ENTRY 14398 20141029 14041439800000001 SUBENT 14398001 20141029 14041439800100001 BIB 14 35 1439800100002 TITLE Measurements of the 40Ar(n,g)41Ar radiative-capture 1439800100003 cross section between 0.4 and 14.8 MeV 1439800100004 AUTHOR (M.Bhike,B.Fallin,W.Tornow) 1439800100005 INSTITUTE (1USADKE,1USATNL) 1439800100006 REFERENCE (J,PL/B,736,361,2014) 1439800100007 #doi:10.1016/j.physletb.2014.07.044 1439800100008 FACILITY (VDGT,1USATNL) 1439800100009 INC-SOURCE (P-T)Neutrons of energy between 0.4 and 3.4 MeV 1439800100010 generated with proton beams incident on tritiated 1439800100011 titanium target assembly 1439800100012 (D-D)Neutrons of energy between 4.1 and 7.0 MeV 1439800100013 generated with deuteron beams incident on deuterium gas1439800100014 cell 1439800100015 (D-T)Neutrons of energy 14.8 MeV generated with 1439800100016 deuteron beam incident on tritiated titanium target 1439800100017 assembly 1439800100018 DETECTOR (HPGE) 1439800100019 (SCIN)BC-501A neutron monitor detector 1439800100020 METHOD (ACTIV) Irradiation for 2 hours and counting of Ar cell1439800100021 was performed for 12 hours 1439800100022 SAMPLE A stainless steel sphere with inner diameter of 20 mm 1439800100023 and wall thickness of 0.5 mm contained argon gas of 1439800100024 mass of 1.585g and pressurized to 210 atm enclosed with1439800100025 a Cd foil of thickness 0.5 mm. 1439800100026 ANALYSIS (DECAY)The intensity of 1293.64 keV gamma-ray line was 1439800100027 measured over a time period of more than three 1439800100028 half-lives and half-life was confirmed. 1439800100029 PART-DET (DG) 1439800100030 ERR-ANALYS (ERR-T) Total uncertainty 1439800100031 (MONIT-ERR) Uncertainty in reference cross section 1439800100032 (ERR-1,,,U) Uncertainty on counting statistics for Ar 1439800100033 (ERR-2,,,U) Uncertainty on counting statistics from 1439800100034 monitor samples 1439800100035 STATUS (TABLE) Table 2 of Phy. Lett. B 736, 361 (2014) 1439800100036 HISTORY (20141029C)compiled by Megha Bhike 1439800100037 ENDBIB 35 0 1439800100038 NOCOMMON 0 0 1439800100039 ENDSUBENT 38 0 1439800199999 SUBENT 14398002 20141029 14041439800200001 BIB 5 12 1439800200002 REACTION (18-AR-40(N,G)18-AR-41,,SIG) 1439800200003 DECAY-DATA (18-AR-41,109.61MIN,DG,1293.64,0.9916) 1439800200004 MONITOR (49-IN-115(N,G)49-IN-116-M1,,SIG)Two high-purity indium1439800200005 foils of same diameter as that of Ar sphere and 1439800200006 thickness of 0.125 mm were attached to the front and 1439800200007 back side of the sphere for incident neutron fluence 1439800200008 determination. 