ENTRY 11536 19860502 00001153600000001 SUBENT 11536001 19860502 00001153600100001 BIB 11 18 1153600100002 INSTITUTE (1USAWVU) 1153600100003 REFERENCE (T,CLATOR,69) 1153600100004 (J,DA/B,30,2850,6912) 1153600100005 TITLE NEUTRON INDUCED REACTIONS BETWEEN 14.4 AND 16.7 MEV. 1153600100006 AUTHOR (I.G.CLATOR) 1153600100007 FACILITY (VDG) 1153600100008 INC-SOURCE (D-T) 1153600100009 DETECTOR (GELI) 1153600100010 (NAICR) 1153600100011 METHOD (ACTIV). MIXED POWDERS. 1153600100012 ERR-ANALYS UNCERTAINTY GIVEN INCLUDES 1153600100013 - CALIBRATION OF DETECTOR (1 PERCENT) 1153600100014 - POSITIONING OF SAMPLE AROUND TARGET (5 PERCENT) 1153600100015 - ENERGY SPREAD IN NEUTRON FLUX (5 PERCENT) 1153600100016 STATUS (SCSRS) 1153600100017 HISTORY (760715T) TRANSLATED FROM SCISRS 1153600100018 (830412A) CONVERTED TO REACTION FORMALISM 1153600100019 (860502A) BIB UPDATE, MONITOR ADDED TO DATA. 1153600100020 ENDBIB 18 0 1153600100021 NOCOMMON 0 0 1153600100022 ENDSUBENT 21 0 1153600199999 SUBENT 11536002 19860502 00001153600200001 BIB 4 4 1153600200002 REACTION (12-MG-24(N,P)11-NA-24,,SIG) 1153600200003 DECAY-DATA (11-NA-24-G,15.0HR,DG,1369.,1.0) 1153600200004 MONITOR (26-FE-56(N,P)25-MN-56,,SIG) 1153600200005 DECAY-MON (25-MN-56,2.58HR,DG,847.,0.99) 1153600200006 ENDBIB 4 0 1153600200007 NOCOMMON 0 0 1153600200008 DATA 5 3 1153600200009 EN DATA DATA-ERR MONIT MONIT-ERR 1153600200010 MEV B B MB MB 1153600200011 1.44 +01 1.99 -01 3.2 -02 100. 6. 1153600200012 1.57 +01 1.76 -01 2.8 -02 86. 5. 1153600200013 1.67 +01 1.50 -01 2.4 -02 70. 4. 1153600200014 ENDDATA 5 0 1153600200015 ENDSUBENT 14 0 1153600299999 SUBENT 11536003 19860502 00001153600300001 BIB 4 4 1153600300002 REACTION (24-CR-52(N,P)23-V-52,,SIG) 1153600300003 DECAY-DATA (23-V-52,3.76MIN,DG,1434.,1.0) 1153600300004 MONITOR (13-AL-27(N,P)12-MG-27,,SIG) 1153600300005 DECAY-MON (12-MG-27,9.45MIN,DG,840.,0.70) 1153600300006 ENDBIB 4 0 1153600300007 NOCOMMON 0 0 1153600300008 DATA 5 3 1153600300009 EN DATA DATA-ERR MONIT MONIT-ERR 1153600300010 MEV B B MB MB 1153600300011 1.44 +01 1.15 -01 2.5 -02 68. 8. 1153600300012 1.57 +01 9.9 -02 2.2 -02 56. 7. 1153600300013 1.67 +01 8.9 -02 2.0 -02 48. 6. 1153600300014 ENDDATA 5 0 1153600300015 ENDSUBENT 14 0 1153600399999 SUBENT 11536004 19860502 00001153600400001 BIB 4 4 1153600400002 REACTION (29-CU-65(N,P)28-NI-65,,SIG) 1153600400003 DECAY-DATA (28-NI-65,2.55HR,DG,1483.,0.25) 1153600400004 MONITOR (26-FE-56(N,P)25-MN-56,,SIG) 1153600400005 DECAY-MON (25-MN-56,2.58HR,DG,847.,0.99) 1153600400006 ENDBIB 4 0 1153600400007 NOCOMMON 0 0 1153600400008 DATA 5 3 1153600400009 EN DATA DATA-ERR MONIT MONIT-ERR 1153600400010 MEV B B MB MB 1153600400011 1.44 +01 2.35 -02 5.2 -03 100. 6. 1153600400012 1.57 +01 2.03 -02 4.5 -03 86. 5. 