Research Organization for Information Science and
              Technology, Tokai, Naka, Ibaraki */
 REF=PR/C;
 VLP=64(2001)054609;
 RCTS=(C(12C,N)X, CU(12C,N)X, PB(12C,N)X, C(20NE,N)X, CU(20NE,N)X,
       PB(20NE,N)X, C(40AR,N)X, CU(40AR,N)X, PB(40AR,N)X);
 PHQS=(ENGY-SPEC, ANGL-DSTRN, XSECTN, TOT-XSECTN, MLT);
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,91;
 /* 2002-08-01 : Compiled, Am + Sr + On */
 /* 2006-07-25 : Altered, On. Heading of data error corrected.
    Systematic uncertainties added. */
 RTY=HEAVY-ION-RCT;
 ENR=NAT;
 CHM=ELM;
 PHYS-FORM=SLD;
 BAC=X;
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=SYN'7';
 /* '7' Heavy Ion Medical Accelerator in Chiba (HIMAC) facility
 INST-ACC=2JPNIRS;
 BEAM-INTNSTY=XMA'8';
 /* '8' A few times 10e4-10e5 particles per pulse */
 POL-PRJ=0%;
 DET-PARTCL=N;
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=(SCT'9',SCT'10',TOF);
 /* '9' NE102A plastic scintillator */
 /* '10' NE213 liquid scintillator */
 ERS-DET=XKEV'11';
 /* '11' The energy resolutions are shown in Table I in reference.
 /* Experimental Method:
    - Time-of-flight
 RCT=C(40AR,N)X;
 PHQ=ENGY-SPEC;
 THK-TGT=720MG/CM**2;
 INC-ENGY-LAB=400.0MEV/A;
 ANL=X'283';
 /* '283' Moving-source model, QMD and HIC */
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,91;
 SYS-ERR=10%'12';
 /* '12' Uncertainty in detection efficiency */
 INC-ENGY-LAB=400.0MEV/A;
 SYS-ERR=6.8%'284';
 /* '284' Uncertainty in target thickness */
 THTL=80DEG;
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 ENGY-EMT-LAB DSIGMA/DOMEGA/DE DELTA-DSIGMA/DOMEGA/DE'285'
 (MEV) (MB/SR/MEV) (MB/SR/MEV)
 5 3.56 +-2.41
 6 4.75 +-2.07
 7 5.94 +-1.57
 8 3.56 +-1.74
 9 2.38 +-1.72
 10 2.38 +-1.38
 20 2.32 +-0.35
 40 1.72 +-0.25
 60 1.72 +-0.24
 80 1.37 +-0.22
 100 1.01 +-0.20
 120 0.416 +-0.180
 140 0.416 +-0.142
 160 0.475 +-0.121
 180 0.356 +-0.082
 200 0.178 +-0.107
 230 0.119 +-0.052
 260 0.119 +-0.043
 290 0.00e+00 +-7.06e-02
 320 -7.92e-02 +-6.82e-02
 360 0.00e+00 +-3.68e-02
 400 0.00e+00 +-3.59e-02
 460 3.96e-02 +-1.50e-02
 520 1.98e-02 +-9.26e-03
 600 1.48e-02 +-3.02e-02
 720 0.00e+00 +-1.20e-02
 880 0.00e+00 +-1.24e-02
 1080 5.94e-03 +-3.80e-03
 1280 -1.19e-02 +-7.68e-03
 1480 0.00e+00 +-7.41e-03
 1680 0.00e+00 +-7.24e-03
 1880 0.00e+00 +-1.91e-03
 \END;
 /*===================================================================*/