ENTRY 14494 20171211 14381449400000001 SUBENT 14494001 20171211 14381449400100001 BIB 10 30 1449400100002 TITLE A high precision n-p scattering measurement at 14.9 MeV1449400100003 AUTHOR (N.V.Kornilov,S.M.Grimes,T.N.Massey,C.E.Brient, 1449400100004 D.E.Carter,J.E.O'Donnell,K.W.Cooper,A.D.Carlson, 1449400100005 F.B.Bateman,C.R.Heimbach,R.C.Haight,N.Boukharouba) 1449400100006 INSTITUTE (1USAOHO,1USANIS,1USALAS) 1449400100007 (3ALGALG)University of Guelma, Guelma 1449400100008 REFERENCE (J,EPJ/CS,146,11053,2017) 1449400100009 FACILITY (CCW,1USAOHO) The experiment was performed at the 1449400100010 Ohio University Accelerator Laboratory using a beam 1449400100011 swinger - the Swinger Spectrometer 1449400100012 SAMPLE EJ-200 scintillator with diameter of 1.5cm and 1449400100013 height of 4.5 cm was used as active sample, placed 1449400100014 20 cm from the neutron source. 1449400100015 DETECTOR (SCIN) EJ-200 scintillator with diameter of 1.5cm and 1449400100016 height of 4.5 cm was used as active sample - a 1449400100017 scatter detector. Detector was used as time of flight 1449400100018 stop detector with threshold of a constant fraction 1449400100019 discriminator fixed at 60 keV electron energy. The 1449400100020 swinger magnet was rotated around scatter detector 1449400100021 to provide different scattering angles. 1449400100022 (SCIN) Three liquid-scintillation neutron detectors 1449400100023 (NE213, D = 12.7 cm, H = 5.08 cm, PMT RCA 4522) were 1449400100024 placed at a flight path of 4.108m from the 1449400100025 scatter-detector. 1449400100026 METHOD (TOF,PSD) Neutron energy was determined by time of 1449400100027 flight 1449400100028 INC-SOURCE (D-T) Neutrons of 14.9MeV were generated with a 1449400100029 0.53MeV deuteron beam on a tritiated titanium target 1449400100030 though the T(d,n)4He reaction. 1449400100031 HISTORY (20171211C) Compiled by S.H. 1449400100032 ENDBIB 30 0 1449400100033 NOCOMMON 0 0 1449400100034 ENDSUBENT 33 0 1449400199999 SUBENT 14494002 20171211 14381449400200001 BIB 4 7 1449400200002 REACTION (1-H-1(N,EL)1-H-1,,DA) 1449400200003 STATUS (TABLE) Data taken from tab. 1 of the reference 1449400200004 MISC-COL (MISC1) Scattering angle in laboratory system 1449400200005 (MISC2) Energy of scattered neutron 1449400200006 ERR-ANALYS (ERR-S) Statistical uncertainty 1449400200007 (ERR-SYS) Systematic uncertainty 1449400200008 (ERR-T) Total uncertainty 1449400200009 ENDBIB 7 0 1449400200010 COMMON 1 3 1449400200011 EN 1449400200012 MEV 1449400200013 14.9 1449400200014 ENDCOMMON 3 0 1449400200015 DATA 7 9 1449400200016 COS-CM MISC1 MISC2 DATA-CM ERR-S ERR-SYS 1449400200017 ERR-T 1449400200018 NO-DIM ADEG MEV MB/SR PER-CENT PER-CENT 1449400200019 PER-CENT 1449400200020 0.766 20. 13.16 49.18 2.2 4.1449400200021 4.5 1449400200022 0.643 25. 12.24 49.25 2.4 3.1449400200023 3.8 1449400200024 0.5 30. 11.18 50.7 2.1 2.51449400200025 3.2 1449400200026 0.342 35. 10.00 50.48 1.7 2.51449400200027 3. 1449400200028 0.174 40. 8.74 51.75 2.8 2.11449400200029 3.5 1449400200030 0. 45. 7.45 52.13 0.4 1.81449400200031 1.8 1449400200032 -0.174 50. 6.16 51.97 2. 1.51449400200033 2.5 1449400200034 -0.342 55. 4.90 52.88 1.5 1.41449400200035 2.1 1449400200036 -0.643 65. 2.66 51.89 2. 1.21449400200037 2.3 1449400200038 ENDDATA 22 0 1449400200039 ENDSUBENT 38 0 1449400299999 ENDENTRY 2 0 1449499999999