ENTRY 14385 20140404 14021438500000001 SUBENT 14385001 20140404 14021438500100001 BIB 14 34 1438500100002 TITLE Neutron-capture cross-section measurements of 136Xe 1438500100003 between 0.4 and 14.8 MeV 1438500100004 AUTHOR (M.Bhike, W.Tornow) 1438500100005 INSTITUTE (1USADKE,1USATNL) 1438500100006 REFERENCE (J,PR/C,89,031602,2014) 1438500100007 #doi:10.1103/PhysRevC.89.031602 1438500100008 FACILITY (VDGT,1USATNL) 1438500100009 INC-SOURCE (P-T)Neutrons of energy between 0.4 and 3.5 MeV 1438500100010 generated with proton beams incident on tritiated 1438500100011 target assembly 1438500100012 (D-D)Neutrons of energy between 4.1 and 7.31 MeV 1438500100013 generated with deuteron beams incident on deuterium gas1438500100014 cell 1438500100015 (D-T)Neutrons of energy 14.79 MeV generated with 1438500100016 deuteron beam incident on tritiated target assembly 1438500100017 SAMPLE (54-XE-136,ENR=0.999)A titanium sphere with inner 1438500100018 diameter of 0.96 cm and wall thickness of 0.2 mm 1438500100019 contained xenon gas of mass of 725 mg and pressurized 1438500100020 to 250 atm enclosed with a Cd foil of thickness 0.5 mm 1438500100021 DETECTOR (HPGE) 1438500100022 (SCIN)BC-501A neutron monitor detector 1438500100023 METHOD (ACTIV)Irradiation for 15 min and counting for 12 min 1438500100024 ANALYSIS (DECAY)The intensity of 455.49 keV gamma-ray line was 1438500100025 measured in about two minute intervals over a time 1438500100026 period of more than three half- lives and half-life was1438500100027 confirmed. 1438500100028 PART-DET (DG) 1438500100029 ERR-ANALYS (ERR-T) Total uncertainty 1438500100030 (ERR-1,,,U) Uncertainty on counting statistics for Xe 1438500100031 (ERR-2,,,U) Uncertainty on counting statistics from 1438500100032 monitor samples 1438500100033 (MONIT-ERR) Uncertainty in the monitor cross section 1438500100034 STATUS (TABLE)Table II of Phys.Rev. C 89, 031602 (2014) 1438500100035 HISTORY (20140404C)compiled by Megha Bhike 1438500100036 ENDBIB 34 0 1438500100037 NOCOMMON 0 0 1438500100038 ENDSUBENT 37 0 1438500199999 SUBENT 14385002 20140404 14021438500200001 BIB 6 11 1438500200002 REACTION (54-XE-136(N,G)54-XE-137,,SIG) 1438500200003 DECAY-DATA (54-XE-137,3.818MIN,DG,455.490,0.31) 1438500200004 MONITOR (79-AU-197(N,G)79-AU-198,,SIG) Two high-purity gold 1438500200005 foils of same diameter as that of Xe sphere and 1438500200006 thickness of 0.0025 mm were attached to the front and 1438500200007 back side of the sphere for incident neutron fluence 1438500200008 determination. 1438500200009 DECAY-MON (79-AU-198-G,2.6947D,DG,411.80205,0.9562) 1438500200010 MONIT-REF (41183002,A.N.Davletshin+,J,YK,1993,(1),13,1993) 1438500200011 STATUS (COREL,14385003) Data at 0.85 MeV