ENTRY 14502 20180509 14411450200000001 SUBENT 14502001 20180509 14411450200100001 BIB 11 47 1450200100002 TITLE Neutron radiative capture cross section of 63,65Cu 1450200100003 between 0.4 and 7.5 MeV 1450200100004 AUTHOR (I.Newsome,M.Bhike,Krishichayan,W.Tornow) 1450200100005 INSTITUTE (1USADKE,1USATNL) 1450200100006 REFERENCE (J,PR/C,97,044617,2018) 1450200100007 FACILITY (VDGT,1USATNL) Experiment perfomed at the TUNL tandem 1450200100008 Van de Graaff accelerator facility. 1450200100009 SAMPLE Natural copper targets with diameter of 18.9-mm and 1450200100010 thickness between 1.0 and 2.5 mm. Disks were 1450200100011 supported by a thin plastic foil and mounted at 0deg 1450200100012 relative to the incident charged-particle beam at a 1450200100013 distance of 2.5 cm from the end of the deuterium gas 1450200100014 cell. To measure the neutron fluence, indium monitor 1450200100015 foils of the same cross-sectional area and 0.125-mm 1450200100016 thickness were attached to the front and back faces of 1450200100017 the copper disk. The copper target and associated 1450200100018 monitor foils were surrounded by a thin-walled cage 1450200100019 made of cadmium (0.25-mm wall thickness) to eliminate 1450200100020 the effect of thermal neutrons on the cross-section 1450200100021 results. 1450200100022 DETECTOR (HPGE) Well-shielded and well-characterized high- 1450200100023 purity germanium (HPGe) detectors was used to 1450200100024 determine the induced activities. The copper and 1450200100025 indium foil were positioned at a distance of 5 cm 1450200100026 from the front face of 60% and 30% relative 1450200100027 efficiency, respectively, HPGe detectors. 1450200100028 METHOD (ACTIV) Activation method was used. Irradiation times 1450200100029 of 15 min were used for the 65Cu and 45 min for 63Cu 1450200100030 INC-SOURCE (P-T) The 3H(p,n) 3He reaction was used at six 1450200100031 energies in the neutron energy range between 0.4 and 1450200100032 4 MeV 1450200100033 (D-D)The 2H(d,n) 3He reaction was employed at four 1450200100034 energies between 4 and 7.5 MeV. 1450200100035 ERR-ANALYS (ERR-1,2.2,3.4) Systematic uncertainty in reference 1450200100036 cross section 1450200100037 (ERR-2,3.,5.) Syst. uncertainty in monitor detection 1450200100038 efficiency 1450200100039 (ERR-3,,1.) Syst. uncertainty in monitor foil 1450200100040 geometry and gamma ray selfabsorption 1450200100041 (ERR-4) Syst. uncertainty in monitor gamma ray 1450200100042 intensity 1450200100043 (ERR-5,,1.) Syst. uncertainty in monitor neutron 1450200100044 flux correction 1450200100045 (ERR-6,,10.) Syst. uncertainty in monitor off-energy 1450200100046 neutron correction factor 1450200100047 (ERR-T) Total uncertainty 1450200100048 HISTORY (20180509C) Compiled by S.H. 1450200100049 ENDBIB 47 0 1450200100050 COMMON 1 3 1450200100051 ERR-4 1450200100052 PER-CENT 1450200100053 1.4 1450200100054 ENDCOMMON 3 0 1450200100055 ENDSUBENT 54 0 1450200199999 SUBENT 14502002 20180509 14411450200200001 BIB 6 20 1450200200002 REACTION (29-CU-63(N,G)29-CU-64,,SIG) 1450200200003 STATUS (TABLE) Data taken from tab. 2 of the reference 1450200200004 (COREL,14502003) 1450200200005 DECAY-DATA (29-CU-64,12.701HR,DG,511.,0.352) 1450200200006 MONITOR (49-IN-115(N,G)49-IN-116-M1,,SIG) 1450200200007 DECAY-MON (49-IN-116-M1,54.29MIN,DG,1293.56,0.848) 1450200200008 ERR-ANALYS (ERR-S,0.806,2.126) Statistical uncertainty 1450200200009 consisting of statistical uncertainty in 1450200200010 - monitor counts (0.1-1.4)% 1450200200011 - sample counts (0.8- 1.6)% 1450200200012 (ERR-7) Syst. uncertainty in sample detection 1450200200013 efficiency 1450200200014 (ERR-8,,1.4) Syst. uncertainty in sample foil 1450200200015 geometry and gamma ray selfabsorption 1450200200016 (ERR-9) Syst. uncertainty in sample gamma ray 1450200200017 intensity 1450200200018 (ERR-10,,1.) Syst. uncertainty in sample neutron 1450200200019 flux fluctuation correction 1450200200020 (ERR-11,,13.) Syst. uncertainty in sample off-energy 1450200200021 neutron correction factor 1450200200022 ENDBIB 20 0 1450200200023 COMMON 2 3 1450200200024 ERR-7 ERR-9 1450200200025 PER-CENT PER-CENT 1450200200026 3. 1.1 1450200200027 ENDCOMMON 3 0 1450200200028 DATA 6 2 1450200200029 EN EN-RSL DATA ERR-T MONIT MONIT-ERR 1450200200030 MEV MEV MB MB MB MB 1450200200031 0.39 0.1 25.08 1.28 176.86 3.91450200200032 0.88 0.09 13.44 0.83 150.04 5.651450200200033 ENDDATA 4 0 1450200200034 ENDSUBENT 33 0 1450200299999 SUBENT 14502003 20180509 14411450200300001 BIB 6 20 1450200300002 REACTION (29-CU-63(N,G)29-CU-64,,SIG) 1450200300003 STATUS (TABLE) Data taken from tab. 2 of the reference 1450200300004 (COREL,14502002) 1450200300005 DECAY-DATA (29-CU-64,12.701HR,DG,511.,0.352) 1450200300006 MONITOR (49-IN-115(N,INL)49-IN-115-M,,SIG) 1450200300007 DECAY-MON (49-IN-115-M,4.486HR,DG,336.24,0.459) 1450200300008 ERR-ANALYS (ERR-S,0.806,2.126) Statistical uncertainty 1450200300009 consisting of statistical uncertainty in 1450200300010 - monitor counts (0.1-1.4)% 1450200300011 - sample counts (0.8-1.6)% 1450200300012 (ERR-7) Syst. uncertainty in sample detection 1450200300013 efficiency 1450200300014 (ERR-8,,1.4) Syst. uncertainty in sample foil 1450200300015 geometry and gamma ray selfabsorption 1450200300016 (ERR-9) Syst. uncertainty in sample gamma ray 1450200300017 intensity 1450200300018 (ERR-10,,1.) Syst. uncertainty in sample neutron 1450200300019 flux fluctuation correction 1450200300020 (ERR-11,,13.) Syst. uncertainty in sample off-energy 1450200300021 neutron correction factor 1450200300022 ENDBIB 20 0 1450200300023 COMMON 2 3 1450200300024 ERR-7 ERR-9 1450200300025 PER-CENT PER-CENT 1450200300026 3. 1.1 1450200300027 ENDCOMMON 3 0 1450200300028 DATA 6 8 1450200300029 EN EN-RSL DATA ERR-T MONIT MONIT-ERR 1450200300030 MEV MEV MB MB MB MB 1450200300031 1.34 0.08 11.44 0.78 137.4 3.251450200300032 1.89 0.07 7.09 0.48 246.19 5.921450200300033 2.79 0.07 5.39 0.78 343.07 8.251450200300034 3.52 0.07 3.49 0.37 334.2 7.561450200300035 4.3 0.49 3.12 0.21 315.41 7.591450200300036 5.13 0.41 2.67 0.18 332.25 8.621450200300037 6.4 0.27 1.85 0.2 344.05 12.731450200300038 7.39 0.22 1.99 0.21 319.34 10.881450200300039 ENDDATA 10 0 1450200300040 ENDSUBENT 39 0 1450200399999 SUBENT 14502004 20180509 14411450200400001 BIB 6 20 1450200400002 REACTION (29-CU-65(N,G)29-CU-66,,SIG) 1450200400003 STATUS (TABLE) Data