ENTRY 10848 19800722 00001084800000001 SUBENT 10848001 19800722 00001084800100001 BIB 12 46 1084800100002 INSTITUTE (1USAORL) 1084800100003 REFERENCE (R,ORNL-TM-6805,7909) 1084800100004 AUTHOR (R.R.SPENCER,R.GWIN,R.INGLE,H.WEAVER) 1084800100005 TITLE INTERIM REPORT ON THE ORNL ABSOLUTE MEASUREMENTS OF 1084800100006 AVERAGE PROMPT NU-BAR FOR CF-252 1084800100007 FACILITY (LINAC) OAK RIDGE ELECTRON LINEAR ACCELERATOR 1084800100008 DETECTOR (SCIN) 900-LITER NE-224 ALUMINUM SCINTILLATION TANK 1084800100009 WITH GADOLINIUM. SURROUNDED WITH THICK MARBLE WALL TO 1084800100010 REDUCE BACKGROUND FROM K-40. HORIZONTAL THROUGH-TUBE 1084800100011 OF 13.69-CM INNER DIAMETER ALUMINUM USED AS BEAM PATH.1084800100012 PROTON RECOIL NE-213 LIQUID SCINTILLATOR PLACED IN 1084800100013 NEUTRON BEAM AND NORMAL TO IT. 4.45-CM IN DIAMETER AND1084800100014 0.6-CM THICK WITH PULSE SHAPE DISCRIMINATION. 1084800100015 (FISCH) CF FISSION CHAMBER LOCATED ABOVE BEAM. CONSISTS1084800100016 OF A 0.0004 MICRO-GRAM, 0.5-CM DIAMETER CIRCLE OF CF 1084800100017 ON NICKEL FOIL OVERCOATED WITH GOLD. CHAMBER FILLED TO1084800100018 1-ATM WITH METHANE. 1084800100019 MONITOR (1-H-1(N,EL)1-H-1,,SIG) PROTON RECOIL DATA USED TO 1084800100020 NORMALIZE A MONTE CARLO CALCULATION FOR TOTAL 1084800100021 SCINTILLATOR TANK EFFICIENCY. 1084800100022 SCINTILLATOR TANK PULSE HEIGHT RESPONSE CHECKED USING 1084800100023 CF-252 FISSION GAMMAS,NEUTRON ABSORPTION GAMMA 1084800100024 RAYS AND GAMMA RAY SOURCES. 1084800100025 METHOD (TOF) TIME OF FLIGHT. FISSION EVENTS SIGNALED BY 1084800100026 COINCIDENCE BETWEEN FISSION CHAMBER AND PROMPT 1084800100027 SCINTILLATOR TANK PULSES FROM FISSION GAMMAS. NEUTRONS1084800100028 SCATTERED FROM BEAM SIGNALED BY PROTON RECOIL PULSE. 1084800100029 GRAPHITE USED TO FILL IN SCINTILLATOR THROUGH-TUBE TO 1084800100030 MINIMIZE EFFECTS OF ASYMMETRY. DETECTOR EFFICIENCY 1084800100031 FROM 0.5 TO 7.125 MEV DETERMINED USING NEUTRON WHITE 1084800100032 SOURCE. 1084800100033 CORRECTION CORRECTIONS MADE FOR- 1084800100034 -BACKGROUND 1084800100035 -SYSTEM DEAD TIME 1084800100036 -AVERAGE SCINTILLATOR TANK EFFICIENCY 1084800100037 -PULSE PILE-UP 1084800100038 -ABSORPTION BY PROTON RECOIL PHOTOMULTIPLIERS 1084800100039 -OFF- AXIS POSITION OF CF-252 SOURCE 1084800100040 -DELAYED GAMMAS 1084800100041 -FISSION CHAMBER DISCRIMINATION LEVEL 1084800100042 -FISSION LOSS DUE TO TANK COINCIDENCE 1084800100043 -MONTE CARLO UNCERTAINTY 1084800100044 -FALSE FISSION EVENTS 1084800100045 ERR-ANALYS ERRORS CONTRIBUTED BY UNCERTAINTIES IN CORRECTIONS 1084800100046 STATUS (APRVD) APPROVED BY R.R.SPENCER, 80/7/18. 1084800100047 HISTORY (800312C) 1084800100048 ENDBIB 46 0 1084800100049 NOCOMMON 0 0 1084800100050 ENDSUBENT 49 0 1084800199999 SUBENT 10848002 19811120 00001084800200001 BIB 2 2 1084800200002 REACTION (98-CF-252(0,F),PR,NU) 1084800200003 HISTORY (811120A) REACTION CORRECTED. 1084800200004 ENDBIB 2 0 1084800200005 NOCOMMON 0 0 1084800200006 DATA 2 1 1084800200007 DATA DATA-ERR 1084800200008 NO-DIM NO-DIM 1084800200009 3.783 0.010 1084800200010 ENDDATA 3 0 1084800200011 ENDSUBENT 10 0 1084800299999 ENDENTRY 2 0 1084899999999