ENTRY 10257 20011130 00001025700000001 SUBENT 10257001 20011130 00001025700100001 BIB 14 24 1025700100002 INSTITUTE (1USABAT) 1025700100003 REFERENCE (J,JNM,42,91,1972) 1025700100004 AUTHOR (A.A.Bauer,M.Kangilaski) 1025700100005 TITLE Helium generation in stainless steel and nickel 1025700100006 FACILITY (SPECM) 1025700100007 INC-SOURCE (REAC) ETR reactor 1025700100008 SAMPLE High purity nickel samples. 1025700100009 METHOD (MASSP) 1025700100010 Samples are irradiated in thermal reactor for a period 1025700100011 of 10 years. 1025700100012 DETECTOR (MAGSP) 1025700100013 MONITOR ((MONIT1)27-CO-59(N,G)27-CO-60,,SIG,,MXW) For thermal 1025700100014 fluence. 1025700100015 ((MONIT2)27-CO-58(N,G)27-CO-59,,SIG,,FIS) For fast 1025700100016 fluence. 1025700100017 DECAY-MON (27-CO-60-G,5.27YR) 1025700100018 ERR-ANALYS (DATA-ERR) Estimated absolute uncertainty, determined 1025700100019 from the cumulative uncertainties of sample weight, 1025700100020 isotope ratio measurement, and spike size. 1025700100021 STATUS (APRVD) Approved by author. 1025700100022 HISTORY (19720926C) 1025700100023 (19821118U) Converted to REACTION formalism. 1025700100024 (20011130A) Converted to new date formats, lower case. 1025700100025 Data error added to DATA. 1025700100026 ENDBIB 24 0 1025700100027 NOCOMMON 0 0 1025700100028 ENDSUBENT 27 0 1025700199999 SUBENT 10257002 20011130 00001025700200001 BIB 2 2 1025700200002 REACTION (28-NI-59(N,A)26-FE-56,,SIG,,SPA) 1025700200003 INC-SPECT Reactor spectrum 1025700200004 ENDBIB 2 0 1025700200005 NOCOMMON 0 0 1025700200006 DATA 5 1 1025700200007 EN-DUMMY DATA DATA-ERR MONIT1 MONIT2 1025700200008 EV B PER-CENT B B 1025700200009 0.0253 7.38 3. 37. 1650. 1025700200010 ENDDATA 3 0 1025700200011 ENDSUBENT 10 0 1025700299999 ENDENTRY 2 0 1025799999999