ENTRY 20229 20230130 2022900000001 SUBENT 20229001 20230130 20231011 2022900100001 BIB 14 23 2022900100002 TITLE Test of the uranium-235 fission spectrum 2022900100003 representations by means of activation detectors - 2022900100004 INSTITUTE (2BLGMOL) 2022900100005 REFERENCE (J,NUK,10,280,1967) 2022900100006 (J,JNE/AB,16,447,1962) similar experiment. 2022900100007 AUTHOR (A.Fabry) 2022900100008 FACILITY (REAC,2BLGMOL) BR1-reactor, thermal column. 2022900100009 INC-SOURCE Enriched uranium fission plate. 2022900100010 INC-SPECT Fission spectrum from fission plate. 2022900100011 METHOD (ACTIV) 2022900100012 MONITOR (92-U-0(N,F),,SIG) 2022900100013 macroscopic cross-section of the fission 2022900100014 plate = 23.0 +- 0.1 1/cm. 2022900100015 Fission neutron flux calculated using 2022900100016 equation (3) of Nukleonik,10(1967)280. 2022900100017 MONIT-REF (,C.H.Westcott+,J,REA,3,(2),3,1965) 2022900100018 COMMENT Present study consistent with the results by 2022900100019 R.B.Leachman et al., J. Nucl. Energy 1,4,38(1957). 2022900100020 ERR-ANALYS (DATA-ERR) No information about source of uncertainty 2022900100021 STATUS (TABLE) Table on p.281 of Nukleonik,10(1967)280. 2022900100022 HISTORY (19721005C) 2022900100023 (20230130A) SD:Updated to new date formats,lower case. 2022900100024 Corrections in all Subents. 2022900100025 ENDBIB 23 0 2022900100026 COMMON 1 3 2022900100027 EN-DUMMY 2022900100028 MEV 2022900100029 1.0 2022900100030 ENDCOMMON 3 0 2022900100031 ENDSUBENT 30 0 2022900199999 SUBENT 20229002 20230130 20231011 2022900200001 BIB 5 7 2022900200002 REACTION (13-AL-27(N,A)11-NA-24,,SIG,,FIS) 2022900200003 DETECTOR (NAICR) Calibrated sodium-iodine crystal 2022900200004 DECAY-DATA (11-NA-24,15.05HR) 2022900200005 MONITOR Standard sources used for calibrating the Na-I crystal 2022900200006 see EANDC(E)-57,p.70. 2022900200007 HISTORY (20230130A) SD: Data updated according to presentation 2022900200008 in the table. Value from col.HL -> DECAY-DATA. 2022900200009 ENDBIB 7 0 2022900200010 NOCOMMON 0 0 2022900200011 DATA 2 1 2022900200012 DATA DATA-ERR 2022900200013 MB MB 2022900200014 0.78 0.03 2022900200015 ENDDATA 3 0 2022900200016 ENDSUBENT 15 0 2022900299999 SUBENT 20229003 20230130 20231011 2022900300001 BIB 5 6 2022900300002 REACTION (16-S-32(N,P)15-P-32,,SIG,,FIS) 2022900300003 DETECTOR (D4PI) 2022900300004 MONITOR Absolute. 2022900300005 PART-DET (B-) 2022900300006 HISTORY (20230130A) SD: Data updated according to presentation 2022900300007 in the table. 2022900300008 ENDBIB 6 0 2022900300009 NOCOMMON 0 0 2022900300010 DATA 2 1 2022900300011 DATA DATA-ERR 2022900300012 MB MB 2022900300013 74. 3.0 2022900300014 ENDDATA 3 0 2022900300015 ENDSUBENT 14 0 2022900399999 SUBENT 20229004 20230130 20231011 2022900400001 BIB 6 8 2022900400002 REACTION (49-IN-115(N,G)49-IN-116-M1+M2,,SIG,,FIS) 2022900400003 DETECTOR (NAICR) 2022900400004 DECAY-DATA (49-IN-116-M1,54.MIN,DG) 2022900400005 MONITOR (49-IN-115(N,G)49-IN-116-M1+M2,,SIG) 2022900400006 MONIT-REF (,P.P.Damle+,R,BLG-421,1967) 2022900400007 HISTORY (20230130A) SD: Data updated according to presentation 2022900400008 in the table. Value from col.HL -> DECAY-DATA. 2022900400009 SF4=In-115m -> In-116m1+m2 in REACTION code. 2022900400010 ENDBIB 8 0 2022900400011 NOCOMMON 0 0 2022900400012 DATA 4 1 2022900400013 MONIT MONIT-ERR DATA DATA-ERR 2022900400014 B B MB MB 2022900400015 159. 4. 122. 6. 2022900400016 ENDDATA 3 0 2022900400017 ENDSUBENT 16 0 2022900499999 SUBENT 20229005 20230130 20231011 2022900500001 BIB 5 7 2022900500002 REACTION (49-IN-115(N,INL)49-IN-115-M,,SIG,,FIS) 2022900500003 DECAY-DATA (49-IN-115-M,4.5HR,DG) 2022900500004 DETECTOR (NAICR) Calibrated sodium-iodine crystal 2022900500005 MONITOR Standard sources used for calibrating the Na-I crystal2022900500006 see EANDC(E)-57,p.70. 2022900500007 HISTORY (20230130A) SD: Data updated according to presentation 2022900500008 in the table. Value from col.HL -> DECAY-DATA. 2022900500009 ENDBIB 7 0 2022900500010 NOCOMMON 0 0 2022900500011 DATA 2 1 2022900500012 DATA DATA-ERR 2022900500013 MB MB 2022900500014 200. 10. 2022900500015 ENDDATA 3 0 2022900500016 ENDSUBENT 15 0 2022900599999 SUBENT 20229006 20230130 20231011 2022900600001 BIB 5 7 2022900600002 REACTION (79-AU-197(N,G)79-AU-198,,SIG,,FIS) 2022900600003 DETECTOR (NAICR) Calibrated sodium-iodine crystal 2022900600004 MONITOR Standard sources used for calibrating the Na-I crystal 2022900600005 see EANDC(E)-57,p.70. 2022900600006 PART-DET (DG) Decay gammas 2022900600007 HISTORY (20230130A) SD: Data updated according to presentation 2022900600008 in the table. 2022900600009 ENDBIB 7 0 2022900600010 NOCOMMON 0 0 2022900600011 DATA 2 1 2022900600012 DATA DATA-ERR 2022900600013 MB MB 2022900600014 74. 3. 2022900600015 ENDDATA 3 0 2022900600016 ENDSUBENT 15 0 2022900699999 ENDENTRY 6 0 2022999999999