ENTRY 32877 20251201 SUBENT 32877001 20251201 BIB 15 41 32877001 2 TITLE Measurement of 209Bi neutron inelastic scattering 32877001 3 sross section with prompt gamma-ray method 32877001 4 AUTHOR (Sun Qi, Wang Zhaohui, Zhang Qiwei, Huang Hanxiong, 32877001 5 Ren Jie, Ruan Xichao, Liu Shilong, Bao Jie, 32877001 6 Luan Guangyuan, Ding Yanyan, Chen Xiongjun, 32877001 7 Nie Yangbo, Liu Chao, Zhao Qi, Wang Jincheng, 32877001 8 He Guozhu, Du Shubin) 32877001 9 INSTITUTE (3CPRAEP) 32877001 10 REFERENCE (J,CST,56,816,2022) 32877001 11 #doi:10.7538/yzk.2022.youxian.0189 32877001 12 FACILITY (VDGT,3CPRAEP) HI-13 tandem accelerator 32877001 13 INC-SOURCE (D-D) Neutrons were produced using a D2 gas target 32877001 14 bombarded with deuterons at 6.5, 8.0 and 9.5 MeV. The 32877001 15 current was 300 nA, the pulse repetition frequency 32877001 16 was about 3 MHz. 32877001 17 SAMPLE 209Bi metal sample was 50 mm in diameter, 4 mm in 32877001 18 thickness, and 9.8 g/cm3 in density. Natural Ti 32877001 19 sample was 50 in diameter, 1 mm in thickness, and 32877001 20 4.54 g/cm3 in density. 32877001 21 METHOD (FPGAM,TOF) Time-of-flight method was used to 32877001 22 determine neutron energy. 32877001 23 DETECTOR (SCIN) A BC501A liquid scintillator detector was used 32877001 24 to monitor the neutron flux. 32877001 25 (HPGE) 4 Clover detector was used to measure produced 32877001 26 gamma-ray. Every detector was made of 4 high-purity 32877001 27 germanium crystals. The Clover detector was 32877001 28 calibrated with 152Eu, 60Co, 22Na and 133Ba standard 32877001 29 gamma-ray radioactive sources. 32877001 30 MONITOR (22-TI-48(N,INL)22-TI-48,PAR,SIG) 32877001 31 MONIT-REF (,A.D.Carlson,J,NDS,148,143,2018) 32877001 32 DECAY-MON (22-TI-48,,DG,983.5) 32877001 33 ERR-ANALYS (ERR-T) Total uncertainty 32877001 34 (ERR-S) Relative errors of the source neutron counts 32877001 35 and the full-energy peak counts 32877001 36 (ERR-1,,3.) Detector efficiency 32877001 37 (ERR-2,,1.) Sample composition 32877001 38 (ERR-3,,1.) Dimension of the sample 32877001 39 (ERR-4,,1.) Correction factor 32877001 40 (ERR-5,,1.) Location of the detector 32877001 41 STATUS (TABLE,,Sun Qi+,J,CST,56,816,2022) Text in p.822 32877001 42 HISTORY (20251201C) Compiled by Xi Tao (CNDC) 32877001 43 ENDBIB 41 0 32877001 44 NOCOMMON 0 0 32877001 45 ENDSUBENT 44 0 3287700199999 SUBENT 32877002 20251201 BIB 2 2 32877002 2 REACTION (83-BI-209(N,INL)83-BI-209,,SIG) 32877002 3 STATUS (DEP,32877003) 32877002 4 ENDBIB 2 0 32877002 5 NOCOMMON 0 0 32877002 6 DATA 4 3 32877002 7 EN DATA ERR-T ERR-S 32877002 8 MEV MB MB PER-CENT 32877002 9 9.0 1638.1 83.6 3.6 32877002 10 10.5 675.5 37.9 4.2 32877002 11 12.0 482.5 28.5 4.6 32877002 12 ENDDATA 5 0 32877002 13 ENDSUBENT 12 0 3287700299999 SUBENT 32877003 20251201 BIB 2 2 32877003 2 REACTION (83-BI-209(N,INL)83-BI-209,PAR,SIG,G) 32877003 3 DECAY-DATA (83-BI-209,,DG,1608.53,1.00) 32877003 4 ENDBIB 2 0 32877003 5 COMMON 1 3 32877003 6 E-LVL 32877003 7 KEV 32877003 8 1608.58 32877003 9 ENDCOMMON 3 0 32877003 10 DATA 4 3 32877003 11 EN DATA ERR-T ERR-S 32877003 12 MEV MB MB PER-CENT 32877003 13 9.0 666.1 34.0 3.6 32877003 14 10.5 277.0 15.6 4.2 32877003 15 12.0 188.6 11.2 4.6 32877003 16 ENDDATA 5 0 32877003 17 ENDSUBENT 16 0 3287700399999 ENDENTRY 3 0 3287799999999