ENTRY 12947 20140414 14011294700000001 SUBENT 12947001 20140414 14011294700100001 BIB 11 21 1294700100002 INSTITUTE (1USAORL) 1294700100003 REFERENCE ((J,RE,93,249,1986)=(C,85SANTA,1,585,1985)) 1294700100004 AUTHOR (L.W.Weston,J.H.Todd) 1294700100005 TITLE Capture in the 1.15-keV iron resonance 1294700100006 FACILITY (LINAC,1USAORL) ORELA 1294700100007 DETECTOR (STANK) C6F6 liquid scintillators 10 cm in diam. and 1294700100008 4-cm thick, were used as the gamma-ray detectors. 1294700100009 (IOCH) A 10B overlap filter was used and NaF and 1294700100010 S filters were permanently in the beam. The relative 1294700100011 flux was measured with a parallel plate 10B pulse 1294700100012 ionization chamberl2 placed 26 cm in front of the 1294700100013 iron sample. This chamber covered the complete neutron 1294700100014 beam and contained 56 mu-g/cm2 of 10B. 1294700100015 SAMPLE Natural iron, 5.08 by 6.35 by 0.051 cm. 1294700100016 MONITOR (5-B-10(N,A)3-LI-7,,SIG) 1294700100017 ERR-ANALYS (DATA-ERR) No information available 1294700100018 STATUS (APRVD) L.W.Weston, 1985/11/25. 1294700100019 HISTORY (19851029C) 1294700100020 (20140414A) SD: Updated to new date formats,lower case.1294700100021 Corrections according last EXFOR rules and Dict. 1294700100022 Ref. 85SANTA,JA20 corrected. 1294700100023 ENDBIB 21 0 1294700100024 NOCOMMON 0 0 1294700100025 ENDSUBENT 24 0 1294700199999 SUBENT 12947002 20140414 14011294700200001 BIB 1 2 1294700200002 REACTION ((26-FE-56(N,G),,ARE)//(26-FE-56(N,G),,ARE)) 1294700200003 Relative to 1.15 keV resonance. 1294700200004 ENDBIB 2 0 1294700200005 NOCOMMON 0 0 1294700200006 DATA 4 1 1294700200007 EN-RES-DN EN-RES-NM DATA DATA-ERR 1294700200008 KEV KEV NO-DIM NO-DIM 1294700200009 1.15 22.8 2.91 0.17 1294700200010 ENDDATA 3 0 1294700200011 ENDSUBENT 10 0 1294700299999 ENDENTRY 2 0 1294799999999