1439800200009 DECAY-MON (49-IN-116-M1,54.29MIN,DG,1293.56,0.848) 1439800200010 STATUS (COREL,14398003) Data set normalized by 1439800200011 115In(n,n')115mIn monitor reaction 1439800200012 (COREL,14398004) Data set normalized by 1439800200013 197Au(n,2n)196Au monitor reaction 1439800200014 ENDBIB 12 0 1439800200015 NOCOMMON 0 0 1439800200016 DATA 8 1 1439800200017 EN EN-RSL DATA ERR-T ERR-1 MONIT 1439800200018 MONIT-ERR ERR-2 1439800200019 MEV MEV MB MB PER-CENT MB 1439800200020 MB PER-CENT 1439800200021 0.37 0.10 1.19 0.06 1.07 180.0 1439800200022 5.40 0.67 1439800200023 ENDDATA 6 0 1439800200024 ENDSUBENT 23 0 1439800299999 SUBENT 14398003 20140404 14041439800300001 BIB 6 13 1439800300002 REACTION (18-AR-40(N,G)18-AR-41,,SIG) 1439800300003 DECAY-DATA (18-AR-41,109.61MIN,DG,1293.64,0.9916) 1439800300004 MONITOR (49-IN-115(N,INL)49-IN-115-M,,SIG) Two high-purity 1439800300005 indium foils of same diameter as that of Ar sphere and 1439800300006 thickness of 0.125 mm were attached to the front and 1439800300007 back side of the sphere for incident neutron fluence 1439800300008 determination. 1439800300009 DECAY-MON (49-IN-115-M,4.486HR,DG,336.241,0.458) 1439800300010 STATUS (COREL,14398002)Data set normalized by 1439800300011 115In(n,g)116mIn monitor reaction 1439800300012 (COREL,14398004)Data set normalized by 1439800300013 197Au(n,2n)196Au monitor reaction 1439800300014 COMMENT 335.241 keV in Table 1 should be read as 336.241 keV 1439800300015 ENDBIB 13 0 1439800300016 NOCOMMON 0 0 1439800300017 DATA 8 8 1439800300018 EN EN-RSL DATA ERR-T ERR-1 MONIT 1439800300019 MONIT-ERR ERR-2 1439800300020 MEV MEV MB MB PER-CENT MB 1439800300021 MB PER-CENT 1439800300022 1.31 0.10 1.03 0.07 1.12 132.20 1439800300023 3.17 0.36 1439800300024 1.84 0.13 0.75 0.05 0.81 236.74 1439800300025 5.68 0.16 1439800300026 2.72 0.16 0.64 0.10 10.25 344.65 1439800300027 8.09 10.03 1439800300028 3.41 0.16 0.57 0.10 10.18 335.76 1439800300029 7.89 10.01 1439800300030 4.09 0.63 0.48 0.03 1.49 318.48 1439800300031 7.48 0.16 1439800300032 5.46 0.47 0.37 0.05 1.29 337.95 1439800300033 8.79 10.1 1439800300034 6.00 0.41 0.36 0.06 10.13 348.59 1439800300035 9.06 10.03 1439800300036 7.04 0.34 0.31 0.05 11.05 328.51 1439800300037 11.66 10.01 1439800300038 ENDDATA 20 0 1439800300039 ENDSUBENT 38 0 1439800399999 SUBENT 14398004 20141029 14041439800400001 BIB 5 12 1439800400002 REACTION (18-AR-40(N,G)18-AR-41,,SIG) 1439800400003 DECAY-DATA (18-AR-41,109.61MIN,DG,1293.64,0.9916) 1439800400004 MONITOR (79-AU-197(N,2N)79-AU-196,,SIG) Two high-purity 1439800400005 gold foils of same diameter as that of Ar sphere and 1439800400006 thickness of 0.1 mm were attached to the front and 1439800400007 back side of the sphere for incident neutron fluence 1439800400008 determination. 1439800400009 DECAY-MON (79-AU-196-G,6.1699D,DG,355.73,0.87) 1439800400010 STATUS (COREL,14398002)Data set normalized by 1439800400011 115In(n,g)116m1In monitor reaction 1439800400012 (COREL,14398003)Data set normalized by 1439800400013 197Au(n,2n)196Au monitor reaction 1439800400014 ENDBIB 12 0 1439800400015 NOCOMMON 0 0 1439800400016 DATA 8 1 1439800400017 EN EN-RSL DATA ERR-T ERR-1 MONIT 1439800400018 MONIT-ERR ERR-2 1439800400019 MEV MEV MB MB PER-CENT MB 1439800400020 MB PER-CENT 1439800400021 14.80 0.07 0.45 0.02 1.35 2164.20 1439800400022 23.37 0.13 1439800400023 ENDDATA 6 0 1439800400024 ENDSUBENT 23 0 1439800499999 ENDENTRY 4 0 1439899999999