ENTRY 14380 20160315 14161438000000001 SUBENT 14380001 20160315 14161438000100001 BIB 9 36 1438000100002 TITLE Large beta-delayed one and two neutron emission rates 1438000100003 in the decay of 86Ga 1438000100004 AUTHOR (K.Miernik,K.P.Rykaczewski,C.J.Gross,R.Grzywacz, 1438000100005 M.Madurga,D.Miller,J.C.Batchelder,I.N.Borzov, 1438000100006 N.T.Brewer,C.Jost,A.Korgul,C.Mazzocchi,A.J.Mendez II, 1438000100007 Y.Liu,S.V.Paulauskas,D.W.Stracener,J.A.Winger, 1438000100008 M.Wolinska-Cichocka,E.F.Zganjar) 1438000100009 INSTITUTE (1USAORL,3POLWWA,1USATEN,1USAOAU,4ZZZDUB,1USAVBT, 1438000100010 1USAMSS,1USALSU) 1438000100011 REFERENCE (J,PRL,111,132502,2013) 1438000100012 FACILITY (VDGT,1USAORL) Experiment was performed at the 1438000100013 Holifield Radioactive Ion Beam Facility at Oak Ridge 1438000100014 National Laboratory using Low-Energy Radioactive Ion 1438000100015 Beam Spectroscopy Station (LeRIBSS). 1438000100016 SAMPLE (31-GA-86,ENR=1.0) Ions of 86Ga were extracted from 1438000100017 the Resonant Ionization Laser Ion Source (RILIS), 1438000100018 utilizing a two-step ionization scheme, accelerated 1438000100019 to 200 keV kinetic energy, and mass analyzed by a 1438000100020 two-stage mass separator having mass resolving powers 1438000100021 M/dM of 1000 and 10 000, respectively.The beam was 1438000100022 implanted into the moving tape collector. Tape 1438000100023 collector periodically transported implanted ions to 1438000100024 the detector setup center. 1438000100025 DETECTOR (SCIN) Beta rays were detected by two plastic beta 1438000100026 ray detectors 1438000100027 (HPGE)Gamma rays were detected using two high-purity 1438000100028 germanium clover detectors 1438000100029 (HE3SP) Neutrons were detected using 48 3He 1438000100030 ionization chambers. The neutron counters, containing 1438000100031 in total about 600 liters of 3He, were mounted in a 1438000100032 thermalizing high-density polyethylene (HDPE) support 1438000100033 with a 1-mm-thick cadmium outer shielding. 1438000100034 ERR-ANALYS (DATA-ERR) No information on source of uncertainties 1438000100035 HISTORY (20140120C) Compiled by S.H. 1438000100036 (20160315A) OS. DECAY-DATA corrected and moved to 1438000100037 sub.2; sub.3 added 1438000100038 ENDBIB 36 0 1438000100039 NOCOMMON 0 0 1438000100040 ENDSUBENT 39 0 1438000199999 SUBENT 14380002 20160315 14161438000200001 BIB 4 6 1438000200002 REACTION (31-GA-86(0,B-)32-GE-86,NUM,PN) 1438000200003 DECAY-DATA (31-GA-86,43.0MSEC) Uncertainty (+21,-15)ms 1438000200004 Measured by author 1438000200005 STATUS (TABLE) Data taken from tab. 1 of 1438000200006 Phys.Rev.Lett.111,132502,2013 1438000200007 HISTORY (20160315A) DECAY-DATA corrected 1438000200008 ENDBIB 6 0 1438000200009 NOCOMMON 0 0 1438000200010 DATA 3 2 1438000200011 PART-OUT DATA DATA-ERR 1438000200012 NO-DIM NO-DIM NO-DIM 1438000200013 1. 0.60 0.10 1438000200014 2. 0.20 0.10 1438000200015 ENDDATA 4 0 1438000200016 ENDSUBENT 15 0 1438000299999 SUBENT 14380003 20160315 14161438000300001 BIB 3 4 1438000300002 REACTION (32-GE-86(0,B-)33-AS-86,NUM,PN) 1438000300003 STATUS (TABLE) Data from text on p.4 of 1438000300004 Phys.Rev.Lett.111,132502,2013 1438000300005 HISTORY (20160315C) 1438000300006 ENDBIB 4 0 1438000300007 NOCOMMON 0 0 1438000300008 DATA 3 1 1438000300009 PART-OUT DATA DATA-ERR 1438000300010 NO-DIM NO-DIM NO-DIM 1438000300011 1. 0.45 0.15 1438000300012 ENDDATA 3 0 1438000300013 ENDSUBENT 12 0 1438000399999 ENDENTRY 3 0 1438099999999