taken from tab. 2 of the reference 1450200400004 (COREL,14502005) 1450200400005 DECAY-DATA (29-CU-66,5.120MIN,DG,1039.2,0.0923) 1450200400006 MONITOR (49-IN-115(N,G)49-IN-116-M1,,SIG) 1450200400007 DECAY-MON (49-IN-116-M1,54.29MIN,DG,1293.56,0.848) 1450200400008 ERR-ANALYS (ERR-S,2.501,3.862) Statistical uncertainty 1450200400009 consisting of statistical uncertainty in 1450200400010 - monitor counts (0.1-1.4)% 1450200400011 - sample counts (2.5-3.6)% 1450200400012 (ERR-12) Syst. uncertainty in sample detection 1450200400013 efficiency 1450200400014 (ERR-13,,1.7) Syst. uncertainty in sample foil 1450200400015 geometry and gamma ray selfabsorption 1450200400016 (ERR-14) Syst. uncertainty in sample gamma ray 1450200400017 intensity 1450200400018 (ERR-15,,1.) Syst. uncertainty in sample neutron 1450200400019 flux fluctuation correction 1450200400020 (ERR-16,,18.) Syst. uncertainty in sample off-energy 1450200400021 neutron correction factor 1450200400022 ENDBIB 20 0 1450200400023 COMMON 2 3 1450200400024 ERR-12 ERR-14 1450200400025 PER-CENT PER-CENT 1450200400026 4. 1.1 1450200400027 ENDCOMMON 3 0 1450200400028 DATA 6 2 1450200400029 EN EN-RSL DATA ERR-T MONIT MONIT-ERR 1450200400030 MEV MEV MB MB MB MB 1450200400031 0.39 0.1 12.53 1.3 176.86 3.91450200400032 0.88 0.09 9.03 1.12 150.04 5.651450200400033 ENDDATA 4 0 1450200400034 ENDSUBENT 33 0 1450200499999 SUBENT 14502005 20180509 14411450200500001 BIB 6 20 1450200500002 REACTION (29-CU-65(N,G)29-CU-66,,SIG) 1450200500003 STATUS (TABLE) Data taken from tab. 2 of the reference 1450200500004 (COREL,14502004) 1450200500005 DECAY-DATA (29-CU-66,5.120MIN,DG,1039.2,0.0923) 1450200500006 MONITOR (49-IN-115(N,INL)49-IN-115-M,,SIG) 1450200500007 DECAY-MON (49-IN-115-M,4.486HR,DG,336.24,0.459) 1450200500008 ERR-ANALYS (ERR-S,2.501,3.862) Statistical uncertainty 1450200500009 consisting of statistical uncertainty in 1450200500010 - monitor counts (0.1-1.4)% 1450200500011 - sample counts (2.5-3.6)% 1450200500012 (ERR-12) Syst. uncertainty in sample detection 1450200500013 efficiency 1450200500014 (ERR-13,,1.7) Syst. uncertainty in sample foil 1450200500015 geometry and gamma ray selfabsorption 1450200500016 (ERR-14) Syst. uncertainty in sample gamma ray 1450200500017 intensity 1450200500018 (ERR-15,,1.) Syst. uncertainty in sample neutron 1450200500019 flux fluctuation correction 1450200500020 (ERR-16,,18.) Syst. uncertainty in sample off-energy 1450200500021 neutron correction factor 1450200500022 ENDBIB 20 0 1450200500023 COMMON 2 3 1450200500024 ERR-12 ERR-14 1450200500025 PER-CENT PER-CENT 1450200500026 4. 1.1 1450200500027 ENDCOMMON 3 0 1450200500028 DATA 6 8 1450200500029 EN EN-RSL DATA ERR-T MONIT MONIT-ERR 1450200500030 MEV MEV MB MB MB MB 1450200500031 1.34 0.08 9.65 1.1 137.4 3.251450200500032 1.89 0.07 8.59 0.97 246.19 5.921450200500033 2.79 0.07 6.6 1.1 343.07 8.251450200500034 3.52 0.07 5.03 0.89 334.2 7.561450200500035 4.3 0.49 3.44 0.25 315.41 7.591450200500036 5.13 0.41 2.55 0.29 332.25 8.621450200500037 6.4 0.27 1.67 0.67 344.05 12.731450200500038 7.39 0.22 1.82 0.7 319.34 10.881450200500039 ENDDATA 10 0 1450200500040 ENDSUBENT 39 0 1450200599999 ENDENTRY 5 0 1450299999999