1153600400013 1.67 +01 1.80 -02 4.0 -03 70. 4. 1153600400014 ENDDATA 5 0 1153600400015 ENDSUBENT 14 0 1153600499999 SUBENT 11536005 19870116 00001153600500001 BIB 5 5 1153600500002 REACTION (29-CU-65(N,A)27-CO-62-M,,SIG) 1153600500003 DECAY-DATA (27-CO-62-M,13.75MIN,DG,1740.,0.19) 1153600500004 MONITOR (13-AL-27(N,P)12-MG-27,,SIG) 1153600500005 DECAY-MON (12-MG-27,9.45MIN,DG,840.,0.70) 1153600500006 HISTORY (870116A) REACTION PRODUCT, DECAY-DATA CORRECTED. 1153600500007 ENDBIB 5 0 1153600500008 NOCOMMON 0 0 1153600500009 DATA 5 3 1153600500010 EN DATA DATA-ERR MONIT MONIT-ERR 1153600500011 MEV B B MB MB 1153600500012 1.44 +01 1.97 -02 3.2 -03 68. 8. 1153600500013 1.57 +01 1.77 -02 2.8 -03 56. 7. 1153600500014 1.67 +01 1.49 -02 2.4 -03 48. 6. 1153600500015 ENDDATA 5 0 1153600500016 ENDSUBENT 15 0 1153600599999 SUBENT 11536006 19860502 00001153600600001 BIB 4 4 1153600600002 REACTION (29-CU-65(N,2N)29-CU-64,,SIG) 1153600600003 DECAY-DATA (29-CU-64,12.8HR,DG,1340.,0.005) 1153600600004 MONITOR (26-FE-56(N,P)25-MN-56,,SIG) 1153600600005 DECAY-MON (25-MN-56,2.58HR,DG,847.,0.99) 1153600600006 ENDBIB 4 0 1153600600007 NOCOMMON 0 0 1153600600008 DATA 5 3 1153600600009 EN DATA DATA-ERR MONIT MONIT-ERR 1153600600010 MEV B B MB MB 1153600600011 1.44 +01 9.39 -01 1.50 -01 100. 6. 1153600600012 1.57 +01 9.51 -01 1.50 -01 86. 5. 1153600600013 1.67 +01 9.50 -01 1.50 -01 70. 4. 1153600600014 ENDDATA 5 0 1153600600015 ENDSUBENT 14 0 1153600699999 SUBENT 11536007 19860502 00001153600700001 BIB 4 4 1153600700002 REACTION (30-ZN-68(N,P)29-CU-68-G,(M),SIG) 1153600700003 DECAY-DATA (29-CU-68-G,31.SEC,DG,1078.,0.95) 1153600700004 MONITOR (13-AL-27(N,P)12-MG-27,,SIG) 1153600700005 DECAY-MON (12-MG-27,9.45MIN,DG,1013.,0.30) 1153600700006 ENDBIB 4 0 1153600700007 NOCOMMON 0 0 1153600700008 DATA 5 3 1153600700009 EN DATA DATA-ERR MONIT MONIT-ERR 1153600700010 MEV B B MB MB 1153600700011 1.44 +01 8.9 -03 2.0 -03 68. 8. 1153600700012 1.57 +01 6.9 -03 2.8 -03 56. 7. 1153600700013 1.67 +01 1.49 -02 2.4 -03 48. 6. 1153600700014 ENDDATA 5 0 1153600700015 ENDSUBENT 14 0 1153600799999 SUBENT 11536008 19860502 00001153600800001 BIB 5 5 1153600800002 REACTION (30-ZN-66(N,P)29-CU-66,,SIG) 1153600800003 DECAY-DATA (29-CU-66,5.2MIN,DG,1039.,0.09) 1153600800004 MONITOR (13-AL-27(N,P)12-MG-27,,SIG) 1153600800005 DECAY-MON (12-MG-27,9.45MIN,DG,1013.,0.30) 1153600800006 HISTORY (860502C) 1153600800007 ENDBIB 5 0 1153600800008 NOCOMMON 0 0 1153600800009 DATA 5 3 1153600800010 EN DATA DATA-ERR MONIT MONIT-ERR 1153600800011 MEV MB MB MB MB 1153600800012 1.44 +01 72. 16. 68. 8. 1153600800013 1.57 +01 60. 13. 56. 7. 1153600800014 1.67 +01 54. 12. 48. 6. 1153600800015 ENDDATA 5 0 1153600800016 ENDSUBENT 15 0 1153600899999 ENDENTRY 8 0 1153699999999